Measured and checked hearing loops

Installation checks and grouped loop findings, preserving methods, locations, outcomes, sample units and reporting limits.

  • 60 rows
  • 17 sources
  • Compiled 13 October 2026
  • Updated 14 October 2026
  • Version 1.2
  • Source dates: 18 July 2005 – 31 March 2026

Data licence: CC0 1.0 (public domain dedication).

Download CSV Download JSON

Reading the results

Rows distinguish installations or assessed areas, locations with uncertain equipment status, and aggregate findings. Availability, staff knowledge and listening checks do not establish measured field strength. Grouped results overlap some individual rows, and methods differ: do not pool counts or failure percentages. Reported repairs do not establish a measured retest. (Ciolek and Covington 2008; Healthwatch Hackney 2023; Lets Loop Southampton and Healthwatch… 2018; CHHA National 2023)

Column definitions · Compilation and interpretation · Change log

Scroll horizontally to read all columns. Empty cells mean no value was recorded; read each row’s notes and limits with its results.

Measured and checked hearing loops — 60 rows
Result IDRow scopeSiteSite typeCountryYearSource yearCheckedResultMethodMethod detailChecker typeCheckerSampleSource IDSource locatorFunding detailLimitationsFunding
alfakir-2015-lecture-hallinstallation_or_areaUnnamed lecture hallLecture hallnot reportednot reported2015Field strength at six seating locationsAuthors report loop field strength within +/-3 dB at all six tested seating locations.meterContacta Loop-FSM; six randomly chosen seating locations checked before the listener study. The Method describes locations measured from a reference point in the room centre.researcherAlfakir and colleaguesSix measurement locations; listener study had 12 participants initially and seven returning for session two.alfakir-2015Method, first two paragraphs and session counts; Discussion, opening paragraph; Acknowledgments and FundingIndependent (University of Florida and University of Oklahoma; the authors report no financial support and no conflicts of interest; Contacta, a loop maker, lent the field strength meter)The Discussion places the hall at a retirement community centre; its name, country and measurement dates are not reported. No complete field map or frequency-response/noise results. Authors cite ANSI/ISA-62382-2012; that reference is not substituted with an assumed hearing-loop standard.Independent
alva-2013-scottish-loops-all-venuesaggregateScottish visitor attractionsVisitor attraction ticket or information pointUnited Kingdom (Scotland)not reported2013Working loop at main ticket or information pointThree of 21 venues had working loops at the main ticket or information point. The other 18 are not split into missing and faulty loops.not reportedEquipment and procedure not reported.charity field teamAction on Hearing Loss Scotland, reported by ALVA/Attractions Management21 venues; three with working loops at the main ticket or information point.alva-2013-scottish-loopsArticle opening and named working-loop listTrade body (ALVA publishes Attractions Management news reporting Action on Hearing Loss Scotland’s charity-led checks; project funding is not stated)Includes the three individually named rows. Do not sum aggregate and individual counts. No test dates or equipment stated.Trade body
alva-2013-scottish-loops-mcmanusinstallation_or_areaMcManus Museum, DundeeVisitor attraction ticket or information pointUnited Kingdom (Scotland)not reported2013Working loop at main ticket or information pointWorking loop reported at the main ticket or information point.not reportedEquipment and procedure not reported.charity field teamAction on Hearing Loss Scotland, reported by ALVA/Attractions ManagementOne installation; listener count not reported.alva-2013-scottish-loopsArticle opening and named working-loop listTrade body (ALVA publishes Attractions Management news reporting Action on Hearing Loss Scotland’s charity-led checks; project funding is not stated)Secondary report published in December 2013; dates and methods of checks and individual checker roles not supplied. Three named positive cases selected from 21 venues; not a representative success sample.Trade body
alva-2013-scottish-loops-st-mungoinstallation_or_areaSt Mungo's Museum, GlasgowVisitor attraction ticket or information pointUnited Kingdom (Scotland)not reported2013Working loop at main ticket or information pointWorking loop reported at the main ticket or information point.not reportedEquipment and procedure not reported.charity field teamAction on Hearing Loss Scotland, reported by ALVA/Attractions ManagementOne installation; listener count not reported.alva-2013-scottish-loopsArticle opening and named working-loop listTrade body (ALVA publishes Attractions Management news reporting Action on Hearing Loss Scotland’s charity-led checks; project funding is not stated)Secondary report published in December 2013; dates and methods of checks and individual checker roles not supplied. Three named positive cases selected from 21 venues; not a representative success sample.Trade body
alva-2013-scottish-loops-stirlinginstallation_or_areaStirling CastleVisitor attraction ticket or information pointUnited Kingdom (Scotland)not reported2013Working loop at main ticket or information pointWorking loop reported at the main ticket or information point.not reportedEquipment and procedure not reported.charity field teamAction on Hearing Loss Scotland, reported by ALVA/Attractions ManagementOne installation; listener count not reported.alva-2013-scottish-loopsArticle opening and named working-loop listTrade body (ALVA publishes Attractions Management news reporting Action on Hearing Loss Scotland’s charity-led checks; project funding is not stated)Secondary report published in December 2013; dates and methods of checks and individual checker roles not supplied. Three named positive cases selected from 21 venues; not a representative success sample.Trade body
aohl-2013-visitor-attractions-attractionsaggregateLondon visitor attractionsVisitor attractionsUnited Kingdom (England)20122013Loop availability; working orderThree of 20 attractions had loops in good working order; of 11 advertising loops, seven actually had one.not reportedEquipment and procedure not reported.charity field teamAction on Hearing Loss20 attractions; separate advertised-loop subset of 11.aohl-2013-visitor-attractionsParagraph beginning Hearing loops are essential, containing the 2012 London findingsIndependent (Action on Hearing Loss reports its own checks; the article also promotes the charity’s equipment sales and access services; check funding is not stated)Work took place before the 2012 Olympics. No site-level results, equipment, field readings, listener sample or check funding stated. Article also promotes charity equipment and services.Independent
aph-2008-parliament-loop-audit-a1installation_or_areaParliament House, Canberra: Main committee room 1R0Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A1, printed p. 12Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a2installation_or_areaParliament House, Canberra: Committee room 1R0 galleryParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 20-80% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A2, printed p. 13Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a3installation_or_areaParliament House, Canberra: Committee room 1R1Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A3, printed p. 14Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a4installation_or_areaParliament House, Canberra: Committee room 1R2Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A4, printed p. 15Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a5installation_or_areaParliament House, Canberra: Committee room 1R3Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A5, printed p. 16Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a6installation_or_areaParliament House, Canberra: Committee room 1R4Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over less than 20% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A6, printed p. 17Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a7installation_or_areaParliament House, Canberra: Committee room 2R1Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over less than 20% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A7, printed p. 18Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a8installation_or_areaParliament House, Canberra: Committee room 2R2Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A8, printed p. 19Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a9installation_or_areaParliament House, Canberra: Committee room 2R3Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A9, printed p. 20Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a10installation_or_areaParliament House, Canberra: Committee room 1S2Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over less than 20% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A10, printed p. 21Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a11installation_or_areaParliament House, Canberra: Committee room 1S3Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A11, printed p. 22Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a12installation_or_areaParliament House, Canberra: Committee room 1S4Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A12, printed p. 23Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a13installation_or_areaParliament House, Canberra: Committee room 2S1Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A13, printed p. 24Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a14installation_or_areaParliament House, Canberra: Committee room 2S2Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A14, printed p. 25Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a15installation_or_areaParliament House, Canberra: Committee room 2S3Parliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A15, printed p. 26Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a16installation_or_areaParliament House, Canberra: House of Representatives floorParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A16, printed p. 27Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a17installation_or_areaParliament House, Canberra: House of Representatives gallery second westParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A17, printed p. 28Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a18installation_or_areaParliament House, Canberra: House of Representatives gallery first westParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A18, printed p. 29Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a19installation_or_areaParliament House, Canberra: House of Representatives gallery first northParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A19, printed p. 30Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a20installation_or_areaParliament House, Canberra: House of Representatives gallery first southParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A20, printed p. 31Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a21installation_or_areaParliament House, Canberra: Senate gallery second eastParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A21, printed p. 32Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a22installation_or_areaParliament House, Canberra: Senate gallery second northParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 20-80% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A22, printed p. 33Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a23installation_or_areaParliament House, Canberra: Senate gallery second southParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A23, printed p. 34Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a24installation_or_areaParliament House, Canberra: Senate gallery first eastParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A24, printed p. 35Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a25installation_or_areaParliament House, Canberra: Senate gallery first northParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A25, printed p. 36Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a26installation_or_areaParliament House, Canberra: Senate gallery first southParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A26, printed p. 37Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a27installation_or_areaParliament House, Canberra: TheatreParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 20-80% of the area. Assessment tied to the indicated labelling.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A27, printed p. 38Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a28installation_or_areaParliament House, Canberra: EPCR Blue RoomParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area. Appendix A28 reports above-normal hum from television studio lamps and mains wiring, rising sharply in the northeast corner.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A28, printed p. 39Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a29installation_or_areaParliament House, Canberra: Government party roomParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A29, printed p. 40Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a30installation_or_areaParliament House, Canberra: Opposition party roomParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: low base level and excessive signal attenuation; no coverage percentage assigned.meterLM Audio ILM12 loop monitor; grid readings after amplifier set-up; noise checked with loop amplifier off.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A30, printed p. 41Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Test dates not reported. First-draft report issued in 2008. Results generally follow amplifier adjustment. Coverage grades are the authors' categories; no full frequency-response test is reported. Noise readings use C weighting.Government
aph-2008-parliament-loop-audit-a31installation_or_areaParliament House, Canberra: Cabinet RoomParliamentary meeting areaAustralianot reported2008Field strength coverage; magnetic background noiseTable 1 grade: suitable signal level over 80-100% of the area.meterPartial meter check with low-level pink noise because of system integrity issues; earlier T4 commissioning is mentioned.governmentDepartment of Parliamentary Services broadcasting support staffOne of 31 audited areas in Parliament House.aph-2008-parliament-loop-auditTable 1, printed pp. 10-11; Appendix A31, printed p. 42Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)Table 1 gives the highest grade, but Appendix A31 explicitly limits this audit to a partial test. Do not treat the grade as a complete measured coverage result. Test date not reported.Government
chha-2023-yvr-counter-loops-kiosksaggregateVancouver International Airport: information kiosksAirport information countersCanada20222023Operational status; physical conditionInstaller found many systems not working or physically broken. Article reports restoration, redeployment and staff education the following year.not reportedEquipment and procedure not reported.installerAdvanced Listening Systems, original installer and later restorer2015 installation project comprised 13 kiosks; number failing in 2022 not given.chha-2023-yvr-counter-loopsVancouver International Airport section, first two paragraphsNonprofit advocacy (Canadian Hard of Hearing Association, in its Get in the Hearing Loop series; the check described was made by Advanced Listening Systems, the company that installed and later restored the loops)No kiosk-level results, failed-unit count or test procedure. No numerical verification after restoration; this is an advocacy account of installer work.Nonprofit advocacy
healthwatch-cornwall-2015-hospital-hearing-loss-maininstallation_or_areaRoyal Cornwall Hospital, Treliske: Trelawney main receptionHospital receptionUnited Kingdom (England)not reported2015Listening quality; acoustic background noise; signs; staff awarenessLoop worked, with poor sound through the hearing aid attributed to the lapel microphone and background noise; staff lacked suitable training.listeningHearing-aid listening at a hospital visit; no meter readings reported.governmentHealthwatch Cornwall; individual loop tester not identifiedTwo reception desks visited; number of loop listeners not specified.healthwatch-cornwall-2015-hospital-hearing-lossPDF pp. 1-2, Treliske loop-system bulletGovernment (Healthwatch Cornwall CIC, the county's statutory health and social care watchdog; the work followed issues raised by one of its volunteers who has hearing loss and a meeting with the hospital trust's equality lead)Report dated 9 April 2015; separate visit date not stated. Poor microphone pickup and acoustic background noise are not measurements of magnetic noise.Government
healthwatch-cornwall-2015-hospital-hearing-loss-outpatientsinstallation_or_areaRoyal Cornwall Hospital, Treliske: outpatients receptionHospital receptionUnited Kingdom (England)not reported2015Listening quality; acoustic background noise; signs; staff awarenessSimilar poor microphone pickup and background-noise issue to main reception; loop sign hidden behind a box and staff lacked suitable training.listeningHearing-aid listening at a hospital visit; no meter readings reported.governmentHealthwatch Cornwall; individual loop tester not identifiedTwo reception desks visited; number of loop listeners not specified.healthwatch-cornwall-2015-hospital-hearing-lossPDF pp. 1-2, Treliske loop-system bulletGovernment (Healthwatch Cornwall CIC, the county's statutory health and social care watchdog; the work followed issues raised by one of its volunteers who has hearing loss and a meeting with the hospital trust's equality lead)Report dated 9 April 2015; separate visit date not stated. Poor microphone pickup and acoustic background noise are not measurements of magnetic noise.Government
healthwatch-east-sussex-2024-gp-accessibility-surgeriesaggregateEastbourne GP surgery sitesGP reception and consultation roomsUnited Kingdom (England)20232024Loop availability; signs; reported staff knowledge and check proceduresFour of seven sites had reception loops and signs. The narrative says three of those four reported staff knew how to check operation, but the table gives a different breakdown. Only one site had regular checking procedures. One site had a portable loop.inspection/interviewLay checklist visits from July to October 2023, joined by surgery staff or patient representatives; no listening or meter test reported.government/volunteerHealthwatch East Sussex staff and volunteers, teams of two or threeSeven sites of five GP practices.healthwatch-east-sussex-2024-gp-accessibilityPrinted pp. 3-4, Methodology and Key findings; p. 6, Reception Area table; p. 9, Reception and waiting area; p. 11, CommunicationGovernment (Healthwatch East Sussex, the county's statutory health and social care watchdog; the audits were made by its staff and volunteers, with support from primary care commissioners at NHS Sussex)Availability and procedure audit, not proof that any installed loop worked. Sites selected from practices that replied. No site-level loop results. The staff-knowledge table gives one positive, one partially met, two negative and three not applicable, conflicting with the narrative's three affirmative reports; the report does not reconcile them.Government
healthwatch-hackney-2023-pharmacy-accessibility-pharmaciesaggregateHackney community pharmaciesPharmaciesUnited Kingdom (England)20222023Loop availability; staff awarenessSummary reports nine pharmacies with loops among 48 visited; at two of the nine staff were unaware of the loop or did not know how to use it.inspection/interviewChecklist visits in April 2022 by four authorised representatives; no listening or meter test reported.government/volunteerHealthwatch Hackney authorised representatives48 pharmacies signed up to the NHS Community Pharmacist Consultation Service.healthwatch-hackney-2023-pharmacy-accessibilityMethodology; Key findings - Accessibility within the premises - tools availability (PDF p. 11)Government (Healthwatch Hackney, the borough's statutory health and social care watchdog; the visits were made by four of its authorised representatives, and the report thanks the City and Hackney Local Pharmaceutical Committee for its support)Summary count transcribed without reconstructing individual equipment status from ambiguous availability/signage cells. This establishes reported availability and staff knowledge, not functioning loops.Government
healthwatch-southampton-2017-hospital-loops-c6location_checkUniversity Hospital Southampton: C6 TYA receptionHospital receptionUnited Kingdom (England)20172017Operation; staff awarenessReferred for investigation and staff training; loop type unknown. Sign difficult to see and attached to movable equipment.inspection/interview31 January 2017 visit with set staff questions and a questionnaire. The audit describes telecoil and loop-receiver listening overall, but gives no separate listening result for C6.volunteerHarry Dymond and Steve Beale, Healthwatch SouthamptonSix visited locations including three clinical receptions with uncertain loop status; two volunteers with hearing loss.healthwatch-southampton-2017-hospital-loopsPDF pp. 3-4, Method, Results and RecommendationsGovernment (Healthwatch Southampton, the city's statutory health and social care watchdog, funded through the local authority; the audit was done by two of its volunteers with hearing loss, as members of University Hospital Southampton's sensory loss group)Equipment status and signs discussed, but no separate listening result or confirmed equipment type published for C6. Do not code a demonstrated technical failure.Government
healthwatch-southampton-2017-hospital-loops-c7location_checkUniversity Hospital Southampton: C7 haematology day-unit receptionHospital receptionUnited Kingdom (England)20172017Operation; staff awarenessReferred for investigation and staff training; loop type unknown. Clearer sign and leaving the loop on during reception hours recommended.inspection/interview31 January 2017 visit with set staff questions and a questionnaire. The audit describes telecoil and loop-receiver listening overall, but gives no separate listening result for C7.volunteerHarry Dymond and Steve Beale, Healthwatch SouthamptonSix visited locations including three clinical receptions with uncertain loop status; two volunteers with hearing loss.healthwatch-southampton-2017-hospital-loopsPDF pp. 3-4, Method, Results and RecommendationsGovernment (Healthwatch Southampton, the city's statutory health and social care watchdog, funded through the local authority; the audit was done by two of its volunteers with hearing loss, as members of University Hospital Southampton's sensory loss group)Equipment status and signs discussed, but no separate listening result or confirmed equipment type published for C7. Do not code a demonstrated technical failure.Government
healthwatch-southampton-2017-hospital-loops-chapelinstallation_or_areaUniversity Hospital Southampton: chapelHospital chapelUnited Kingdom (England)not reported2017OperationRoom loop working correctly; effective use depends on the lectern microphone.listeningSeparately tested by Harry Dymond; date and equipment for this separate check not specified. The general Method describes Dymond using the telecoil setting.volunteerHarry Dymond, Healthwatch SouthamptonOne chapel room loop, checked by one volunteer; six locations represented across this audit's dataset rows.healthwatch-southampton-2017-hospital-loopsPDF pp. 3-4, Method, Results and RecommendationsGovernment (Healthwatch Southampton, the city's statutory health and social care watchdog, funded through the local authority; the audit was done by two of its volunteers with hearing loss, as members of University Hospital Southampton's sensory loss group)Chapel was checked separately by Harry Dymond; that check date is not given. No meter readings.Government
healthwatch-southampton-2017-hospital-loops-maininstallation_or_areaUniversity Hospital Southampton: main receptionHospital receptionUnited Kingdom (England)20172017Operation; staff awarenessWorking; staff familiar with it. Earlier incorrect installation had been redone. A small volume increase was recommended.listeningVisit on 31 January 2017; hearing-aid telecoil and loop receiver with earbuds; staff questionnaire. Chapel checked separately by one volunteer.volunteerHarry Dymond and Steve Beale, Healthwatch SouthamptonSix visited locations including three clinical receptions with uncertain loop status; two volunteers with hearing loss.healthwatch-southampton-2017-hospital-loopsPDF pp. 3-4, Method, Results and RecommendationsGovernment (Healthwatch Southampton, the city's statutory health and social care watchdog, funded through the local authority; the audit was done by two of its volunteers with hearing loss, as members of University Hospital Southampton's sensory loss group)No meter readings. Therapies was reported faulty but not visited; the shared outpatient reception is one loop, not two.Government
healthwatch-southampton-2017-hospital-loops-outpatientsinstallation_or_areaUniversity Hospital Southampton: shared cardiothoracic and oncology receptionHospital receptionUnited Kingdom (England)20172017Operation; staff awarenessWorking; volunteers had previously found it not working and shown staff how to use it. No further action recommended at this visit.listeningVisit on 31 January 2017; hearing-aid telecoil and loop receiver with earbuds; staff questionnaire. Chapel checked separately by one volunteer.volunteerHarry Dymond and Steve Beale, Healthwatch SouthamptonSix visited locations including three clinical receptions with uncertain loop status; two volunteers with hearing loss.healthwatch-southampton-2017-hospital-loopsPDF pp. 3-4, Method, Results and RecommendationsGovernment (Healthwatch Southampton, the city's statutory health and social care watchdog, funded through the local authority; the audit was done by two of its volunteers with hearing loss, as members of University Hospital Southampton's sensory loss group)No meter readings. Therapies was reported faulty but not visited; the shared outpatient reception is one loop, not two.Government
healthwatch-southampton-2017-hospital-loops-wellcomelocation_checkUniversity Hospital Southampton: Wellcome Trust CRF receptionHospital receptionUnited Kingdom (England)20172017Operation; staff awarenessStaff believed a loop was present but no unit could be found; an electrical point suggested a counter loop. Cable presence was not established.inspection/interviewVisit and discussion with staff; no unit available for a listening test.volunteerHarry Dymond and Steve Beale, Healthwatch SouthamptonSix visited locations including three clinical receptions with uncertain loop status; two volunteers with hearing loss.healthwatch-southampton-2017-hospital-loopsPDF pp. 3-4, Method, Results and RecommendationsGovernment (Healthwatch Southampton, the city's statutory health and social care watchdog, funded through the local authority; the audit was done by two of its volunteers with hearing loss, as members of University Hospital Southampton's sensory loss group)An uncertain installation, not a confirmed broken loop.Government
healthwatch-southampton-2018-central-loops-all-shopsaggregateCentral Southampton shopsRetail counterUnited Kingdom (England)20172018Loop availability; operation included in audit questions39 of 295 locations (13%) had loops. The published total counts presence; no total of functioning loops is supplied.not reportedVisits checked availability and operation and asked about power, training, signs and routine tests; receiver or meter not specified.volunteerLets Loop Southampton trained volunteers295 shops visited; 39 fitted with loops.healthwatch-southampton-2018-central-loopsPrinted pp. 6-7, Methodology and ResultsIndependent (Lets Loop Southampton and Healthwatch Southampton volunteer audit; separate audit funding is not specified; the report describes a £4,000 GoSouthampton contribution for businesses to obtain loops)No field-strength measurements or equipment-level follow-up readings. Aggregate rows overlap the named examples; do not add their counts.Independent
healthwatch-southampton-2018-central-loops-asdainstallation_or_areaASDA, central SouthamptonRetail counterUnited Kingdom (England)20172018Operation; signsLoop present but not operating correctly.not reportedVisits checked availability and operation and asked about power, training, signs and routine tests; receiver or meter not specified.volunteerLets Loop Southampton trained volunteersOne installation; listener count not reported.healthwatch-southampton-2018-central-loopsPrinted p. 7, table footnoteIndependent (Lets Loop Southampton and Healthwatch Southampton volunteer audit; separate audit funding is not specified; the report describes a £4,000 GoSouthampton contribution for businesses to obtain loops)No field-strength measurements or equipment-level follow-up readings. Aggregate rows overlap the named examples; do not add their counts.Independent
healthwatch-southampton-2018-central-loops-body-shopinstallation_or_areaThe Body Shop, central SouthamptonRetail counterUnited Kingdom (England)20172018Operation; signsLoop not working at the visit; the report later says it was repaired.not reportedVisits checked availability and operation and asked about power, training, signs and routine tests; receiver or meter not specified.volunteerLets Loop Southampton trained volunteersOne installation; listener count not reported.healthwatch-southampton-2018-central-loopsPrinted p. 7, Results and OutcomesIndependent (Lets Loop Southampton and Healthwatch Southampton volunteer audit; separate audit funding is not specified; the report describes a £4,000 GoSouthampton contribution for businesses to obtain loops)No field-strength measurements or equipment-level follow-up readings. Aggregate rows overlap the named examples; do not add their counts.Independent
healthwatch-southampton-2018-central-loops-john-lewisaggregateJohn Lewis, Southampton: three affected loopsRetail counterUnited Kingdom (England)20172018Operation; signsMarch 2017 audit found problems with three loops and missing signs. Report says the loops were repaired and signs added.not reportedVisits checked availability and operation and asked about power, training, signs and routine tests; receiver or meter not specified.volunteerLets Loop Southampton trained volunteersThree affected loops; total installed number not given.healthwatch-southampton-2018-central-loopsPrinted p. 8, John Lewis case studyIndependent (Lets Loop Southampton and Healthwatch Southampton volunteer audit; separate audit funding is not specified; the report describes a £4,000 GoSouthampton contribution for businesses to obtain loops)No field-strength measurements or equipment-level follow-up readings. Aggregate rows overlap the named examples; do not add their counts.Independent
healthwatch-southampton-2018-central-loops-stadiuminstallation_or_areaSt Mary's Stadium, Southampton: ticket officeStadium ticket counterUnited Kingdom (England)not reported2018Reported ticket-office loop quality; loop provisionExisting ticket-office loop described as poor quality. Report later describes improvements and more than 20 loops installed at the stadium.not reportedStadium visit and discussion after contact arising from the March 2017 Saints Store audit; the stadium check's equipment and procedure are not described.volunteerLets Loop Southampton trained volunteersOne installation; listener count not reported.healthwatch-southampton-2018-central-loopsPrinted p. 9, St Mary's Stadium case studyIndependent (Lets Loop Southampton and Healthwatch Southampton volunteer audit; separate audit funding is not specified; the report describes a £4,000 GoSouthampton contribution for businesses to obtain loops)Stadium visit followed contact arising from a March 2017 shop audit; its own date is not given. No test equipment, numeric readings or follow-up checks published.Independent
karg-2005-quality-controlled-loops-casino-theaterinstallation_or_areaCasino Theater, WinterthurTheatreSwitzerlandnot reported2005Frequency responseKarg describes the theatre loop response as within +/-3 dB from 100 Hz to 5000 Hz.measurement reportedPresentation text describes the frequency-response graph on slide 11; underlying readings and measurement equipment not included.not reportedMeasurement operator not named; result described by Siegfried KargOne installation; listener count not reported.karg-2005-quality-controlled-loopsPDF p. 2, commentary on slides 8 and 11Nonprofit advocacy (Siegfried Karg, then vice president of the European Federation of Hard of Hearing People and president of Pro Audito Winterthur, a Swiss hearing-loss association; the text is hosted on EFHOH's website)2002 is the renovation year, not an established test date. Talk published in 2005; slide graph and raw readings absent from the archived commentary. The speaker's separate 90% estimate is a guess and is excluded.Nonprofit advocacy
listen-2026-st-mauritius-case-study-churchinstallation_or_areaSt. Mauritius Church, BergPlace of worshipSwitzerlandnot reported2026Field-strength uniformity; commissioningManufacturer Ampetronic | Listen Technologies reports measurements and verification for uniform magnetic field strength across the listening area; no numerical results published.measurement reportedInstallation measurements and commissioning described without instrument, grid or test signal.installermuribaer sa, with project lead and Ampetronic engineering supportOne installation; listener count not reported.listen-2026-st-mauritius-case-studyPDF p. 2, RESULTManufacturer (Ampetronic | Listen Technologies, which made both the loop driver and the Auracast transmitter described)Manufacturer account of its own equipment; no field map, frequency-response or noise figures, independent check or listener sample. Document version is dated 2026; actual test date is not given.Manufacturer
london-assembly-2016-sensory-travel-routemasterinstallation_or_areaNew Routemaster bus on London Assembly site visitBusUnited Kingdom (England)20162016Audible coverage; interferenceUnpleasant buzz especially behind the driver's cab near an electrical cabinet; loop audible in priority seats nearest the middle door but not in those across the aisle.listening25 February 2016 journey with two hearing-aid users, shadowed by the committee chair.government/listenerLondon Assembly Transport Committee chair and two hearing-aid usersOne bus journey; two hearing-aid users.london-assembly-2016-sensory-travelPrinted pp. 6-7, 20 and Appendix B p. 27Government (London Assembly, the elected body that scrutinises the Mayor of London and Transport for London)Vehicle number and route not identified. No meter readings; not a finding about all Routemaster buses.Government
magann-faivre-2016-lecture-hallinstallation_or_areaUniversity lecture hall: 7 x 3 m test loop in a 120-seat roomLecture hallnot reportednot reported2016Field strength; frequency response; electrical noise; speech recognitionManufacturer-funded study reports meter checks without numerical loop readings. Hearing-aid users' HINT word-correct scores rose from 14% to 88% at -3 dB SNR and from 52% to 89% at +3 dB SNR with the loop on.meter and listeningField-strength meter with vertical telecoil; loop-on/off HINT testing. Room noise of 43 dBA is acoustic, not magnetic noise.researcher/installerMagann Faivre and colleagues; Steve Thunder assisted installation and technical support26 bilateral hearing-aid users and 45 normal-hearing listeners; one lecture hall.magann-faivre-2016Study Methods: Testing Site and Hearing loop calibration; Discussion; AcknowledgementsManufacturer (the authors state the research was funded by GN ReSound, a hearing aid maker, and Listen Technologies, an assistive listening and loop maker, together with the David & Carol Myers Foundation, the family foundation of loop advocate David Myers; study run at Northern Illinois University; co-author Juliëtte Sterkens is a hearing loop advocate whose outreach that foundation funds)Actual test dates and explicit hall location not stated. Portions presented in October 2013; 2016 is publication year. Temporary 21-square-metre test loop does not establish whole-hall coverage. Speech results depend on listeners and fittings as well as installation.Manufacturer
ridc-2022-orr-help-points-help-pointsaggregateRailway station Help Points in Great BritainRailway station help pointsUnited Kingdom (Great Britain)2020; 20212022Auditor assessment of whether a working loop was present81.8% agreed and 18.2% disagreed that there was a working hearing loop.not reportedMystery-shop journeys and questionnaire; how loop operation was judged is not stated.consumer auditorRiDC consumer panel for the Office of Rail and Road22 loop-question answers within 147 station audits by 63 auditors, including four expert reviewers.ridc-2022-orr-help-pointsExecutive summary, Methodology and Context; Appendix 2 Table L, printed p. 77; Appendix 3, printed p. 79Government (commissioned by the Office of Rail and Road, Great Britain's rail regulator, from the Research Institute for Disabled Consumers, which ran the audits with its panel of disabled consumers; the report states that it is independent)Overall fieldwork began February 2020 and resumed September 2021; individual loop-check dates not separated. No meter or telecoil procedure stated. These 22 answers are not a failure-rate estimate for all 147 stations.Government
rnid-2009-loop-checks-reportsaggregateUK businesses in RNID campaign reportsPost offices; supermarkets; banks; shops; theatresUnited Kingdom20092009Operation; availability; staff training; switched-on statusNearly half of 500 reports described a loop not working properly; nearly one in four described no loop. Other complaints included lack of training and loops switched off.not reportedEquipment and procedure not reported.volunteerRNID campaigning volunteers, reported by Disability News Service500 reports covering 210 separate businesses since the start of 2009.rnid-2009-loop-checksArticle opening three paragraphsNonprofit advocacy (reports gathered by campaign volunteers of the UK charity RNID and released for its Deaf Awareness Week campaign; reported by Disability News Service; labelled advocacy rather than an independent test because the reports were gathered for a campaign, with no test protocol described in the news report)Reports are not unique installations. Campaign sampling and test method not described; do not infer a meter or listening method or a population failure rate.Nonprofit advocacy
seidler-2012-daga-roominstallation_or_areaUnnamed reverberant room, seats 260 and 464Assembly roomnot reportednot reported2012Speech Transmission Index (STI-PA)Loop condition exceeds 0.75 at both seats, the figure's excellent-intelligibility category; other conditions plotted below it.measurement reportedSTI comparison at two seats with unaided listening, hearing aids, sound system plus hearing aids and loop; instrument unspecified.researcherMeasurements reported by Hannes SeidlerTwo seats in one room; not a reported listener sample.seidler-2012-dagaPrinted p. 97, Nutzen induktiver Hoeranlagen and Figure 1Independent (TU Dresden, ear, nose and throat clinic of the Carl Gustav Carus university hospital); funding not statedCountry, venue name and measurement dates not supplied. Figure cites earlier 2009 work. Values not digitised from bars; no inferred precise scores. Not a field-strength or frequency-response test.Independent

Codebook

result_id

Unique source-based key and installation, area or aggregate suffix. Parliament suffixes match Appendix A references.

row_scope

installation_or_area, location_check for uncertain equipment status, or aggregate when only grouped evidence is available.

site

Named installation/location or the source's group description. Unnamed rooms stay unnamed.

site_type

Venue setting, such as hospital reception, bus or theatre.

country

Source-supported location, with UK nation where available. Author affiliations do not establish a test site's country.

year

Year of the check only, or not reported. 2020; 2021 denotes RiDC's two fieldwork periods, not two checks of each installation.

source_year

Library publication year; never silently substituted for the check year.

checked

Quantities or features actually measured or examined. Availability, signs and staff knowledge are distinguished from operation.

result

Source-attributed outcome, including numerical values, faults and reported repairs. A repair account does not imply a measured retest.

method

meter, listening, meter and listening, inspection/interview, measurement reported, or not reported. The fifth value means measurements are described but equipment/procedure details are insufficient to classify further.

method_detail

Equipment, procedure and exact dates where stated. No meter or listening method is inferred merely from the word check.

checker_type

Actual checker role where known; combined roles use /. It is separate from funding and from the organisation publishing the account.

checker

Named checker or team; where only the reporting author is known, the cell says so.

sample

Area, venue, report, measurement-point or participant denominator with its unit preserved. These units are not interchangeable.

source_id

Library source identifiers supporting the row, separated by semicolons. Feature-specific and supporting-source columns retain their more precise roles.

source_locator

Original page, section, table or model entry supporting the row; source names identify locations when several originals are used.

funding_detail

Funding and producer context retained from the earlier compilation; the funding column carries the current source-record labels.

limitations

Row-specific interpretation limits and source-record reading limits. Missing information is not reported, never an inferred zero.

funding

Source-record funding labels. With multiple primary sources, each label is followed by its source id in brackets. Funding detail remains in funding_detail where supplied by the earlier compilation.

Compilation and interpretation

loop-tests.csv was compiled on 2026-10-13 from 17 existing library records and their archived originals. It contains 60 rows: 48 individual installations or assessed areas, three checked locations where equipment status was uncertain, and nine explicitly labelled aggregate findings.

The normal unit is one installation or assessed area, combining its checks in one row. Parliament House has 31 area rows keyed to the audit's A1-A31 references; these are not asserted to be 31 electrically separate systems. Where a source supplies only grouped findings, an aggregate row preserves that evidence without inventing individual installations. Filter row_scope before analysing individual results. The Scottish total includes its three named rows, and Southampton's overall shop audit includes its named shop examples. Neither totals nor failure percentages should be pooled across these overlapping rows or across unlike methods. (Ciolek and Covington 2008; Association of Leading Visitor… 2013; Lets Loop Southampton and Healthwatch… 2018; Disability News Service 2009; CHHA National 2023)

The file is UTF-8, comma-delimited, with a header, quoted fields and LF line endings. Import as text to preserve qualifiers and multiple years. not reported denotes missing information, never zero. There are no formulas, converted units or graph-digitised point estimates. Rows sort by source id and result id, with numeric area suffixes in numerical order.

Parliament's coverage categories are the audit authors' classifications after amplifier adjustment, not complete tests of every standard parameter. The Cabinet Room's highest Table 1 grade is retained with its partial-test qualification. Hospital listening quality and bus interference observations are not substituted for field-strength measurements. Hackney and Eastbourne rows describe availability and staff procedures, without proving working audio. Eastbourne's staff-knowledge narrative conflicts with its table; the row preserves that uncertainty. The Southampton therapies loop was not visited and is excluded from the check rows. C6 and C7 have no separately reported listening result, and the chapel's check was separate from the dated main visit. (Ciolek and Covington 2008; Healthwatch Cornwall 2015; London Assembly Transport Committee 2016; Healthwatch Hackney 2023; Healthwatch East Sussex 2024; Dymond HF 2017)

The q26 research report lists coverage decisions, archive provenance, uncertainties and existing-record concerns. Updating this table requires re-reading the original, retaining the row's unit and method, and distinguishing an actual retest from a later publication or repair claim.

Change log

  • 2026-10-13: Migrated 60 rows with codebook and source provenance into the data section.
  • 2026-10-14: Declared the existing row key for stable links from questions; row values are unchanged.
  • 2026-10-14: Corrected the Alfakir row’s location limit and added the Discussion and session-count locators after an archive audit.