Assistive Listening Knowledge Base

Data

Latency

Reported latency values and ranges, with signal paths, timing quantities, methods, configurations and source qualifications.

  • 336 rows
  • 32 sources
  • Compiled 13 October 2026
  • Updated 14 October 2026
  • Version 2.1
  • Source dates: June 2016 – 16 September 2026; 2 undated sources

Data licence: CC0 1.0 (public domain dedication).

Download CSV Download JSON

Reading the results

Rows retain measured or stated values, ranges and study summaries for their named paths or timing quantities. Compare the metric, scope, evidence and endpoints before comparing values. For broadcast reception, Presentation Delay is one component of total system delay, set by the transmitter and applied at the receiver. General network round-trip times are a different measure. Repeated readings, summaries and configurations can overlap, so rows must not be pooled into a technology average. Dates retain their stated basis and precision. (Bluetooth SIG Generic Audio Working… 2026; Sui et al. 2016; Pro Audito Schweiz 2025)

Column definitions · Compilation and interpretation · Change log

Latency by path

One mark per row: filled means measured; hollow means stated. Each technology has its own shape and colour, with a text label. Select a mark to read its source, configuration and limits in the table.

A range has a line, with its mark at the first endpoint; no midpoint is calculated. Bounds are marked at the reported number. Qualifiers stay visible: ~ means approximate, < means less than, <= means up to, and > means greater than or an open upper end (+). Best-case and open-ended wording is kept beside its mark.

Metrics have separate scales. Rows may overlap or use different methods and endpoints; they are never pooled. Measured does not mean independent. On narrow screens, scroll each plot horizontally. Skip to the full table.

Path latency

Linear scale: 0 to 600 ms. This scale stays fixed when filtering.

HA1 acoustic input to output

HA2 acoustic input to output

RM1 plus HA1

RM2 plus HA2

Auri TX2N / TX2N-D to Auri RX1

Bettear CASTER streaming path; receiver unspecified

Auracast: typical system path

Hearing loops: typical system path

Infrared: typical system path

RF/FM: typical system path

Wi-Fi streaming: typical system path

Audio over Wi-Fi: typical system path

AirPods onboard microphone through unnamed iPhone app to AirPods

Jacoti ListenApp to AirPods

Lightning EarPods microphone through Jacoti ListenApp to wired EarPods

iPhone microphone 1 through unnamed app to AirPods

iPhone microphone 2 through unnamed app to AirPods

Auracast through headphones or hearing aids (often)

Auracast transmitter to receiver (best cases)

ListenWiFi PL-900 / PL-301 to Android mobile devices

ListenWiFi PL-900 / PL-301 to Apple mobile devices

ListenWIFI server to LWR-1050 receiver

Proprietary Wi-Fi device to phone to hearing aid

Opus AuraGate streaming path; receiver unspecified

Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0

Row 46: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 74 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA10. Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 46 · 74 ms · measured Auracast Row 55: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 55 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AB10. Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 55 · 55 ms · measured Auracast Row 66: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 75 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AC10. Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 66 · 75 ms · measured Auracast Row 278: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 38 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!X10. Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 278 · 38 ms · measured Auracast Row 285: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 70 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y10. Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 285 · 70 ms · measured Auracast Row 286: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 73 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y10 comment. Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 286 · 73 ms · measured Auracast Row 297: Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0; 41 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z10. Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 297 · 41 ms · measured Auracast 0200400600ms

Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Row 47: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 73 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA11. Sample rate/mode: 24 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 47 · 73 ms · measured Auracast Row 56: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 55 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AB11. Sample rate/mode: 48 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 56 · 55 ms · measured Auracast Row 67: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 75 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AC11. Sample rate/mode: 48 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 67 · 75 ms · measured Auracast Row 279: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 38 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!X11. Sample rate/mode: 16 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 279 · 38 ms · measured Auracast Row 287: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 69 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y11. Sample rate/mode: 16 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 287 · 69 ms · measured Auracast Row 288: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 72 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y11 comment. Sample rate/mode: 16 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 288 · 72 ms · measured Auracast Row 298: Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5; 40 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z11. Sample rate/mode: 24 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 298 · 40 ms · measured Auracast 0200400600ms

Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Row 48: Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra; 75 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA12. Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 48 · 75 ms · measured Auracast Row 57: Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra; 57 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AB12. Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 57 · 57 ms · measured Auracast Row 68: Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra; 77 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AC12. Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 68 · 77 ms · measured Auracast Row 280: Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra; 42 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!X12. Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 280 · 42 ms · measured Auracast Row 289: Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra; 74 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y12. Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 289 · 74 ms · measured Auracast Row 299: Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra; 42 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z12. Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 299 · 42 ms · measured Auracast 0200400600ms

Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Row 49: Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3; 170 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA14. Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 49 · 170 ms · measured Auracast Row 58: Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3; 127 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AB14. Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 58 · 127 ms · measured Auracast Row 69: Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3; 147 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AC14. Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 69 · 147 ms · measured Auracast Row 281: Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3; 110 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!X14. Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 281 · 110 ms · measured Auracast Row 290: Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3; 172 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y14. Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 290 · 172 ms · measured Auracast Row 300: Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3; 108 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z14. Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 300 · 108 ms · measured Auracast 0200400600ms

Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3

Row 50: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 44 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA5. Sample rate/mode: 24 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 50 · 44 ms · measured Auracast Row 51: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 45 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA5 comment. Sample rate/mode: 24 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 51 · 45 ms · measured Auracast Row 52: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 53 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA5 comment. Sample rate/mode: 24 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 52 · 53 ms · measured Auracast Row 64: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 39 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AB5. Sample rate/mode: 48 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 64 · 39 ms · measured Auracast Row 65: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 39-52 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AB5 comment. Sample rate/mode: 48 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 65 · 39-52 ms · measured Auracast Row 75: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 71 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AC5. Sample rate/mode: 48 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 75 · 71 ms · measured Auracast Row 76: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 42-71 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AC5 comment. Sample rate/mode: 48 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 76 · 42-71 ms · measured Auracast Row 282: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 32 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!X5. Sample rate/mode: 16 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 282 · 32 ms · measured Auracast Row 291: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 42 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y5. Sample rate/mode: 16 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 291 · 42 ms · measured Auracast Row 292: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 45 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y5 comment. Sample rate/mode: 16 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 292 · 45 ms · measured Auracast Row 293: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 54 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y5 comment. Sample rate/mode: 16 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 293 · 54 ms · measured Auracast Row 294: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 60 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y5 comment. Sample rate/mode: 16 HR kHz; input: electrical; output: electrical. Read the table row for method and limitations. 294 · 60 ms · measured Auracast Row 301: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 31 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z5. Sample rate/mode: 24 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 301 · 31 ms · measured Auracast Row 302: Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3; 31-42 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z5 comment. Sample rate/mode: 24 LL kHz; input: electrical; output: electrical. Read the table row for method and limitations. 302 · 31-42 ms · measured Auracast 0200400600ms

Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Row 53: Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12; 102 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AA7. Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 53 · 102 ms · measured Auracast Row 283: Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12; 69 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!X7. Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 283 · 69 ms · measured Auracast Row 295: Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12; 101 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Y7. Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 295 · 101 ms · measured Auracast Row 303: Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12; 70 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!Z7. Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic. Read the table row for method and limitations. 303 · 70 ms · measured Auracast 0200400600ms

Arendi TV-Streamer FW:0.8.1 to Starkey Edge hearing aid

JBL Tour Pro 3 Case FW:4.6.5 to Humantechnik earis MAX Headphone FW: 4.4.0

JBL Tour Pro 3 Case FW:4.6.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

JBL Tour Pro 3 Case FW:4.6.5 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3

Row 80: JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3; 52 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AD5. Sample rate/mode: 16 SQ kHz; input: electrical; output: electrical. Read the table row for method and limitations. 80 · 52 ms · measured Auracast Row 81: JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3; 52-85 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AD5 comment. Sample rate/mode: 16 SQ kHz; input: electrical; output: electrical. Read the table row for method and limitations. 81 · 52-85 ms · measured Auracast Row 88: JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3; 58 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AE5. Sample rate/mode: 48 HQ kHz; input: electrical; output: electrical. Read the table row for method and limitations. 88 · 58 ms · measured Auracast Row 89: JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3; 58-83 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AE5 comment. Sample rate/mode: 48 HQ kHz; input: electrical; output: electrical. Read the table row for method and limitations. 89 · 58-83 ms · measured Auracast 0200400600ms

JBL Tour Pro 3 Case FW:4.6.5 to Starkey Edge hearing aid

JBL Tour Pro 3 Case FW:4.6.5 to JBL Tour Pro 3 FW:4.9.5

JBL Tour Pro 3 Case FW:4.6.5 to Samsung Buds Pro 3 FW:R630XXU0AYG3

JBL Tour Pro 3 Case FW:4.6.5 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Moer Moor Duo FW:3.7.0 to Humantechnik earis MAX Headphone FW: 4.4.0

Moer Moor Duo FW:3.7.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Moer Moor Duo FW:3.7.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Moer Moor Duo FW:3.7.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Moer Moor Duo FW:3.7.0 to Bettear RTX FW:1.0.1 & 1.0.3

Moor Moer SoundLinker FW:5.2.2 to Humantechnik earis MAX Headphone FW: 4.4.0

Moor Moer SoundLinker FW:5.2.2 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Moor Moer SoundLinker FW:5.2.2 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Moor Moer SoundLinker FW:5.2.2 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3

Row 102: Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3; 26 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AG5. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 102 · 26 ms · measured Auracast Row 103: Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3; 26-47 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AG5 comment. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 103 · 26-47 ms · measured Auracast Row 111: Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3; 26 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AH5. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 111 · 26 ms · measured Auracast Row 112: Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3; 27 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AH5 comment. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 112 · 27 ms · measured Auracast Row 113: Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3; 28 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AH5 comment. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 113 · 28 ms · measured Auracast Row 119: Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3; 28 ms; measured; Auracast; path latency; shared-path evidence; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!AI5. Sample rate/mode: 24 kHz; input: acoustic; output: electrical. Read the table row for method and limitations. 119 · 28 ms · measured Auracast 0200400600ms

Moor Moer SoundLinker FW:5.2.2 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Moor Moer SoundLinker FW:5.2.2 to Starkey Edge hearing aid

Moor Moer SoundLinker FW:5.2.2 to JBL Tour Pro 3 FW:4.9.5

Listen Auri TX2N FW:1.5 to Humantechnik earis MAX Headphone FW: 4.4.0

Listen Auri TX2N FW:1.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Listen Auri TX2N FW:1.5 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Listen Auri TX2N FW:1.5 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Listen Auri TX2N FW:1.5 to Listen Auri RX1 FW:1.5

Listen Auri TX2N FW:1.5 to Bettear RTX FW:1.0.1 & 1.0.3

Listen Auri TX2N FW:1.5 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Listen Auri TX2N FW:1.5 to JBL Tour Pro 3 FW:4.9.5

Opus Auragate FW:2.1.0 to Humantechnik earis MAX Headphone FW: 4.4.0

Opus Auragate FW:2.1.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Opus Auragate FW:2.1.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Opus Auragate FW:2.1.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Opus Auragate FW:2.1.0 to Bettear RTX FW:1.0.1 & 1.0.3

Opus Auragate FW:2.1.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Opus Auragate FW:2.1.0 to Starkey Edge hearing aid

Bettear B-CASTER FW:1.0.3 to Humantechnik earis MAX Headphone FW: 4.4.0

Bettear B-CASTER FW:1.0.3 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Bettear B-CASTER FW:1.0.3 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Bettear B-CASTER FW:1.0.3 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3

Row 168: Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3; 33 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!H5. Sample rate/mode: 16 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 168 · 33 ms · measured Auracast Row 169: Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3; 41 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!H5 comment. Sample rate/mode: 16 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 169 · 41 ms · measured Auracast Row 176: Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3; 34 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!I5. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 176 · 34 ms · measured Auracast Row 177: Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3; 41 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!I5 comment. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 177 · 41 ms · measured Auracast Row 184: Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3; 36 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!J5. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 184 · 36 ms · measured Auracast Row 185: Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3; 43 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!J5 comment. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 185 · 43 ms · measured Auracast 0200400600ms

Bettear B-CASTER FW:1.0.3 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Bettear B-CASTER FW:1.0.3 to Starkey Edge hearing aid

William Infinium FW:1.4.0 to Humantechnik earis MAX Headphone FW: 4.4.0

William Infinium FW:1.4.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

William Infinium FW:1.4.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

William Infinium FW:1.4.0 to Moor Moer hearClear

William Infinium FW:1.4.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3

William Infinium FW:1.4.0 to Bettear RTX FW:1.0.1 & 1.0.3

William Infinium FW:1.4.0 to Williams Infinium Rx FW:?

William Infinium FW:1.4.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

William Infinium FW:1.4.0 to Starkey Edge hearing aid

Bettear RTX FW:1.0.1 to Humantechnik earis MAX Headphone FW: 4.4.0

Bettear RTX FW:1.0.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Bettear RTX FW:1.0.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Bettear RTX FW:1.0.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Bettear RTX FW:1.0.1 to Bettear RTX FW:1.0.1 & 1.0.3

Bettear RTX FW:1.0.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Opus AurOEM & AurLoop FW:2.0.0 to Humantechnik earis MAX Headphone FW: 4.4.0

Opus AurOEM & AurLoop FW:2.0.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Opus AurOEM & AurLoop FW:2.0.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Opus AurOEM & AurLoop FW:2.0.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3

Row 217: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 88 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!N5. Sample rate/mode: 16 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 217 · 88 ms · measured Auracast Row 224: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 49 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!O5. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 224 · 49 ms · measured Auracast Row 225: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 37 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!O5 comment. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 225 · 37 ms · measured Auracast Row 226: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 39 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!O5 comment. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 226 · 39 ms · measured Auracast Row 227: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 58 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!O5 comment. Sample rate/mode: 24 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 227 · 58 ms · measured Auracast Row 234: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 39 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!P5. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 234 · 39 ms · measured Auracast Row 235: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 37 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!P5 comment. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 235 · 37 ms · measured Auracast Row 236: Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3; 58 ms; measured; Auracast; path latency; venue system; 2025-08-25/2025-09-05; Independent; pro-audito-2025-compat; Latencies - values!P5 comment. Sample rate/mode: 48 kHz; input: electrical; output: electrical. Read the table row for method and limitations. 236 · 58 ms · measured Auracast 0200400600ms

Opus AurOEM & AurLoop FW:2.0.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Opus AurOEM & AurLoop FW:2.0.0 to Starkey Edge hearing aid

GN TV-Streamer + FW:1.0.2.7 to Humantechnik earis MAX Headphone FW: 4.4.0

GN TV-Streamer + FW:1.0.2.7 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

GN TV-Streamer + FW:1.0.2.7 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

GN TV-Streamer + FW:1.0.2.7 to Samsung Buds Pro 3 FW:R630XXU0AYG3

GN TV-Streamer + FW:1.0.2.7 to Bettear RTX FW:1.0.1 & 1.0.3

GN TV-Streamer + FW:1.0.2.7 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

GN TV-Streamer + FW:1.0.2.7 to Starkey Edge hearing aid

GN TV-Streamer + FW:1.0.2.7 to JBL Tour Pro 3 FW:4.9.5

GN MultiMic+ FW:1.0.2.7 to Humantechnik earis MAX Headphone FW: 4.4.0

GN MultiMic+ FW:1.0.2.7 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

GN MultiMic+ FW:1.0.2.7 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

GN MultiMic+ FW:1.0.2.7 to Samsung Buds Pro 3 FW:R630XXU0AYG3

GN MultiMic+ FW:1.0.2.7 to Bettear RTX FW:1.0.1 & 1.0.3

GN MultiMic+ FW:1.0.2.7 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

GN MultiMic+ FW:1.0.2.7 to Starkey Edge hearing aid

GN MultiMic+ FW:1.0.2.7 to JBL Tour Pro 3 FW:4.9.5

Starkey TV-Streamer to Humantechnik earis MAX Headphone FW: 4.4.0

Starkey TV-Streamer to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Starkey TV-Streamer to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Starkey TV-Streamer to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Starkey TV-Streamer to Starkey Edge hearing aid

Starkey TV-Streamer to JBL Tour Pro 3 FW:4.9.5

Humantechnik EarisMAX Transmitter FW:3.6.6 to Humantechnik earis MAX Headphone FW: 4.4.0

Humantechnik EarisMAX Transmitter FW:3.6.6 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Humantechnik EarisMAX Transmitter FW:3.6.6 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Humantechnik EarisMAX Transmitter FW:3.6.6 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Humantechnik EarisMAX Transmitter FW:3.6.6 to Bettear RTX FW:1.0.1 & 1.0.3

Humantechnik EarisMAX Transmitter FW:3.6.6 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12

Humantechnik EarisMAX Transmitter FW:3.6.6 to Starkey Edge hearing aid

Humantechnik EarisMAX Transmitter FW:3.6.6 to JBL Tour Pro 3 FW:4.9.5

Auracast transmitter to receiver

Talker through audio system and Auracast to listener

Transmitter to GN ReSound Nexia hearing aids

Transmitter to neckloop receivers

Accessify over 5G streaming

Auracast transmitter to hearing aid

FM system

Avantree Oasis Aura to AuraClip

Avantree Oasis Aura to fastest tested receiver; model unspecified

Avantree Oasis Aura to hearing aids

MobileConnect stream to phone app

MobileConnect Audience Mic return path

MobileConnect unicast stream

MobileConnect unicast hearing-assistance stream

Auracast transmission

Wi-Fi listening system to standard smartphones

Infinium system to BA R1 receiver

Component latency

Linear scale: 0 to 80 ms. This scale stays fixed when filtering.

Auri TX2N / TX2N-D line input to line output

Auri TX2N to another TX2N over multicast RTP

Bluetooth audio link: generic added latency

LE Audio buffered fault to detectable output effect

Venue audio system before Auracast

Audio system plus airborne path to distant directional microphone

Timing parameter

Linear scale: 0 to 3000 ms. This scale stays fixed when filtering.

Broadcast receiver Presentation Delay

Broadcast transport: 16/24 kHz low-latency settings

Broadcast transport: 16/24 kHz high-reliability settings

All Auracast receivers: Presentation Delay support

HAP/TMAP receivers: Presentation Delay support

ListenWiFi PL-900 added audio delay

ListenWIFI added delay per input

Simple transmitter example: Presentation Delay

Study summary

Linear scale: 0 to 300 ms. This scale stays fixed when filtering.

Auracast transmitters to hearing aids and earbuds; models unspecified

Professional installation transmitter to hearing aid: highest result

Professional installation transmitters: lowest result at 16 kHz

All tested transmitter-receiver pairs

Acoustic travel time

Linear scale: 0 to 200 ms. This scale stays fixed when filtering.

Airborne sound over about 10 m

Loudspeaker sound over about 60 m

Stage to balcony microphone (unaccounted acoustic delay)

Loudspeakers through air to listeners

Video latency

Linear scale: 0 to 100 ms. This scale stays fixed when filtering.

Source-generated picture to television display (some televisions)

Latency change

Linear scale: -10 to 30 ms. This scale stays fixed when filtering.

Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0

Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5

Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 Ultra

Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3

Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3

AurOEM/AuraLoop at 16 kHz: firmware 2.0.0 relative to 1.2.0

Relative arrival offset

Linear scale: 0 to 400 ms. This scale stays fixed when filtering.

Auri RX1 output relative to loudspeaker sound at rear seat

Accessify over 5G relative to airborne sound

Auracast hearing aid relative to airborne sound

Auracast receiver relative to airborne sound

FM relative to airborne sound

Network round-trip time

Linear scale: 0 to 300 ms. This scale stays fixed when filtering.

Tsinghua campus Wi-Fi hop (90th percentile of one-minute average round-trip time)

Tsinghua campus Wi-Fi hop (99th percentile of one-minute average round-trip time)

Tsinghua campus Wi-Fi hop (median of one-minute average round-trip time)

Scroll horizontally to read all columns. Empty cells mean no value was recorded; read each row’s notes and limits with its results.

Latency — 336 rows
System pathTechnologyScopeMetricLatency msEvidenceMethodDateDate basisSource IDSource locatorConfigurationNotesFunding detailFundingLimitationsRow ID
HA1 acoustic input to outputSharedshared-path evidencepath latency~6-7measuredSemi-anechoic chamber; 5-cycle tone bursts at 750/1500/3000 Hz and 70 dB SPL; reference microphone versus 2 cc coupler output; two compression settings.2025-09-25source dateandreatta-2025Section 3.1Two personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping.Independent (IRCCS Burlo Garofolo, a public research hospital, Ricerca Corrente project); two authors employed by Acustica CaregnatoIndependentTwo personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping. andreatta-2025: Two proprietary systems, not Auracast; idealised semi-anechoic conditions; no listener testing.latency-0001
HA2 acoustic input to outputSharedshared-path evidencepath latency~5-7measuredSemi-anechoic chamber; 5-cycle tone bursts at 750/1500/3000 Hz and 70 dB SPL; reference microphone versus 2 cc coupler output; two compression settings.2025-09-25source dateandreatta-2025Section 3.1Two personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping.Independent (IRCCS Burlo Garofolo, a public research hospital, Ricerca Corrente project); two authors employed by Acustica CaregnatoIndependentTwo personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping. andreatta-2025: Two proprietary systems, not Auracast; idealised semi-anechoic conditions; no listener testing.latency-0002
RM1 plus HA1Sharedshared-path evidencepath latency~23-24measuredSemi-anechoic chamber; 5-cycle tone bursts at 750/1500/3000 Hz and 70 dB SPL; reference microphone versus 2 cc coupler output; two compression settings.2025-09-25source dateandreatta-2025Section 3.1Two personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping.Independent (IRCCS Burlo Garofolo, a public research hospital, Ricerca Corrente project); two authors employed by Acustica CaregnatoIndependentTwo personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping. andreatta-2025: Two proprietary systems, not Auracast; idealised semi-anechoic conditions; no listener testing.latency-0003
RM2 plus HA2Sharedshared-path evidencepath latency~33-35measuredSemi-anechoic chamber; 5-cycle tone bursts at 750/1500/3000 Hz and 70 dB SPL; reference microphone versus 2 cc coupler output; two compression settings.2025-09-25source dateandreatta-2025Section 3.1Two personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping.Independent (IRCCS Burlo Garofolo, a public research hospital, Ricerca Corrente project); two authors employed by Acustica CaregnatoIndependentTwo personal remote-microphone/hearing-aid pairs, no listeners; shared processing-path evidence only, not a venue system or Auracast. Source labels retained to avoid inferring model mapping. andreatta-2025: Two proprietary systems, not Auracast; idealised semi-anechoic conditions; no listener testing.latency-0004
Auri TX2N / TX2N-D line input to line outputAuracastvenue systemcomponent latency13statedNo measurement method reported.2025-07source dateauri-2025-tx2n-datasheetAudio Performance / Network audio inputManufacturer specification. System range depends on sample rate and mono/stereo; network value is nominal; other receivers vary.Manufacturer (Listen Technologies and Ampetronic)ManufacturerManufacturer specification. System range depends on sample rate and mono/stereo; network value is nominal; other receivers vary. auri-2025-tx2n-datasheet: Manufacturer specifications, not independent measurements. Latency through hearing aids, phones or other receivers is not given.latency-0005
Auri TX2N / TX2N-D to Auri RX1Auracastvenue systempath latency29-45statedNo measurement method reported.2025-07source dateauri-2025-tx2n-datasheetp. 2, Audio Processing: Latency (complete system, end to end)Manufacturer specification. The 29-45 ms TX2N-to-RX1 range depends on sample rate and mono/stereo; other receivers vary.Manufacturer (Listen Technologies and Ampetronic)ManufacturerManufacturer specification. The 29-45 ms TX2N-to-RX1 range depends on sample rate and mono/stereo; other receivers vary. auri-2025-tx2n-datasheet: Manufacturer specifications, not independent measurements. Latency through hearing aids, phones or other receivers is not given.latency-0006
Auri TX2N to another TX2N over multicast RTPAuracastvenue systemcomponent latency5statedNo measurement method reported.2025-07source dateauri-2025-tx2n-datasheetAudio Performance / Network audio inputManufacturer specification. System range depends on sample rate and mono/stereo; network value is nominal; other receivers vary.Manufacturer (Listen Technologies and Ampetronic)ManufacturerManufacturer specification. System range depends on sample rate and mono/stereo; network value is nominal; other receivers vary. auri-2025-tx2n-datasheet: Manufacturer specifications, not independent measurements. Latency through hearing aids, phones or other receivers is not given.latency-0007
Bettear CASTER streaming path; receiver unspecifiedAuracastvenue systempath latency<40statedNo measurement method reported.2026source datebettear-2026-caster-manualHighlightsFirmware 1.0.8Manufacturer statement; endpoints and receiver unspecified.Manufacturer (Bettear)ManufacturerManufacturer statement; endpoints and receiver unspecified. bettear-2026-caster-manual: Manufacturer documentation for one firmware version. It gives no range, coverage or test data, and does not say which receiver the latency figure applies to.latency-0008
Broadcast receiver Presentation DelayAuracastvenue systemtiming parameter40statedNo measurement method reported.2026-06-23source datebluetooth-sig-2026-bapTable 6.4 and note 4Specification value; transport entries are maximum transport latency. Presentation Delay is only part of total system delay, not measured end-to-end latency.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodySpecification value; transport entries are maximum transport latency. Presentation Delay is only part of total system delay, not measured end-to-end latency. bluetooth-sig-2026-bap: Defines what devices must support, not how a venue system is set up or measured.latency-0009
Broadcast transport: 16/24 kHz low-latency settingsAuracastvenue systemtiming parameter10statedNo measurement method reported.2026-06-23source datebluetooth-sig-2026-bapTable 6.4: 16_2_1 / 24_2_1Specification value; transport entries are maximum transport latency. Presentation Delay is only part of total system delay, not measured end-to-end latency. These settings are mandatory for receivers; transmitter support for 24 kHz is conditional, unlike 16 kHz.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodySpecification value; transport entries are maximum transport latency. Presentation Delay is only part of total system delay, not measured end-to-end latency. These settings are mandatory for receivers; transmitter support for 24 kHz is conditional, unlike 16 kHz. bluetooth-sig-2026-bap: Defines what devices must support, not how a venue system is set up or measured.latency-0010
Broadcast transport: 16/24 kHz high-reliability settingsAuracastvenue systemtiming parameter60statedNo measurement method reported.2026-06-23source datebluetooth-sig-2026-bapTable 6.4: 16_2_2 / 24_2_2Specification value; transport entries are maximum transport latency. Presentation Delay is only part of total system delay, not measured end-to-end latency. These settings are mandatory for receivers; transmitter support for 24 kHz is conditional, unlike 16 kHz.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodySpecification value; transport entries are maximum transport latency. Presentation Delay is only part of total system delay, not measured end-to-end latency. These settings are mandatory for receivers; transmitter support for 24 kHz is conditional, unlike 16 kHz. bluetooth-sig-2026-bap: Defines what devices must support, not how a venue system is set up or measured.latency-0011
All Auracast receivers: Presentation Delay supportAuracastvenue systemtiming parameter40statedNo measurement method reported.2026-09-16source datebluetooth-sig-2026-transmitter-howtoPresentation delayDesign guidance about supported timing values, not end-to-end latency.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodyDesign guidance about supported timing values, not end-to-end latency. bluetooth-sig-2026-transmitter-howto: Design guidance for manufacturers. The airtime figures are the SIG's calculations for one stream on the 2M PHY, not measurements. The cover gives 16 September 2026 and the version history 14 September 2026.latency-0012
HAP/TMAP receivers: Presentation Delay supportAuracastvenue systemtiming parameter20-40statedNo measurement method reported.2026-09-16source datebluetooth-sig-2026-transmitter-howtoPresentation delayDesign guidance about supported timing values, not end-to-end latency.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodyDesign guidance about supported timing values, not end-to-end latency. bluetooth-sig-2026-transmitter-howto: Design guidance for manufacturers. The airtime figures are the SIG's calculations for one stream on the 2M PHY, not measurements. The cover gives 16 September 2026 and the version history 14 September 2026.latency-0013
Auracast transmitters to hearing aids and earbuds; models unspecifiedAuracastvenue systemstudy summary>40measuredStreaming latency experiment; timing method not given in synopsis.2026-08source datebruce-2026Abstract: first experimentAll measured combinations exceed the cited 25-40 ms target. Device count and funding grant not reported; KEMAR applies to the separate level experiment.Independent (McMaster University with SoundsGood Labs, which the synopsis does not describe; no funding statement in the synopsis)IndependentAll measured combinations exceed the cited 25-40 ms target. Device count and funding grant not reported; KEMAR applies to the separate level experiment. bruce-2026: Conference synopsis; device models, number of devices and full data not listed. Output level was measured with earbuds only, not hearing aids.latency-0014
Auracast transmitters to hearing aids and earbuds; models unspecifiedAuracastvenue systemstudy summary>80measuredStreaming latency experiment; timing method not given in synopsis.2026-08source datebruce-2026Abstract: first experimentSome combinations exceed 80 ms; these are a subset of the same study. Device count and funding grant not reported; KEMAR applies to the separate level experiment.Independent (McMaster University with SoundsGood Labs, which the synopsis does not describe; no funding statement in the synopsis)IndependentSome combinations exceed 80 ms; these are a subset of the same study. Device count and funding grant not reported; KEMAR applies to the separate level experiment. bruce-2026: Conference synopsis; device models, number of devices and full data not listed. Output level was measured with earbuds only, not hearing aids.latency-0015
Auracast: typical system pathAuracastvenue systempath latency~36-100+statedNo measurement method reported.2025-10-29source datecha-2025-als-quick-guideComparison grid: Latency rowAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible.Nonprofit advocacy (Center for Hearing Access, an initiative of The John G. Shedd Institute for the Arts; it states that it accepts no donations from hearing-related vendors)Nonprofit advocacyAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible. cha-2025-als-quick-guide: A summary chart: the latency ranges are not linked to specific measurements. The guide states that consumers prefer hearing loops, so it reflects the publisher's advocacy position.latency-0016
Hearing loops: typical system pathHearing loopsvenue systempath latency~1-20statedNo measurement method reported.2025-10-29source datecha-2025-als-quick-guideComparison grid: Latency rowAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible.Nonprofit advocacy (Center for Hearing Access, an initiative of The John G. Shedd Institute for the Arts; it states that it accepts no donations from hearing-related vendors)Nonprofit advocacyAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible. cha-2025-als-quick-guide: A summary chart: the latency ranges are not linked to specific measurements. The guide states that consumers prefer hearing loops, so it reflects the publisher's advocacy position.latency-0017
Infrared: typical system pathInfraredvenue systempath latency~1-20statedNo measurement method reported.2025-10-29source datecha-2025-als-quick-guideComparison grid: Latency rowAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible.Nonprofit advocacy (Center for Hearing Access, an initiative of The John G. Shedd Institute for the Arts; it states that it accepts no donations from hearing-related vendors)Nonprofit advocacyAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible. cha-2025-als-quick-guide: A summary chart: the latency ranges are not linked to specific measurements. The guide states that consumers prefer hearing loops, so it reflects the publisher's advocacy position.latency-0018
RF/FM: typical system pathRF/FMvenue systempath latency~1-30statedNo measurement method reported.2025-10-29source datecha-2025-als-quick-guideComparison grid: Latency rowAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible.Nonprofit advocacy (Center for Hearing Access, an initiative of The John G. Shedd Institute for the Arts; it states that it accepts no donations from hearing-related vendors)Nonprofit advocacyAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible. cha-2025-als-quick-guide: A summary chart: the latency ranges are not linked to specific measurements. The guide states that consumers prefer hearing loops, so it reflects the publisher's advocacy position.latency-0019
Wi-Fi streaming: typical system pathWi-Fi streamingvenue systempath latency~200-300+statedNo measurement method reported.2025-10-29source datecha-2025-als-quick-guideComparison grid: Latency rowAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible.Nonprofit advocacy (Center for Hearing Access, an initiative of The John G. Shedd Institute for the Arts; it states that it accepts no donations from hearing-related vendors)Nonprofit advocacyAdvocacy estimates; no test protocol or model list. Plus sign means longer values are possible. cha-2025-als-quick-guide: A summary chart: the latency ranges are not linked to specific measurements. The guide states that consumers prefer hearing loops, so it reflects the publisher's advocacy position.latency-0020
Audio over Wi-Fi: typical system pathWi-Fi streamingvenue systempath latency100-500+statedNo measurement method reported.undatedundated sourcecha-2026-wifiLatency sectionAdvocacy estimate; no test protocol, phones or networks identified; differs from the same organisation's quick guide.Nonprofit advocacy (Center for Hearing Access, an initiative of The John G. Shedd Institute for the Arts; it asks for donations and states that it accepts none from hearing-related vendors)Nonprofit advocacyAdvocacy estimate; no test protocol, phones or networks identified; differs from the same organisation's quick guide. cha-2026-wifi: An advocacy page with no measurements: the latency range is not linked to any test, phone or network, and the Center's October 2025 quick guide gives 200-300+ ms for the same technology. The Center's site labels hearing loops "Consumer Preferred", so the page reflects its advocacy position. The page carries no date (copyright 2024-2026).latency-0021
Bluetooth audio link: generic added latencySharedshared-path evidencecomponent latency60-80+statedNo measurement method reported.2017-09-22source dateeinhorn-2017Latency and Hearing AidsManufacturer-associated article; generic statement, not isolated measurement of a phone-to-hearing-aid link.Manufacturer (the measurements are Jacoti's, a maker of hearing apps, one of which was among those tested; the author states being a consultant for Jacoti and thanks its software team for the data)ManufacturerManufacturer-associated article; generic statement, not isolated measurement of a phone-to-hearing-aid link. einhorn-2017: A maker's own measurements, reported by its consultant, with no stated method, repetitions or iOS version; the tests use phone or earbud microphones through a phone app, with different apps and input microphones across conditions, not from a venue's Wi-Fi stream. Tested 2016-2017 AirPods; Bluetooth earbuds, phones and hearing-aid streaming have changed since. Published online on 22 September 2017 for the October 2017 issue.latency-0022
AirPods onboard microphone through unnamed iPhone app to AirPodsSharedshared-path evidencepath latency192measuredJacoti bench measurements reported by its consultant; protocol not given.2017-09-22source dateeinhorn-2017Testing an iPhone Hearing App / ConclusionManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices.Manufacturer (the measurements are Jacoti's, a maker of hearing apps, one of which was among those tested; the author states being a consultant for Jacoti and thanks its software team for the data)ManufacturerManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices. einhorn-2017: A maker's own measurements, reported by its consultant, with no stated method, repetitions or iOS version; the tests use phone or earbud microphones through a phone app, with different apps and input microphones across conditions, not from a venue's Wi-Fi stream. Tested 2016-2017 AirPods; Bluetooth earbuds, phones and hearing-aid streaming have changed since. Published online on 22 September 2017 for the October 2017 issue.latency-0023
Jacoti ListenApp to AirPodsSharedshared-path evidencepath latency266measuredJacoti bench measurements reported by its consultant; protocol not given.2017-09-22source dateeinhorn-2017Testing an iPhone Hearing App / ConclusionManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices.Manufacturer (the measurements are Jacoti's, a maker of hearing apps, one of which was among those tested; the author states being a consultant for Jacoti and thanks its software team for the data)ManufacturerManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices. einhorn-2017: A maker's own measurements, reported by its consultant, with no stated method, repetitions or iOS version; the tests use phone or earbud microphones through a phone app, with different apps and input microphones across conditions, not from a venue's Wi-Fi stream. Tested 2016-2017 AirPods; Bluetooth earbuds, phones and hearing-aid streaming have changed since. Published online on 22 September 2017 for the October 2017 issue.latency-0024
Lightning EarPods microphone through Jacoti ListenApp to wired EarPodsSharedshared-path evidencepath latency16measuredJacoti bench measurements reported by its consultant; protocol not given.2017-09-22source dateeinhorn-2017Testing an iPhone Hearing App / ConclusionManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices.Manufacturer (the measurements are Jacoti's, a maker of hearing apps, one of which was among those tested; the author states being a consultant for Jacoti and thanks its software team for the data)ManufacturerManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices. einhorn-2017: A maker's own measurements, reported by its consultant, with no stated method, repetitions or iOS version; the tests use phone or earbud microphones through a phone app, with different apps and input microphones across conditions, not from a venue's Wi-Fi stream. Tested 2016-2017 AirPods; Bluetooth earbuds, phones and hearing-aid streaming have changed since. Published online on 22 September 2017 for the October 2017 issue.latency-0025
iPhone microphone 1 through unnamed app to AirPodsSharedshared-path evidencepath latency295measuredJacoti bench measurements reported by its consultant; protocol not given.2017-09-22source dateeinhorn-2017Testing an iPhone Hearing App / ConclusionManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices.Manufacturer (the measurements are Jacoti's, a maker of hearing apps, one of which was among those tested; the author states being a consultant for Jacoti and thanks its software team for the data)ManufacturerManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices. einhorn-2017: A maker's own measurements, reported by its consultant, with no stated method, repetitions or iOS version; the tests use phone or earbud microphones through a phone app, with different apps and input microphones across conditions, not from a venue's Wi-Fi stream. Tested 2016-2017 AirPods; Bluetooth earbuds, phones and hearing-aid streaming have changed since. Published online on 22 September 2017 for the October 2017 issue.latency-0026
iPhone microphone 2 through unnamed app to AirPodsSharedshared-path evidencepath latency258measuredJacoti bench measurements reported by its consultant; protocol not given.2017-09-22source dateeinhorn-2017Testing an iPhone Hearing App / ConclusionManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices.Manufacturer (the measurements are Jacoti's, a maker of hearing apps, one of which was among those tested; the author states being a consultant for Jacoti and thanks its software team for the data)ManufacturerManufacturer work; personal amplification app, not a venue Wi-Fi test. App versions, repetitions and iOS version unspecified; 2016-2017 devices. einhorn-2017: A maker's own measurements, reported by its consultant, with no stated method, repetitions or iOS version; the tests use phone or earbud microphones through a phone app, with different apps and input microphones across conditions, not from a venue's Wi-Fi stream. Tested 2016-2017 AirPods; Bluetooth earbuds, phones and hearing-aid streaming have changed since. Published online on 22 September 2017 for the October 2017 issue.latency-0027
Auracast through headphones or hearing aids (often)Auracastvenue systempath latency~70statedNo measurement method reported.2026-09source dategraf-2026Latency paragraphExpert guidance; no device list or measurement method. Total value includes receiver processing.Nonprofit advocacy (Pro Audito Schweiz, Swiss hearing-loss association)Nonprofit advocacyExpert guidance; no device list or measurement method. Total value includes receiver processing. graf-2026: Expert guidance based on Swiss practice; no measurement data or method is reported. EN 300 328 allows up to 20 dBm e.i.r.p.; 10 dBm is the level above which its adaptivity or airtime limits apply. Machine-translated from German.latency-0028
Auracast transmitter to receiver (best cases)Auracastvenue systempath latency<40statedNo measurement method reported.2026-09source dategraf-2026Latency paragraphExpert guidance; no device list or measurement method. Total value includes receiver processing.Nonprofit advocacy (Pro Audito Schweiz, Swiss hearing-loss association)Nonprofit advocacyExpert guidance; no device list or measurement method. Total value includes receiver processing. graf-2026: Expert guidance based on Swiss practice; no measurement data or method is reported. EN 300 328 allows up to 20 dBm e.i.r.p.; 10 dBm is the level above which its adaptivity or airtime limits apply. Machine-translated from German.latency-0029
Airborne sound over about 10 mSharedvenue systemacoustic travel time30-40statedNo measurement method reported.2024-11source datehunn-2024-le-audio-bookSection 2.1.1.2Illustrative propagation statement; no system test.Independent (the author's own book; free edition distributed by the Bluetooth SIG; the 2024 Broadcast Audio URI specification lists the author under GN Hearing, a hearing-aid maker)IndependentIllustrative propagation statement; no system test. hunn-2024-le-audio-book: The author's explanations, not a specification. The Broadcast Audio URI specification (2024) lists the author under GN Hearing A/S.latency-0030
Loudspeaker sound over about 60 mSharedvenue systemacoustic travel time~180statedNo measurement method reported.2023-05-03source datekaufmann-2023Section 2.4Illustrative calculation using about 343 m/s; no new measurements.Independent (Arizona State University)IndependentIllustrative calculation using about 343 m/s; no new measurements. kaufmann-2023: No new listening data. The delay-tolerance studies it cites concern a hearing aid's own processing delay, where the device sound arrives after the direct sound, not an assistive signal that arrives before the room sound.latency-0031
LE Audio buffered fault to detectable output effectAuracastshared-path evidencecomponent latency<=60statedNo measurement method reported.2026-02source datelamacchia-2026-audioxpress-testingFigure 21 discussionManufacturer-associated testing guide; illustrative buffering statement, not a measured venue or product latency.Manufacturer (Cloud2GND, maker of the AW100 broadcaster used; HEAD acoustics lent test equipment)ManufacturerManufacturer-associated testing guide; illustrative buffering statement, not a measured venue or product latency. lamacchia-2026-audioxpress-testing: Consumer devices on a bench rather than venue equipment in a room, with few numeric results and no stated total receiver sample or representative venue-device sample. The author's company makes the reference broadcaster.latency-0032
ListenWiFi PL-900 added audio delayWi-Fi streamingvenue systemtiming parameter<=3000statedNo measurement method reported.2017-04-27source datelisten-2017-wifi-latencyAudio DelayManufacturer adjustment capacity, not inherent latency.Manufacturer (Listen Technologies, maker of the ListenWiFi system described)ManufacturerManufacturer adjustment capacity, not inherent latency. listen-2017-wifi-latency: The maker's own figures, without a method: the note does not say which phones or how many were tested, the network load, what the delay was measured between, or whether listening was wired or Bluetooth. It describes the 2017 system (PL-900 server and PL-301 access point), so later Listen systems may differ, and it addresses TV viewing rather than live speech in the room.latency-0033
ListenWiFi PL-900 / PL-301 to Android mobile devicesWi-Fi streamingvenue systempath latency252-463statedNo measurement method reported.2017-04-27source datelisten-2017-wifi-latencyFigure 1Manufacturer figures; phone models, sample count, output route and measurement method not given; TV-audio context.Manufacturer (Listen Technologies, maker of the ListenWiFi system described)ManufacturerManufacturer figures; phone models, sample count, output route and measurement method not given; TV-audio context. listen-2017-wifi-latency: The maker's own figures, without a method: the note does not say which phones or how many were tested, the network load, what the delay was measured between, or whether listening was wired or Bluetooth. It describes the 2017 system (PL-900 server and PL-301 access point), so later Listen systems may differ, and it addresses TV viewing rather than live speech in the room.latency-0034
ListenWiFi PL-900 / PL-301 to Apple mobile devicesWi-Fi streamingvenue systempath latency170-214statedNo measurement method reported.2017-04-27source datelisten-2017-wifi-latencyFigure 1Manufacturer figures; phone models, sample count, output route and measurement method not given; TV-audio context.Manufacturer (Listen Technologies, maker of the ListenWiFi system described)ManufacturerManufacturer figures; phone models, sample count, output route and measurement method not given; TV-audio context. listen-2017-wifi-latency: The maker's own figures, without a method: the note does not say which phones or how many were tested, the network load, what the delay was measured between, or whether listening was wired or Bluetooth. It describes the 2017 system (PL-900 server and PL-301 access point), so later Listen systems may differ, and it addresses TV viewing rather than live speech in the room.latency-0035
Source-generated picture to television display (some televisions)Sharedshared-path evidencevideo latency>100statedNo measurement method reported.2017-04-27source datelisten-2017-wifi-latencyTV Input LagManufacturer technical note states some televisions exceed this value, while most are lower; no models or tests specified. Video path only.Manufacturer (Listen Technologies, maker of the ListenWiFi system described)ManufacturerManufacturer technical note states some televisions exceed this value, while most are lower; no models or tests specified. Video path only. listen-2017-wifi-latency: The maker's own figures, without a method: the note does not say which phones or how many were tested, the network load, what the delay was measured between, or whether listening was wired or Bluetooth. It describes the 2017 system (PL-900 server and PL-301 access point), so later Listen systems may differ, and it addresses TV viewing rather than live speech in the room.latency-0036
ListenWIFI server to LWR-1050 receiverWi-Fi streamingvenue systempath latency<40statedNo measurement method reported.2024-02-01source datelisten-2024-lwr1050-receiverArchitectural SpecsManufacturer statement. Good and properly configured network. Conflicts with the other figure on the same page; endpoints not defined.Manufacturer (Listen Technologies, maker of the ListenWIFI system and receiver described, which also sells RF/FM, infrared, hearing loop and Auracast assistive listening products)ManufacturerManufacturer statement. Good and properly configured network. Conflicts with the other figure on the same page; endpoints not defined. listen-2024-lwr1050-receiver: A maker's product page: the latency figures come without a method, a measurement point or network conditions, and its two figures differ (40-60 ms in the table, under 40 ms in the architect's text). The date is the page's publication date in its metadata; it was last modified on 3 September 2026, and the page says specifications are subject to change without notice. The maker's page for its 2-channel server gives the same 40-60 ms and adds that it depends on the listening device.latency-0037
ListenWIFI server to LWR-1050 receiverWi-Fi streamingvenue systempath latency40-60statedNo measurement method reported.2024-02-01source datelisten-2024-lwr1050-receiverSpecifications: Latency (system)Manufacturer statement. Dependent on network, traffic and quality of service. Conflicts with the other figure on the same page; endpoints not defined.Manufacturer (Listen Technologies, maker of the ListenWIFI system and receiver described, which also sells RF/FM, infrared, hearing loop and Auracast assistive listening products)ManufacturerManufacturer statement. Dependent on network, traffic and quality of service. Conflicts with the other figure on the same page; endpoints not defined. listen-2024-lwr1050-receiver: A maker's product page: the latency figures come without a method, a measurement point or network conditions, and its two figures differ (40-60 ms in the table, under 40 ms in the architect's text). The date is the page's publication date in its metadata; it was last modified on 3 September 2026, and the page says specifications are subject to change without notice. The maker's page for its 2-channel server gives the same 40-60 ms and adds that it depends on the listening device.latency-0038
ListenWIFI added delay per inputWi-Fi streamingvenue systemtiming parameter<=3000statedNo measurement method reported.2026-01-15source datelisten-2026-listenwifi-system-manualInput SettingsManufacturer adjustment capacity, not inherent latency. Manual specifies 20 ms increments; converted 3 seconds to 3000 ms.Manufacturer (Listen Technologies, maker of the ListenWIFI system described, which also sells RF/FM, infrared, hearing loop and Auracast assistive listening products)ManufacturerManufacturer adjustment capacity, not inherent latency. Manual specifies 20 ms increments; converted 3 seconds to 3000 ms. listen-2026-listenwifi-system-manual: A maker's manual with no measurements: it gives no latency figure and no way to measure one. The date comes from the file name and the PDF's creation date (15 January 2026, version 5); the PDF's metadata marks it as a draft. The input delay can only make the stream later, so it helps where the stream arrives before the room sound or the picture, not after.latency-0039
Stage to balcony microphone (unaccounted acoustic delay)Sharedvenue systemacoustic travel time~40statedNo measurement method reported.2023-05-13concert date in preprint Procedure, p. 6; delay is a later explanatory estimatemcweeny-2025Verified OSF preprint p. 12 (Discussion)Authors' estimate of uncorrected upstream delay; not intrinsic loop latency. Main concert study: 20 study-aid users and 8 own-aid users. Estimate published in the 22 January 2024 preprint, not a separately dated timing measurement.Independent (McMaster University; AGE-WELL Canada grant); in-kind hearing aids and fittings from Sonova CanadaIndependentAuthors' estimate of uncorrected upstream delay; not intrinsic loop latency. Main concert study: 20 study-aid users and 8 own-aid users. Estimate published in the 22 January 2024 preprint, not a separately dated timing measurement. mcweeny-2025: One concert, one hall and one study hearing-aid model; ratings showed ceiling effects that limited the statistics; orchestral music only. Method and latency details come from the verified 23-page OSF preprint, read alongside the published abstract; the full journal article was not read. The preprint was downloaded and verified against the public OSF file hash on 13 October 2026.latency-0040
Proprietary Wi-Fi device to phone to hearing aidWi-Fi streamingvenue systempath latency~350measuredAuthors report pilot examination; timing method and device models not given.2024-01-22OSF preprint publication date; pilot date not reportedmcweeny-2025Verified OSF preprint p. 13 (Future Directions)Reported pilot result, not the concert participant outcome; most delay attributed to phone-to-hearing-aid hop without a separate number. Pilot sample size is not reported; the 28 concert participants are not a pilot sample count.Independent (McMaster University; AGE-WELL Canada grant); in-kind hearing aids and fittings from Sonova CanadaIndependentReported pilot result, not the concert participant outcome; most delay attributed to phone-to-hearing-aid hop without a separate number. Pilot sample size is not reported; the 28 concert participants are not a pilot sample count. mcweeny-2025: One concert, one hall and one study hearing-aid model; ratings showed ceiling effects that limited the statistics; orchestral music only. Method and latency details come from the verified 23-page OSF preprint, read alongside the published abstract; the full journal article was not read. The preprint was downloaded and verified against the public OSF file hash on 13 October 2026.latency-0041
Opus AuraGate streaming path; receiver unspecifiedAuracastvenue systempath latency<=30statedNo measurement method reported.2025-11source dateopus-2025-auragate-datasheetSpecifications: LatencyManufacturer specification; source date is upload-folder month; no receiver or timing endpoints given.Manufacturer (Opus Technologies)ManufacturerManufacturer specification; source date is upload-folder month; no receiver or timing endpoints given. opus-2025-auragate-datasheet: Undated; the date here is that of its upload folder (November 2025). It does not say which power variant, receiver or method produced the 150 m figure, or between which points latency is measured.latency-0042
Professional installation transmitter to hearing aid: highest resultAuracastvenue systemstudy summary95measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheetpro-audito-2025-compatLatencies - Conclusions!A18; Latencies - values!F7Opus AuraGate to GN ReSound Vivia at 24 kHz. Overlaps matrix row.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentOpus AuraGate to GN ReSound Vivia at 24 kHz. Overlaps matrix row. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0043
Professional installation transmitters: lowest result at 16 kHzAuracastvenue systemstudy summary29measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheetpro-audito-2025-compatLatencies - Conclusions!A9; Latencies - values!K5:K6Conclusions label the receiver as Williams; 29 is in Bettear row K5 while Williams K6 is 30. Preserve value but flag receiver attribution.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentConclusions label the receiver as Williams; 29 is in Bettear row K5 while Williams K6 is 30. Preserve value but flag receiver attribution. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0044
All tested transmitter-receiver pairsAuracastshared-path evidencestudy summary26-205measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheetpro-audito-2025-compatLatencies - Conclusions; matrix B4:AJ14Summary overlaps individual rows; do not count as another test. Includes personal transmitters as well as installation products.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSummary overlaps individual rows; do not count as another test. Includes personal transmitters as well as installation products. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0045
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency74measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA10Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0046
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency73measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA11Sample rate/mode: 24 HR kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0047
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency75measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA12Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0048
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency170measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA14Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0049
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA5Sample rate/mode: 24 HR kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0050
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency45measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA5 commentSample rate/mode: 24 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0051
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency53measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA5 commentSample rate/mode: 24 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0052
Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency102measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA7Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0053
Arendi TV-Streamer FW:0.8.1 to Starkey Edge hearing aidAuracastshared-path evidencepath latency83measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AA8Sample rate/mode: 24 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0054
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency55measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB10Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0055
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency55measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB11Sample rate/mode: 48 LL kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0056
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency57measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB12Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0057
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency127measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB14Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0058
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB3 comment; AB10Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0059
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB3 comment; AB11Sample rate/mode: 48 LL kHz; input: electrical; output: electrical.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0060
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB3 comment; AB12Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0061
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB3 comment; AB14Sample rate/mode: 48 LL kHz; input: electrical; output: acoustic.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0062
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB3 comment; AB5Sample rate/mode: 48 LL kHz; input: electrical; output: electrical.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0063
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency39measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB5Sample rate/mode: 48 LL kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0064
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency39-52measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AB5 commentSample rate/mode: 48 LL kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0065
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency75measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC10Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0066
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency75measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC11Sample rate/mode: 48 HR kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0067
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency77measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC12Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0068
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency147measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC14Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0069
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC3 comment; AC10Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0070
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC3 comment; AC11Sample rate/mode: 48 HR kHz; input: electrical; output: electrical.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0071
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC3 comment; AC12Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0072
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC3 comment; AC14Sample rate/mode: 48 HR kHz; input: electrical; output: acoustic.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0073
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencelatency change-1measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC3 comment; AC5Sample rate/mode: 48 HR kHz; input: electrical; output: electrical.Source reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentSource reports a 1 ms reduction after a few minutes for all receivers; negative means a reduction. No revised absolute value inferred. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0074
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency71measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC5Sample rate/mode: 48 HR kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Column note says every receiver fell by 1 ms after a few minutes; matrix gives the earlier value. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0075
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency42-71measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AC5 commentSample rate/mode: 48 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0076
JBL Tour Pro 3 Case FW:4.6.5 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD10Sample rate/mode: 16 SQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0077
JBL Tour Pro 3 Case FW:4.6.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD11Sample rate/mode: 16 SQ kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0078
JBL Tour Pro 3 Case FW:4.6.5 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency66measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD12Sample rate/mode: 16 SQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0079
JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency52measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD5Sample rate/mode: 16 SQ kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0080
JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency52-85measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD5 commentSample rate/mode: 16 SQ kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0081
JBL Tour Pro 3 Case FW:4.6.5 to Starkey Edge hearing aidAuracastshared-path evidencepath latency85measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD8Sample rate/mode: 16 SQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0082
JBL Tour Pro 3 Case FW:4.6.5 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AD9Sample rate/mode: 16 SQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0083
JBL Tour Pro 3 Case FW:4.6.5 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency77measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE10Sample rate/mode: 48 HQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0084
JBL Tour Pro 3 Case FW:4.6.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency86measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE11Sample rate/mode: 48 HQ kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0085
JBL Tour Pro 3 Case FW:4.6.5 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency78measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE12Sample rate/mode: 48 HQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0086
JBL Tour Pro 3 Case FW:4.6.5 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency120measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE14Sample rate/mode: 48 HQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0087
JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency58measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE5Sample rate/mode: 48 HQ kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0088
JBL Tour Pro 3 Case FW:4.6.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency58-83measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE5 commentSample rate/mode: 48 HQ kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0089
JBL Tour Pro 3 Case FW:4.6.5 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency99measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE7Sample rate/mode: 48 HQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source inconsistency: AE7 gives 99 ms at 48 kHz despite the row note saying 48 kHz is unsupported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source inconsistency: AE7 gives 99 ms at 48 kHz despite the row note saying 48 kHz is unsupported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0090
JBL Tour Pro 3 Case FW:4.6.5 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency86measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AE9Sample rate/mode: 48 HQ kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0091
Moer Moor Duo FW:3.7.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency81measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AF10Sample rate/mode: 48 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0092
Moer Moor Duo FW:3.7.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency90measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AF11Sample rate/mode: 48 kHz; input: acoustic; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0093
Moer Moor Duo FW:3.7.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency85measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AF12Sample rate/mode: 48 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0094
Moer Moor Duo FW:3.7.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency122measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AF14Sample rate/mode: 48 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0095
Moer Moor Duo FW:3.7.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency63measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AF5Sample rate/mode: 48 kHz; input: acoustic; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0096
Moer Moor Duo FW:3.7.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency64measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AF5 commentSample rate/mode: 48 kHz; input: acoustic; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0097
Moor Moer SoundLinker FW:5.2.2 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency34measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0098
Moor Moer SoundLinker FW:5.2.2 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency33measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0099
Moor Moer SoundLinker FW:5.2.2 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency36measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0100
Moor Moer SoundLinker FW:5.2.2 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency80measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0101
Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency26measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0102
Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency26-47measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0103
Moor Moer SoundLinker FW:5.2.2 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0104
Moor Moer SoundLinker FW:5.2.2 to Starkey Edge hearing aidAuracastshared-path evidencepath latency48measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0105
Moor Moer SoundLinker FW:5.2.2 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency34measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AG9Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0106
Moor Moer SoundLinker FW:5.2.2 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH10Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0107
Moor Moer SoundLinker FW:5.2.2 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH11Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0108
Moor Moer SoundLinker FW:5.2.2 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH12Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0109
Moor Moer SoundLinker FW:5.2.2 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency79measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH14Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0110
Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency26measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH5Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0111
Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency27measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH5 commentSample rate/mode: 48 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0112
Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency28measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH5 commentSample rate/mode: 48 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0113
Moor Moer SoundLinker FW:5.2.2 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency46measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AH9Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0114
Moor Moer SoundLinker FW:5.2.2 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency34measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI10Sample rate/mode: 24 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0115
Moor Moer SoundLinker FW:5.2.2 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency34measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI11Sample rate/mode: 24 kHz; input: acoustic; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0116
Moor Moer SoundLinker FW:5.2.2 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency36measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI12Sample rate/mode: 24 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0117
Moor Moer SoundLinker FW:5.2.2 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency81measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI14Sample rate/mode: 24 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0118
Moor Moer SoundLinker FW:5.2.2 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency28measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI5Sample rate/mode: 24 kHz; input: acoustic; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0119
Moor Moer SoundLinker FW:5.2.2 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI7Sample rate/mode: 24 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0120
Moor Moer SoundLinker FW:5.2.2 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency35measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!AI9Sample rate/mode: 24 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0121
Listen Auri TX2N FW:1.5 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency45measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B10Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0122
Listen Auri TX2N FW:1.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency45measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B11Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0123
Listen Auri TX2N FW:1.5 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency47measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B12Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0124
Listen Auri TX2N FW:1.5 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency115measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B14Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0125
Listen Auri TX2N FW:1.5 to Listen Auri RX1 FW:1.5Auracastvenue systempath latency36measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B4Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Cell comment says this Auri-to-Auri reading is higher than previous tests and other reports; further testing is required.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Cell comment says this Auri-to-Auri reading is higher than previous tests and other reports; further testing is required. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0126
Listen Auri TX2N FW:1.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B5Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0127
Listen Auri TX2N FW:1.5 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency54measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B7Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0128
Listen Auri TX2N FW:1.5 to JBL Tour Pro 3 FW:4.9.5Auracastvenue systempath latency46measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!B9Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0129
Listen Auri TX2N FW:1.5 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency48measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0130
Listen Auri TX2N FW:1.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency47measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0131
Listen Auri TX2N FW:1.5 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0132
Listen Auri TX2N FW:1.5 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency113measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0133
Listen Auri TX2N FW:1.5 to Listen Auri RX1 FW:1.5Auracastvenue systempath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C4Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Cell comment says this Auri-to-Auri reading is higher than previous tests and other reports; further testing is required.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Cell comment says this Auri-to-Auri reading is higher than previous tests and other reports; further testing is required. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0134
Listen Auri TX2N FW:1.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency47measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0135
Listen Auri TX2N FW:1.5 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency55measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0136
Listen Auri TX2N FW:1.5 to JBL Tour Pro 3 FW:4.9.5Auracastvenue systempath latency48measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!C9Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0137
Listen Auri TX2N FW:1.5 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency50measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!D10Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0138
Listen Auri TX2N FW:1.5 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency59measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!D11Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0139
Listen Auri TX2N FW:1.5 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency111measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!D14Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0140
Listen Auri TX2N FW:1.5 to Listen Auri RX1 FW:1.5Auracastvenue systempath latency55measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!D4Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Cell comment says this Auri-to-Auri reading is higher than previous tests and other reports; further testing is required.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Cell comment says this Auri-to-Auri reading is higher than previous tests and other reports; further testing is required. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0141
Listen Auri TX2N FW:1.5 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!D5Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0142
Listen Auri TX2N FW:1.5 to JBL Tour Pro 3 FW:4.9.5Auracastvenue systempath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!D9Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0143
Opus Auragate FW:2.1.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency66measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E10Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0144
Opus Auragate FW:2.1.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency65measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E11Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0145
Opus Auragate FW:2.1.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E12Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0146
Opus Auragate FW:2.1.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency145measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E14Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0147
Opus Auragate FW:2.1.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency58measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E5Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0148
Opus Auragate FW:2.1.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency94measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E7Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0149
Opus Auragate FW:2.1.0 to Starkey Edge hearing aidAuracastvenue systempath latency80measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!E8Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0150
Opus Auragate FW:2.1.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0151
Opus Auragate FW:2.1.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency66measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0152
Opus Auragate FW:2.1.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0153
Opus Auragate FW:2.1.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency143measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0154
Opus Auragate FW:2.1.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0155
Opus Auragate FW:2.1.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency95measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0156
Opus Auragate FW:2.1.0 to Starkey Edge hearing aidAuracastvenue systempath latency80measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!F8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0157
Opus Auragate FW:2.1.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!G10Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0158
Opus Auragate FW:2.1.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!G11Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0159
Opus Auragate FW:2.1.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency69measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!G12Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0160
Opus Auragate FW:2.1.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency139measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!G14Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0161
Opus Auragate FW:2.1.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!G5Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0162
Opus Auragate FW:2.1.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency66measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!G5 commentSample rate/mode: 48 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0163
Bettear B-CASTER FW:1.0.3 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency39measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H10Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0164
Bettear B-CASTER FW:1.0.3 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency39measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H11Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0165
Bettear B-CASTER FW:1.0.3 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency41measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H12Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0166
Bettear B-CASTER FW:1.0.3 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency88measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H14Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0167
Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency33measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H5Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Transmitter note reports approximately 1 ms fluctuation. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Transmitter note reports approximately 1 ms fluctuation. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0168
Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency41measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H5 commentSample rate/mode: 16 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0169
Bettear B-CASTER FW:1.0.3 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H7Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0170
Bettear B-CASTER FW:1.0.3 to Starkey Edge hearing aidAuracastvenue systempath latency52measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!H8Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0171
Bettear B-CASTER FW:1.0.3 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency41measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0172
Bettear B-CASTER FW:1.0.3 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0173
Bettear B-CASTER FW:1.0.3 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency43measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0174
Bettear B-CASTER FW:1.0.3 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency87measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0175
Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency34measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Transmitter note reports approximately 1 ms fluctuation. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Transmitter note reports approximately 1 ms fluctuation. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0176
Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency41measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0177
Bettear B-CASTER FW:1.0.3 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0178
Bettear B-CASTER FW:1.0.3 to Starkey Edge hearing aidAuracastvenue systempath latency53measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!I8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0179
Bettear B-CASTER FW:1.0.3 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!J10Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0180
Bettear B-CASTER FW:1.0.3 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency43measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!J11Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0181
Bettear B-CASTER FW:1.0.3 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency46measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!J12Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0182
Bettear B-CASTER FW:1.0.3 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency85measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!J14Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Transmitter note reports approximately 1 ms fluctuation. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0183
Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency36measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!J5Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Transmitter note reports approximately 1 ms fluctuation. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Transmitter note reports approximately 1 ms fluctuation. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0184
Bettear B-CASTER FW:1.0.3 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency43measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!J5 commentSample rate/mode: 48 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0185
William Infinium FW:1.4.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency35measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K10Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0186
William Infinium FW:1.4.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency35measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K11Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0187
William Infinium FW:1.4.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K12Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0188
William Infinium FW:1.4.0 to Moor Moer hearClearAuracastvenue systempath latency35measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K13Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0189
William Infinium FW:1.4.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency85measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K14Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0190
William Infinium FW:1.4.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency29measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K5Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0191
William Infinium FW:1.4.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K5 commentSample rate/mode: 16 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0192
William Infinium FW:1.4.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K5 commentSample rate/mode: 16 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0193
William Infinium FW:1.4.0 to Williams Infinium Rx FW:?Auracastvenue systempath latency30measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K6Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0194
William Infinium FW:1.4.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency64measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K7Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0195
William Infinium FW:1.4.0 to Starkey Edge hearing aidAuracastvenue systempath latency50measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!K8Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0196
William Infinium FW:1.4.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0197
William Infinium FW:1.4.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0198
William Infinium FW:1.4.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency43measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0199
William Infinium FW:1.4.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency85measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0200
William Infinium FW:1.4.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency33measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0201
William Infinium FW:1.4.0 to Williams Infinium Rx FW:?Auracastvenue systempath latency32measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L6Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0202
William Infinium FW:1.4.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency65measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0203
William Infinium FW:1.4.0 to Starkey Edge hearing aidAuracastvenue systempath latency53measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!L8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0204
Bettear RTX FW:1.0.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency41measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0205
Bettear RTX FW:1.0.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0206
Bettear RTX FW:1.0.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency45measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0207
Bettear RTX FW:1.0.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency87measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0208
Bettear RTX FW:1.0.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency34measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0209
Bettear RTX FW:1.0.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0210
Bettear RTX FW:1.0.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!M7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0211
Opus AurOEM & AurLoop FW:2.0.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency96measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N10Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0212
Opus AurOEM & AurLoop FW:2.0.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency95measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N11Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0213
Opus AurOEM & AurLoop FW:2.0.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency97measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N12Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0214
Opus AurOEM & AurLoop FW:2.0.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency205measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N14Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0215
AurOEM/AuraLoop at 16 kHz: firmware 2.0.0 relative to 1.2.0Auracastvenue systemlatency change30measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheetpro-audito-2025-compatLatencies - values!N3 commentIncrease; source attribution between AurOEM and AuraLoop is inconsistent.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentIncrease; source attribution between AurOEM and AuraLoop is inconsistent. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0216
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency88measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N5Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0217
Opus AurOEM & AurLoop FW:2.0.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency124measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N7Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0218
Opus AurOEM & AurLoop FW:2.0.0 to Starkey Edge hearing aidAuracastvenue systempath latency110measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!N8Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. N3 reports firmware 2.0.0 adds 30 ms relative to 1.2.0. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0219
Opus AurOEM & AurLoop FW:2.0.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency66measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0220
Opus AurOEM & AurLoop FW:2.0.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency65measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0221
Opus AurOEM & AurLoop FW:2.0.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0222
Opus AurOEM & AurLoop FW:2.0.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency142measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0223
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Source inconsistency: O5 is 49 ms but its comment starts at 39 ms. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Source inconsistency: O5 is 49 ms but its comment starts at 39 ms. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0224
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment starts at 39 ms although matrix O5 is 49 ms; unresolved. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment starts at 39 ms although matrix O5 is 49 ms; unresolved. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0225
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency39measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment starts at 39 ms although matrix O5 is 49 ms; unresolved. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment starts at 39 ms although matrix O5 is 49 ms; unresolved. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0226
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency58measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment starts at 39 ms although matrix O5 is 49 ms; unresolved. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment starts at 39 ms although matrix O5 is 49 ms; unresolved. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0227
Opus AurOEM & AurLoop FW:2.0.0 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastvenue systempath latency94measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0228
Opus AurOEM & AurLoop FW:2.0.0 to Starkey Edge hearing aidAuracastvenue systempath latency80measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!O8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0229
Opus AurOEM & AurLoop FW:2.0.0 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastvenue systempath latency68measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P10Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0230
Opus AurOEM & AurLoop FW:2.0.0 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastvenue systempath latency67measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P11Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0231
Opus AurOEM & AurLoop FW:2.0.0 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastvenue systempath latency69measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P12Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0232
Opus AurOEM & AurLoop FW:2.0.0 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastvenue systempath latency139measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P14Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0233
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency39measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P5Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Combined AurOEM/AurLoop header: N3 says the 16 kHz measurement used AuraLoop; N1 says measurements used AurOEM and AurLoop supports only 16/24 kHz. Hardware attribution is unresolved. Additional values from this cell comment have separate rows. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0234
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P5 commentSample rate/mode: 48 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0235
Opus AurOEM & AurLoop FW:2.0.0 to Bettear RTX FW:1.0.1 & 1.0.3Auracastvenue systempath latency58measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!P5 commentSample rate/mode: 48 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. Header groups AurOEM and AurLoop; N1 says measurements used AurOEM and AurLoop only supports 16/24 kHz, while N3 names AuraLoop for the 16 kHz test. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0236
GN TV-Streamer + FW:1.0.2.7 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency47measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0237
GN TV-Streamer + FW:1.0.2.7 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency46measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0238
GN TV-Streamer + FW:1.0.2.7 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0239
GN TV-Streamer + FW:1.0.2.7 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency103measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0240
GN TV-Streamer + FW:1.0.2.7 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0241
GN TV-Streamer + FW:1.0.2.7 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency54measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0242
GN TV-Streamer + FW:1.0.2.7 to Starkey Edge hearing aidAuracastshared-path evidencepath latency60measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0243
GN TV-Streamer + FW:1.0.2.7 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency48measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Q9Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0244
GN MultiMic+ FW:1.0.2.7 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R10Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0245
GN MultiMic+ FW:1.0.2.7 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency36measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R11Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0246
GN MultiMic+ FW:1.0.2.7 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R12Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0247
GN MultiMic+ FW:1.0.2.7 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency87measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R14Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0248
GN MultiMic+ FW:1.0.2.7 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency29measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R5Sample rate/mode: 16 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0249
GN MultiMic+ FW:1.0.2.7 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R7Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0250
GN MultiMic+ FW:1.0.2.7 to Starkey Edge hearing aidAuracastshared-path evidencepath latency50measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R8Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0251
GN MultiMic+ FW:1.0.2.7 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!R9Sample rate/mode: 16 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0252
GN MultiMic+ FW:1.0.2.7 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!S10Sample rate/mode: 16 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0253
GN MultiMic+ FW:1.0.2.7 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!S11Sample rate/mode: 16 kHz; input: acoustic; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0254
GN MultiMic+ FW:1.0.2.7 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!S12Sample rate/mode: 16 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0255
GN MultiMic+ FW:1.0.2.7 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency39measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!S9Sample rate/mode: 16 kHz; input: acoustic; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0256
GN MultiMic+ FW:1.0.2.7 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!T11Sample rate/mode: 16 kHz; input: magnetic telecoil; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0257
Starkey TV-Streamer to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency43measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!U10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0258
Starkey TV-Streamer to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!U11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0259
Starkey TV-Streamer to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!U12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0260
Starkey TV-Streamer to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency49measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!U7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0261
Starkey TV-Streamer to Starkey Edge hearing aidAuracastshared-path evidencepath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!U8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0262
Starkey TV-Streamer to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency43measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!U9Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0263
Humantechnik EarisMAX Transmitter FW:3.6.6 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency37measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V10Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0264
Humantechnik EarisMAX Transmitter FW:3.6.6 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V11Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0265
Humantechnik EarisMAX Transmitter FW:3.6.6 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V12Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0266
Humantechnik EarisMAX Transmitter FW:3.6.6 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency89measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V14Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0267
Humantechnik EarisMAX Transmitter FW:3.6.6 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency36measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V5Sample rate/mode: 24 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0268
Humantechnik EarisMAX Transmitter FW:3.6.6 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency44measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V5 commentSample rate/mode: 24 kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0269
Humantechnik EarisMAX Transmitter FW:3.6.6 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency70measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V7Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0270
Humantechnik EarisMAX Transmitter FW:3.6.6 to Starkey Edge hearing aidAuracastshared-path evidencepath latency56measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!V8Sample rate/mode: 24 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0271
Humantechnik EarisMAX Transmitter FW:3.6.6 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency57measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!W10Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0272
Humantechnik EarisMAX Transmitter FW:3.6.6 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency57measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!W11Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0273
Humantechnik EarisMAX Transmitter FW:3.6.6 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency59measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!W12Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0274
Humantechnik EarisMAX Transmitter FW:3.6.6 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency99measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!W14Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0275
Humantechnik EarisMAX Transmitter FW:3.6.6 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency48measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!W5Sample rate/mode: 48 kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0276
Humantechnik EarisMAX Transmitter FW:3.6.6 to JBL Tour Pro 3 FW:4.9.5Auracastshared-path evidencepath latency66measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!W9Sample rate/mode: 48 kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0277
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X10Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0278
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency38measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X11Sample rate/mode: 16 LL kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0279
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X12Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0280
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency110measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X14Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0281
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency32measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X5Sample rate/mode: 16 LL kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Cell comment specifically attributes stream availability to Bettear RTX receiver firmware 1.0.3. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0282
Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency69measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X7Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0283
Arendi TV-Streamer FW:0.8.1 to Starkey Edge hearing aidAuracastshared-path evidencepath latency53measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!X8Sample rate/mode: 16 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0284
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency70measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y10Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0285
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency73measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y10 commentSample rate/mode: 16 HR kHz; input: electrical; output: acoustic.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0286
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency69measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y11Sample rate/mode: 16 HR kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0287
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency72measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y11 commentSample rate/mode: 16 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0288
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency74measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y12Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0289
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency172measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y14Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0290
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y5Sample rate/mode: 16 HR kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0291
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency45measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y5 commentSample rate/mode: 16 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0292
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency54measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y5 commentSample rate/mode: 16 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0293
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency60measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y5 commentSample rate/mode: 16 HR kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0294
Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency101measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y7Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0295
Arendi TV-Streamer FW:0.8.1 to Starkey Edge hearing aidAuracastshared-path evidencepath latency83measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Y8Sample rate/mode: 16 HR kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0296
Arendi TV-Streamer FW:0.8.1 to Humantechnik earis MAX Headphone FW: 4.4.0Auracastshared-path evidencepath latency41measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z10Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0297
Arendi TV-Streamer FW:0.8.1 to Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5Auracastshared-path evidencepath latency40measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z11Sample rate/mode: 24 LL kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0298
Arendi TV-Streamer FW:0.8.1 to Moer The Show FW:? *2 via BT Menu on Samsung Galaxy S23 UltraAuracastshared-path evidencepath latency42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z12Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Source row note: 48 kHz requires automatic connection; phone Bluetooth-menu connection did not work. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0299
Arendi TV-Streamer FW:0.8.1 to Samsung Buds Pro 3 FW:R630XXU0AYG3Auracastshared-path evidencepath latency108measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z14Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0300
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency31measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z5Sample rate/mode: 24 LL kHz; input: electrical; output: electrical.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. Receiver delay can rise after connection; matrix may mix initial and elevated readings; receiver firmware 1.0.1/1.0.3 is not resolved for every cell. Additional values from this cell comment have separate rows. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0301
Arendi TV-Streamer FW:0.8.1 to Bettear RTX FW:1.0.1 & 1.0.3Auracastshared-path evidencepath latency31-42measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z5 commentSample rate/mode: 24 LL kHz; input: electrical; output: electrical.Later or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentLater or fluctuating latency reported in the cell comment; same test path. Comment timestamps are edit dates, not assumed measurement dates. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0302
Arendi TV-Streamer FW:0.8.1 to GN Resound Vivia FW:10.21.2.1 via App iPhone 12Auracastshared-path evidencepath latency70measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z7Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0303
Arendi TV-Streamer FW:0.8.1 to Starkey Edge hearing aidAuracastshared-path evidencepath latency52measuredPseudo-random full-range pink noise; transfer function using Smaart V8 and QSC Q-SYS Core 8 flex (Designer V9.13); one transmitter at a time.2025-08-25/2025-09-05measurement interval stated on setup sheet; later comments not separately dated as testspro-audito-2025-compatLatencies - values!Z8Sample rate/mode: 24 LL kHz; input: electrical; output: acoustic.Matrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported.Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)IndependentMatrix value; firmware and assistant details are included in the path. Assistants select the stream and are not an extra audio hop. No participant count reported. pro-audito-2025-compat: Results apply only to the firmware versions tested, and some firmware changed during the three weeks of testing. The hall test used one deliberately distant transmitter position and no significant interference from event equipment; the testers say it is not representative of other rooms.latency-0304
Auracast transmitter to receiverAuracastvenue systempath latency~30-40+statedNo measurement method reported.2025-02-17source datepro-audito-2025-operator-guidanceLatenz von Auracast-SystemenPractical guidance; some pairs take longer.Nonprofit advocacy (Pro Audito Schweiz, Swiss hearing-loss association)Nonprofit advocacyPractical guidance; some pairs take longer. pro-audito-2025-operator-guidance: Guidance from early practical experience, not a controlled study. The range figure is an estimate. The page bears a 17 February 2025 date but the archived text discusses the new SIA 500 draft; no revision date is stated, so the displayed date does not establish when every passage was written.latency-0305
Venue audio system before AuracastSharedvenue systemcomponent latencyup to 20 or morestatedNo measurement method reported.2025-02-17source datepro-audito-2025-operator-guidanceLatenz von Auracast-SystemenDepends on wireless microphones and signal distribution; 20 is not an upper bound.Nonprofit advocacy (Pro Audito Schweiz, Swiss hearing-loss association)Nonprofit advocacyDepends on wireless microphones and signal distribution; 20 is not an upper bound. pro-audito-2025-operator-guidance: Guidance from early practical experience, not a controlled study. The range figure is an estimate. The page bears a 17 February 2025 date but the archived text discusses the new SIA 500 draft; no revision date is stated, so the displayed date does not establish when every passage was written.latency-0306
Auri RX1 output relative to loudspeaker sound at rear seatAuracastvenue systemrelative arrival offset<30measuredSimultaneous video/audio recording of airborne sound and RX1 output; offset evaluated in Audacity.2025-11-03source datepro-audito-2025-pilatus-arenaTest: simultaneous recording paragraphStream leads loudspeaker sound; magnitude only. One rear seat during a match; not transmitter-to-ear latency; no participant count given.Independent (Pro Audito Schweiz, Swiss hearing-loss association; test devices were lent free by their manufacturers or owned by participants)IndependentStream leads loudspeaker sound; magnitude only. One rear seat during a match; not transmitter-to-ear latency; no participant count given. pro-audito-2025-pilatus-arena: One visit during a match, with one transmitter brand. The test section describes a short recording, without stating the duration of the visit, participant count, attendance, full-bowl coverage or seat-to-transmitter distances. Ratings are the testers' judgement without stated criteria. The delay was measured at one rear seat through a dedicated receiver, not through each hearing aid.latency-0307
Audio system plus airborne path to distant directional microphoneSharedvenue systemcomponent latency~30statedNo measurement method reported.2025-03-17source datepro-audito-2025-theatre-aarauLatenz – die Zeit, bis das Audio in den Ohren ankommtAlte Reithalle, Bühne Aarau; empty room, one transmitter system and one hearing-aid model. Total is the authors' estimate from adding upstream delay.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentAlte Reithalle, Bühne Aarau; empty room, one transmitter system and one hearing-aid model. Total is the authors' estimate from adding upstream delay. pro-audito-2025-theatre-aarau: One room, one transmitter system and one hearing aid model (GN ReSound Nexia, named in the latency section); listener and audience counts unstated, with crowded operation untested. No comparison of fitting types or separate financial support is reported. Latency depends on the configuration and firmware at the time.latency-0308
Talker through audio system and Auracast to listenerAuracastvenue systempath latency~65-90statedNo measurement method reported.2025-03-17source datepro-audito-2025-theatre-aarauLatenz – die Zeit, bis das Audio in den Ohren ankommtAlte Reithalle, Bühne Aarau; empty room, one transmitter system and one hearing-aid model. Total is the authors' estimate from adding upstream delay.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentAlte Reithalle, Bühne Aarau; empty room, one transmitter system and one hearing-aid model. Total is the authors' estimate from adding upstream delay. pro-audito-2025-theatre-aarau: One room, one transmitter system and one hearing aid model (GN ReSound Nexia, named in the latency section); listener and audience counts unstated, with crowded operation untested. No comparison of fitting types or separate financial support is reported. Latency depends on the configuration and firmware at the time.latency-0309
Transmitter to GN ReSound Nexia hearing aidsAuracastvenue systempath latency56-58measuredNo measurement method reported.2025-03-17source datepro-audito-2025-theatre-aarauLatenz – die Zeit, bis das Audio in den Ohren ankommtAlte Reithalle, Bühne Aarau; one transmitter system and one hearing-aid model; listener and audience counts not reported. The 56-58 ms value covers transmitter to hearing aid; the separate estimated total of roughly 65-90 ms includes upstream delay and spans receiver and hearing-aid paths.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentAlte Reithalle, Bühne Aarau; one transmitter system and one hearing-aid model; listener and audience counts not reported. The 56-58 ms value covers transmitter to hearing aid; the separate estimated total of roughly 65-90 ms includes upstream delay and spans receiver and hearing-aid paths. pro-audito-2025-theatre-aarau: One room, one transmitter system and one hearing aid model (GN ReSound Nexia, named in the latency section); listener and audience counts unstated, with crowded operation untested. No comparison of fitting types or separate financial support is reported. Latency depends on the configuration and firmware at the time.latency-0310
Transmitter to neckloop receiversAuracastvenue systempath latency36-43measuredNo measurement method reported.2025-03-17source datepro-audito-2025-theatre-aarauLatenz – die Zeit, bis das Audio in den Ohren ankommtAlte Reithalle, Bühne Aarau; empty room, one transmitter system and one hearing-aid model. Total is the authors' estimate from adding upstream delay.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentAlte Reithalle, Bühne Aarau; empty room, one transmitter system and one hearing-aid model. Total is the authors' estimate from adding upstream delay. pro-audito-2025-theatre-aarau: One room, one transmitter system and one hearing aid model (GN ReSound Nexia, named in the latency section); listener and audience counts unstated, with crowded operation untested. No comparison of fitting types or separate financial support is reported. Latency depends on the configuration and firmware at the time.latency-0311
Accessify over 5G relative to airborne soundSharedvenue systemrelative arrival offset260-335statedDifferences reported in the table, derived from system latency and the 25-100 ms front/back airborne-sound reference.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Stream lags.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Stream lags. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0312
Accessify over 5G streamingSharedvenue systempath latency~360measuredOutdoor comparison; timing instrument and endpoint procedure not reported.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Mobile internet path; not venue Wi-Fi.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Mobile internet path; not venue Wi-Fi. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0313
Auracast hearing aid relative to airborne soundAuracastvenue systemrelative arrival offset29-46statedDifferences reported in the table, derived from system latency and the 25-100 ms front/back airborne-sound reference.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Printed front/back differences; not extrema over every position. Stream lags at the front endpoint and leads at the back; it can coincide with room sound between them.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Printed front/back differences; not extrema over every position. Stream lags at the front endpoint and leads at the back; it can coincide with room sound between them. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0314
Auracast receiver relative to airborne soundAuracastvenue systemrelative arrival offset18-57statedDifferences reported in the table, derived from system latency and the 25-100 ms front/back airborne-sound reference.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Printed front/back differences; not extrema over every position. Stream lags at the front endpoint and leads at the back; it can coincide with room sound between them.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Printed front/back differences; not extrema over every position. Stream lags at the front endpoint and leads at the back; it can coincide with room sound between them. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0315
Auracast transmitter to hearing aidAuracastvenue systempath latency54measuredOutdoor comparison; timing instrument and endpoint procedure not reported.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0316
Auracast transmitter to receiverAuracastvenue systempath latency43measuredOutdoor comparison; timing instrument and endpoint procedure not reported.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0317
FM relative to airborne soundRF/FMvenue systemrelative arrival offset17-92statedDifferences reported in the table, derived from system latency and the 25-100 ms front/back airborne-sound reference.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Unsigned differences as printed; stream leads.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Unsigned differences as printed; stream leads. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0318
FM systemRF/FMvenue systempath latency8measuredOutdoor comparison; timing instrument and endpoint procedure not reported.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0319
Loudspeakers through air to listenersSharedvenue systemacoustic travel time25-100measuredOutdoor comparison; timing instrument and endpoint procedure not reported.2026-05-02event date; separate timing-test date not givenpro-audito-2026-outdoorLatency in comparison tableHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Front/back positions.Independent (Pro Audito Schweiz, Swiss hearing-loss association)IndependentHelvetiaplatz, Zurich; event of about 2000 people; tester/device counts not specified. Front/back positions. pro-audito-2026-outdoor: One event, one transmitter position and the authors' own receivers; machine-translated from German.latency-0320
Avantree Oasis Aura to AuraClipAuracastvenue systempath latency65measuredNo measurement method reported.2026-07-16source datepro-audito-2026-venucast-testOpening test resultsShort test with lent units; no firmware, test date, hearing-aid models or device count given.Independent (Pro Audito Schweiz, Swiss hearing-loss association; test units lent free by the manufacturer, Pro Audito not paid)IndependentShort test with lent units; no firmware, test date, hearing-aid models or device count given. pro-audito-2026-venucast-test: Short test of one system supplied free by the manufacturer; the page does not specify whether the devices were loaned or given. Firmware, test room, distances and hearing-aid models are not stated. In German.latency-0321
Avantree Oasis Aura to fastest tested receiver; model unspecifiedAuracastvenue systempath latency57measuredNo measurement method reported.2026-07-16source datepro-audito-2026-venucast-testOpening test resultsShort test with lent units; no firmware, test date, hearing-aid models or device count given.Independent (Pro Audito Schweiz, Swiss hearing-loss association; test units lent free by the manufacturer, Pro Audito not paid)IndependentShort test with lent units; no firmware, test date, hearing-aid models or device count given. pro-audito-2026-venucast-test: Short test of one system supplied free by the manufacturer; the page does not specify whether the devices were loaned or given. Firmware, test room, distances and hearing-aid models are not stated. In German.latency-0322
Avantree Oasis Aura to hearing aidsAuracastvenue systempath latency65-75measuredNo measurement method reported.2026-07-16source datepro-audito-2026-venucast-testOpening test resultsShort test with lent units; no firmware, test date, hearing-aid models or device count given.Independent (Pro Audito Schweiz, Swiss hearing-loss association; test units lent free by the manufacturer, Pro Audito not paid)IndependentShort test with lent units; no firmware, test date, hearing-aid models or device count given. pro-audito-2026-venucast-test: Short test of one system supplied free by the manufacturer; the page does not specify whether the devices were loaned or given. Firmware, test room, distances and hearing-aid models are not stated. In German.latency-0323
MobileConnect stream to phone appWi-Fi streamingvenue systempath latency40-60statedNo measurement method reported.2023source datesennheiser-2023-mobileconnect-specMobileConnect App: Low latencyManufacturer average; devices, network load and output route unspecified. Source year is PDF creation year.Manufacturer (Sennheiser, maker of the MobileConnect Wi-Fi system)ManufacturerManufacturer average; devices, network load and output route unspecified. Source year is PDF creation year. sennheiser-2023-mobileconnect-spec: A maker's data sheet: the latency is an average with no stated method, phones, network load or listening path (wired, neckloop or Bluetooth), and the capacity is given per station without network conditions. No date is printed; the year comes from the PDF's creation date (16 January 2023). Sennheiser's MobileConnect product page linked this version on 9 October 2026.latency-0324
MobileConnect Audience Mic return pathWi-Fi streamingshared-path evidencepath latencyas low as 25statedNo measurement method reported.undatedundated sourcesennheiser-mobileconnect-app-pageFeature list: Audience MicManufacturer statement. Talk-back path, not audience receiving path.Manufacturer (Sennheiser, maker of the MobileConnect Wi-Fi system)ManufacturerManufacturer statement. Talk-back path, not audience receiving path. sennheiser-mobileconnect-app-page: A maker's marketing page with no method, phones, network load or listening path behind either figure; the 25 ms in the text may refer to the talk-back microphone, as the feature list states. The page carries no date. Sennheiser's data sheet gives 40-60 ms on average for the app.latency-0325
MobileConnect unicast streamWi-Fi streamingvenue systempath latency40-60statedNo measurement method reported.undatedundated sourcesennheiser-mobileconnect-app-pageFeature list: Unicast audio streamingManufacturer statement. Dependent on network and user devices.Manufacturer (Sennheiser, maker of the MobileConnect Wi-Fi system)ManufacturerManufacturer statement. Dependent on network and user devices. sennheiser-mobileconnect-app-page: A maker's marketing page with no method, phones, network load or listening path behind either figure; the 25 ms in the text may refer to the talk-back microphone, as the feature list states. The page carries no date. Sennheiser's data sheet gives 40-60 ms on average for the app.latency-0326
MobileConnect unicast hearing-assistance streamWi-Fi streamingvenue systempath latencyas low as 25statedNo measurement method reported.undatedundated sourcesennheiser-mobileconnect-app-pageProduct descriptionManufacturer statement. Potentially confused with Audience Mic value on same page.Manufacturer (Sennheiser, maker of the MobileConnect Wi-Fi system)ManufacturerManufacturer statement. Potentially confused with Audience Mic value on same page. sennheiser-mobileconnect-app-page: A maker's marketing page with no method, phones, network load or listening path behind either figure; the 25 ms in the text may refer to the talk-back microphone, as the feature list states. The page carries no date. Sennheiser's data sheet gives 40-60 ms on average for the app.latency-0327
All Auracast receivers: Presentation Delay supportAuracastvenue systemtiming parameter40statedNo measurement method reported.2025-02-06source datesig-2025-earbuds-guidePresentation Delay sectionDesign guidance about supported timing values, not end-to-end latency.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodyDesign guidance about supported timing values, not end-to-end latency. sig-2025-earbuds-guide: Design recommendations, not test results; how far shipping products follow them is not reported.latency-0328
HAP/TMAP receivers: Presentation Delay supportAuracastvenue systemtiming parameter20-40statedNo measurement method reported.2025-02-06source datesig-2025-earbuds-guidePresentation Delay sectionDesign guidance about supported timing values, not end-to-end latency.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodyDesign guidance about supported timing values, not end-to-end latency. sig-2025-earbuds-guide: Design recommendations, not test results; how far shipping products follow them is not reported.latency-0329
Simple transmitter example: Presentation DelayAuracastvenue systemtiming parameter40statedNo measurement method reported.2025-10-17source datesig-transmitter-guide-v3Example BASE settingsExample parameter; immediate rendering can allow earlier playback.Standards body (Bluetooth SIG, an industry association funded by its member companies, which owns the Auracast trademark)Standards bodyExample parameter; immediate rendering can allow earlier playback. sig-transmitter-guide-v3: Mostly recommendations; its mandatory statements come from the Auracast trademark requirements. It sets no numeric coverage or signal-strength pass/fail level.latency-0330
Auracast transmissionAuracastvenue systempath latency30-40+statedNo measurement method reported.2025-01source datesterkens-whyman-2025Latency paragraphAdvocacy estimate; additional to other system delays. The phone assistant is discussed separately, not measured as an audio hop.Nonprofit advocacy (both authors work with the Center for Hearing Access: Wynne Whyman as its director of communication and advocacy, Juliëtte Sterkens as its hearing access advocate; Sterkens left practice in 2012 to work as HLAA's national hearing loop advocate, with outreach funded by the David & Carol Myers Foundation)Nonprofit advocacyAdvocacy estimate; additional to other system delays. The phone assistant is discussed separately, not measured as an audio hop. sterkens-whyman-2025: An opinion piece by loop advocates, with no new data; the 99.9% figure is the authors' estimate. Written in January 2025 (the page's metadata gives 15 January 2025), before most Auracast hearing devices and transmitters were available. The statement that IEC 60118-4 requires automatic gain control has not been checked here against the paywalled standard. The authors' affiliations are from the Center for Hearing Access leadership page and a 2019 Hearing Review interview, not the article itself.latency-0331
Tsinghua campus Wi-Fi hop (90th percentile of one-minute average round-trip time)Wi-Fi streamingshared-path evidencenetwork round-trip time~20measuredping2: first ping wakes device; second ping RTT used. Six measurements ten seconds apart averaged per minute; wired path treated as negligible.2016-06source datesui-2016Sections 2.1 and 3.1More than 47000 devices; general data network, no audio playback. Do not interpret as one-way audio latency or add directly to audio-path figures. Percentiles describe the one-minute records, not individual packets.Independent (Tsinghua University, with one author from Microsoft Research; supported by National Natural Science Foundation of China and other Chinese government research grants)IndependentMore than 47000 devices; general data network, no audio playback. Do not interpret as one-way audio latency or add directly to audio-path figures. Percentiles describe the one-minute records, not individual packets. sui-2016: A general study of one campus data network, not of audio streaming or assistive listening: it estimates the wireless-hop round-trip delay using a second ping after a wake-up ping, not the audio buffering, codecs or phone playback that add to a stream's delay, and reports no audio results. Wi-Fi equipment has changed since 2016. Read in the authors' copy hosted by Microsoft Research; the ACM page is the published version.latency-0332
Tsinghua campus Wi-Fi hop (99th percentile of one-minute average round-trip time)Wi-Fi streamingshared-path evidencenetwork round-trip time~250measuredping2: first ping wakes device; second ping RTT used. Six measurements ten seconds apart averaged per minute; wired path treated as negligible.2016-06source datesui-2016Sections 2.1 and 3.1More than 47000 devices; general data network, no audio playback. Do not interpret as one-way audio latency or add directly to audio-path figures. Percentiles describe the one-minute records, not individual packets.Independent (Tsinghua University, with one author from Microsoft Research; supported by National Natural Science Foundation of China and other Chinese government research grants)IndependentMore than 47000 devices; general data network, no audio playback. Do not interpret as one-way audio latency or add directly to audio-path figures. Percentiles describe the one-minute records, not individual packets. sui-2016: A general study of one campus data network, not of audio streaming or assistive listening: it estimates the wireless-hop round-trip delay using a second ping after a wake-up ping, not the audio buffering, codecs or phone playback that add to a stream's delay, and reports no audio results. Wi-Fi equipment has changed since 2016. Read in the authors' copy hosted by Microsoft Research; the ACM page is the published version.latency-0333
Tsinghua campus Wi-Fi hop (median of one-minute average round-trip time)Wi-Fi streamingshared-path evidencenetwork round-trip time~3measuredping2: first ping wakes device; second ping RTT used. Six measurements ten seconds apart averaged per minute; wired path treated as negligible.2016-06source datesui-2016Sections 2.1 and 3.1More than 47000 devices; general data network, no audio playback. Do not interpret as one-way audio latency or add directly to audio-path figures. Percentiles describe the one-minute records, not individual packets.Independent (Tsinghua University, with one author from Microsoft Research; supported by National Natural Science Foundation of China and other Chinese government research grants)IndependentMore than 47000 devices; general data network, no audio playback. Do not interpret as one-way audio latency or add directly to audio-path figures. Percentiles describe the one-minute records, not individual packets. sui-2016: A general study of one campus data network, not of audio streaming or assistive listening: it estimates the wireless-hop round-trip delay using a second ping after a wake-up ping, not the audio buffering, codecs or phone playback that add to a stream's delay, and reports no audio results. Wi-Fi equipment has changed since 2016. Read in the authors' copy hosted by Microsoft Research; the ACM page is the published version.latency-0334
Wi-Fi listening system to standard smartphonesWi-Fi streamingvenue systempath latency>130measuredNo measurement method reported.2025-04-29source datetheatreplan-2025-assistive-listeningWi-Fi discussionConsultancy reports measurements in some cases; no phone list, sample count, network conditions or method.Independent (Theatreplan, a UK theatre planning consultancy; written by its consultant Kit Lerman; no funding is stated)IndependentConsultancy reports measurements in some cases; no phone list, sample count, network conditions or method. theatreplan-2025-assistive-listening: A consultancy blog post without references. The Wi-Fi latency figure is given without its method, and the statements on infrared are the author's assessment, not measurements. It describes UK practice.latency-0335
Infinium system to BA R1 receiverAuracastvenue systempath latency<40statedNo measurement method reported.2026source datewilliams-av-2026-infinium-manualSpecifications: Latency (System)MAN 297BManufacturer specification; other receivers may vary.Manufacturer (Williams AV)ManufacturerManufacturer specification; other receivers may vary. williams-av-2026-infinium-manual: Manufacturer guidance without test data. The range figure is for open space with the maker's own receiver, and the specifications list transmit power as programmable without giving its maximum. Revision MAN 297B, copyright 2026.latency-0336

Codebook

system_path

System, endpoints, or component to which the value applies. Unspecified models remain unspecified.

technology

Library technology label. Shared includes acoustic, wired, generic Bluetooth and mobile-internet paths that do not fit a venue technology label.

scope

venue system or shared-path evidence. The latter includes personal transmitters, personal amplification apps, remote microphones, general network tests and a talk-back path. It does not establish performance of a venue installation.

metric

The timing quantity; see the list below.

latency_ms

Value in milliseconds, preserving ranges and qualifiers. A plain number is the reported value; ~ means approximate, < means strictly less, <= means up to, > means greater, and a trailing + means longer values are possible. as low as 25 is a best-case claim, not an upper limit. up to 20 or more preserves an expressly open upper end. A negative latency change means a reduction. This column deliberately mixes numbers and qualified text; parse the qualifier before numerical analysis.

evidence

measured if the source reports an observation or test; stated for specifications, estimates, calculations or timing settings. measured does not imply an independent test or a published method.

method

Measurement procedure where available. Missing methods are stated explicitly; methods from a different experiment in the same source are not substituted.

date

Measurement date or interval when given, otherwise source date. Uses YYYY-MM-DD, YYYY-MM, YYYY, YYYY-MM-DD/YYYY-MM-DD, or undated. Reduced precision avoids invented first-of-month days.

date_basis

Explains whether the date identifies measurements, an event, or the source. A source publication date is not treated as a test date.

source_id

Library source identifiers supporting the row, separated by semicolons. Feature-specific and supporting-source columns retain their more precise roles.

source_locator

Original page, section, table or model entry supporting the row; source names identify locations when several originals are used.

configuration

Sample rate, mode, firmware or measurement route when available. Workbook paths also retain firmware and assistant details. An empty field means no additional configuration was transcribed.

notes

Limits, attribution, timing direction, conflicts, overlapping summaries and sample size where reported.

funding_detail

Funding and producer context retained from the earlier compilation; the funding column carries the current source-record labels.

funding

Source-record funding labels. With multiple primary sources, each label is followed by its source id in brackets. Funding detail remains in funding_detail where supplied by the earlier compilation.

limitations

Row-specific interpretation limits and source-record reading limits. Missing information is not reported, never an inferred zero.

row_id

Permanent row identifier for links and question references. Keep it when correcting or moving a row; give new rows new ids and never reuse retired ids.

Compilation and interpretation

latency.csv was compiled on 2026-10-13 from the library and its private archived originals. It contains 336 rows from 32 existing source records. Its dates describe historical evidence; compilation does not establish current product performance.

The file is UTF-8, comma-separated, with one header row and standard CSV quoting. Each row represents one reported value or range for a specified path or timing quantity. Repeated values can belong to different firmware, sample rates, input routes, receivers, or sources. The Pro Audito workbook's numeric cells are retained individually, with additional rows for later readings in its comments (Pro Audito Schweiz 2025).

The metric values are:

  • path latency: a stated or measured signal-path delay; the endpoints may be incomplete in the source.
  • component latency: a delay in a specified part of a longer path.
  • relative arrival offset: timing difference between the stream and room sound, with direction in notes where known.
  • acoustic travel time: sound propagation through air.
  • network round-trip time: the network's request-and-response timing, without audio playback.
  • video latency: input-to-picture delay, relevant to sound/picture alignment.
  • latency change: an increase or decrease relative to another reading or firmware.
  • timing parameter: a supported setting, transport limit or adjustable added delay.
  • study summary: a range or bound that overlaps individual observations, or a synopsis without individual results.

Filter by metric, scope and evidence before comparing systems. Do not total rows or calculate a technology average: summaries overlap underlying results, paths have different endpoints, and many statements give no test method. Presentation Delay is a receiver timing parameter, and the general Wi-Fi study reports percentiles of one-minute averages of second-ping round-trip times; neither is a measured microphone-to-ear delay (Bluetooth SIG Generic Audio Working… 2026; Sui et al. 2016).

The outdoor report's relative-arrival rows are labelled stated: its differences are derived from system latency and the 25–100 ms front/back sound-travel reference. Its 18–57 ms and 29–46 ms Auracast entries are the printed front/back differences. They are retained as reported and are not asserted to be the minimum and maximum across all listener positions. For Auracast the stream is later at the front endpoint and earlier at the back, so the signals can coincide between them. The Pilatus Arena entry is a measured stream-leading offset at a rear seat (Pro Audito Schweiz 2026; Pro Audito Schweiz 2025).

The Pro Audito workbook has inconsistencies between conclusions, matrix cells and comments. The CSV preserves the cell-level readings and marks unresolved attribution. Matrix values for the Bettear receiver can represent initial or elevated delay. Additional comment readings are separate observations, not extra devices or independent experiments. The setup sheet gives 25 August–5 September 2025, but some comments were edited later; edit timestamps have not been converted into test dates. Model spelling follows the workbook apart from whitespace normalization and shortening the Starkey row label to Starkey Edge hearing aid, identified by its original source cells (Pro Audito Schweiz 2025).

Listener-tolerance thresholds, legal limits, stimulus delays in perception experiments, frame durations, advertising intervals, joining times and qualitative statements without a millisecond value are outside this signal-path dataset. The research report records these exclusions. There is no isolated measured phone-to-hearing-aid Bluetooth value in the retained evidence: the 350 ms pilot covers the complete Wi-Fi-device/phone/hearing-aid path and attributes most of its delay to the last hop without quantifying that hop (McWeeny et al. 2025).

The citation audit added supporting passages or corrections to nine existing source records. No question titles or summaries changed, so German summaries and question source counts remain unchanged. Private originals remain in the archive specified by AGENTS.md; they are not included in this directory.

Change log

  • 2026-10-13: Migrated 336 rows with codebook and source provenance into the data section.
  • 2026-10-14: Added permanent row ids for question references; existing cell values are unchanged.
  • 2026-10-14: Corrected the selected Aarau row’s audience and timing scope and the Auri RX1 row’s context and source locator after an archive audit.

Cite this table

Equal Access Audio. “Latency” Assistive Listening Knowledge Base. Version 2.1. Compiled 13 October 2026; updated 14 October 2026. https://assistivelisteningknowledgebase.org/data/latency/ (accessed the date you read it).