Summary
Ampetronic's guide to hearing loops in offices: boardrooms, adjacent and divisible meeting rooms, connection to presentation and conferencing equipment, reception points and lifts.
Key findings
- Page 5: says hearing aids work well one to one, but difficulties arise when ambient noise is high, as in an open office, or when distance grows, as in a meeting room or conference hall; problems are worse in partitioned multipurpose rooms, where spill causes interference, and where there is metal in the structure.
- Page 8: for smaller office spaces without metal and with no other systems close by, recommends a perimeter loop; for metal in the structure, a low-loss phased array; for nearby rooms or to limit spill from "sensitive meetings", low-spill arrays.
- Page 11: low-spill arrays in divisible rooms can run independently with the divider closed and combine as one system when the space is opened, for training, conferences and breakout activities; low-spill loops are also used between rooms "to maintain confidentiality".
- Page 14: asks that all audio services in a room be connected to the loop so hearing aid users miss no part of a meeting or presentation, by connecting the AV system's line out to the loop driver's line input; for a many-to-many conference room it recommends fitting the loop as part of a conferencing sound reinforcement system so that only one voice is transmitted at a time.
- Page 7: notes that the number of users is limited only by how many people fit in the looped area and that loop listeners need no receiver, only the hearing aid's T setting.
- Page 19: says loops are "invisible and inaudible" to potential users, so signs are needed.
Limits
A maker's application guide promoting its own products, with named-company installations given as examples and no measurements. It predates Auracast and current conferencing platforms and does not describe a video-conferencing feed. The copyright line reads 2017; the file sits in a 2019 upload folder.
Read the original
d1otu1v6uwxjcy.cloudfront.net/wp-content/uploads/2019/02/UP30082-2-Corporate_App_Notes-.pdf
Cited in
- What do employers have to provide for staff with hearing loss in meetings and workplaces, and which systems work there?Partly answered
Cite this source
Ampetronic. Corporate: Hearing loops application guide. Ampetronic (document UP30082-2). 2017. https://d1otu1v6uwxjcy.cloudfront.net/wp-content/uploads/2019/02/UP30082-2-Corporate_App_Notes-.pdf (accessed 5 November 2026).
Every finding here cites its source, and who funded each source is labelled. This site does not recommend products. Found an error or a missing study? Suggest a correction.