Assistive Listening Knowledge Base
  • Manufacturer user manual

PLM FSMP Field Strength Meter (FSM): User Manual, MAN 204D

  • Williams AV

Manufacturer (Williams AV, which sells the meter and hearing loop drivers)

Summary

Williams AV's seven-page manual for its handheld loop field-strength meter gives two measuring ranges, two filters, the use position and a frequency-response specification.

Key findings

  • Pages 3-4 describe two ranges selected by a switch: a 0 dB range for loop field strength and a -20 dB range of higher sensitivity for background noise and magnetic interference, covering -43 to -12 dB. Filter A weights readings by the hearing curve; Filter Norm leaves them unweighted.
  • The page 3 scale shows the LED steps: 1 dB steps from +5 to -4 (and from -15 to -24 on the noise range), then -6, -8, -10, -13 and below -15 (-26, -28, -30, -33 and below -43 on the noise range).
  • Page 4 asks the user to choose a reference point, usually in the middle of the loop, hold the meter perpendicular to the floor and note the height, typically 1.20 m seated or 1.70 m standing. Commissioning steps are left to the loop amplifier's own manual.
  • Page 7 specifies true RMS measurement at 125 ms; 0 dB = 0.4 A/m and -20 dB = 0.043 A/m; and a frequency response (filter A / flat) of -3 to -4 dB from 30 to 500 Hz, ±0.25 dB from 500 to 2,500 Hz and ±3 dB from 2,500 Hz to 10 kHz.
  • Page 5 says the meter needs no maintenance beyond cleaning. The manual gives no calibration accuracy, calibration procedure or recalibration interval.
  • The linked product page (read the same day) says the meter conforms to the IEC 60118-4:2006 standard, gives a measuring range of +6 to -40 dB re 400 mA/m and an LED scale with 1 dB resolution, and lists a 3.5 mm headphone jack for listening to the loop.

Limits

A maker's manual for its own meter, with no test data or comparison with other meters. The PDF prints MAN 204D and a 2024 copyright while its file name says 204E. The manual's weight (about 300 g) differs from the product page and spec sheet (170 g), and its scale steps below -4 dB are coarser than the 1 dB resolution the product page states. The 2006 edition of IEC 60118-4 named on the product page was replaced in 2014.

Read the original

williamsav.com/wp-content/uploads/2020/04/MAN-204E-PLA-FSMP-Field-Strength-Meter.pdf

Link checked . We link to the original and do not host copies.

Cited in

Cite this source

Williams AV. PLM FSMP Field Strength Meter (FSM): User Manual, MAN 204D. 2024. https://williamsav.com/wp-content/uploads/2020/04/MAN-204E-PLA-FSMP-Field-Strength-Meter.pdf (accessed 5 November 2026).

The accessed date is when this library last checked the link; use the date you read it. To point readers to this summary instead, link to https://assistivelisteningknowledgebase.org/evidence/williams-av-2024-fsm-manual/

Every finding here cites its source, and who funded each source is labelled. This site does not recommend products. Found an error or a missing study? Suggest a correction.