A personal remote microphone reduced response times in some listening positions for children with limited hearing in one ear.
Key findings
- Nineteen children aged 7–12 with limited usable hearing unilaterally were recruited. One child’s data were excluded as unreliable, leaving 18 analysed.
- A personal digital remote-microphone system, a contralateral routing system and unaided listening were compared on digit recognition and verbal response time with different speech/noise directions.
- The remote microphone improved digit recognition in all three loudspeaker arrangements and shortened response times in the midline and indirect arrangements, but not significantly in the direct arrangement.
- Self-reports favoured the remote microphone for ease and motivation in the midline and indirect arrangements. The microphone always remained near the target loudspeaker; head movement was constrained.
Limits
Full original article XML read. Sonova funding, small paediatric sample, one difficult noise level, and possible self-report response bias. Personal remote microphones are outside the venue-system scope; used only as evidence about capturing speech close to the talker and delivering it to the listener.
Read the original
doi.org/10.1177/2331216520984700
Cited in
Cite this source
Oosthuizen I, Picou EM, Pottas L, Myburgh HC, Swanepoel W. Listening Effort in School-Aged Children With Limited Useable Hearing Unilaterally: Examining the Effects of a Personal, Digital Remote Microphone System and a Contralateral Routing of Signal System. Trends in hearing. 18 February 2021. https://doi.org/10.1177/2331216520984700 (accessed 27 October 2026).