Loop Configurations Explained: why one size does not fit all

  • UnivoxAudio Ltd
  • UnivoxAudio (knowledge centre wiki)

Manufacturer (UnivoxAudio Ltd, the UK and Ireland distributor of the Swedish loop maker Bo Edin's Univox amplifiers and SuperLoop systems, which the page describes and sells)

Summary

A loop distributor's guide to perimeter, cancellation, figure-of-eight and array loops, with its rules of thumb on how far a loop's field spills and how metal in floors limits a simple loop's width.

Key findings

  • Says a perimeter loop is the easiest and, where it works, cheapest layout, but that large areas, spill control or metal loss can rarely be handled with one.
  • Warns never to install a perimeter loop at listening height: in its example, 0.25 m vertically from the loop, the field was about -1 dB at the centre of the room and over +9 dB at the edge, outside the standard's tolerance; the further the loop is from the listening plane, the more even the field.
  • Gives the widest floor-level perimeter loop as about 22 m for seated listeners (listening plane 1.2 m) and 26 m for standing listeners (1.7 m) with no metal; over standard reinforced concrete 6-10 m (5-9 m standing), heavy reinforced concrete 3-6 m (2-5 m), a metal system floor or steel deck 1-3 m (2-3 m), and under a glass or metal suspended ceiling 3 m.
  • Says a perimeter loop's spill field extends one to two times its width, with a signal above -32 dB (the background noise level it treats as the limit) still present there, so a 5 m loop may still radiate above that level 5-10 m away.
  • Says metal loss correction flattens the response at only one point, so in larger loops some areas stay under-corrected and others over-corrected; where the field varies by more than 6 dB, smaller multiple loops are needed. Moving the loop away from the metal, for example to ceiling level, is offered as another remedy.
  • Describes a cancellation loop as a simple, relatively low-cost way to cut spill in one or two directions, at the price of part of the room lacking full coverage.

Limits

A distributor's guide based on its own design tools and products, with field plots but no measured sites or data behind its width table and spill figures. The page shows no date; it refers to IEC 60118-4:2006, since replaced by the 2014 edition, and the site footer gives copyright 2012.

Read the original

www.univoxaudio.co.uk/knowledge-centre-wiki/a-guide-to-induction-loops/loop-configurations

Link checked . We link to the original and do not host copies.

Cited in

Cite this source

UnivoxAudio Ltd. Loop Configurations Explained: why one size does not fit all. UnivoxAudio (knowledge centre wiki). n.d. https://www.univoxaudio.co.uk/knowledge-centre-wiki/a-guide-to-induction-loops/loop-configurations (accessed 9 October 2026).

The original gives no date, so the citation says “n.d.”. The accessed date is when this library last checked the link; use the date you read it. To point readers to this summary instead, link to https://assistivelisteningknowledgebase.org/evidence/univox-loop-configurations/

Every finding here cites its source, and who funded each source is labelled. This site does not recommend products. Found an error or a missing study? Suggest a correction.