 "name": "range",
 "title": "Range and coverage",
 "summary": "Range and coverage findings across venue systems, with settings, receivers, evidence types, conditions and source limits.",
 "url": "https://assistivelisteningknowledgebase.org/data/range/",
 "compiled": "2026-10-13",
 "updated": "2026-10-14",
 "version": "1.0",
 "licence": "https://creativecommons.org/publicdomain/zero/1.0/",
 "technologies": [
  "Auracast",
  "Hearing loops",
  "Infrared",
  "RF/FM",
  "Shared"
 ],
 "affects": [
  "Installers",
  "Specifiers"
 ],
 "changes": [
  "2026-10-14: Made the funding and producer context explicit in the cited range interpretation notes.",
  "2026-10-13: Migrated 126 rows with codebook and source provenance into the data section."
 ],
 "columns": [
  {
   "name": "result_id",
   "meaning": "Unique key formed from the source id and a result suffix. Hall suffixes identify original workbook cells; Parliament House suffixes identify Table 1 area references."
  },
  {
   "name": "technology",
   "meaning": "Library technology label. `Shared` identifies cellular streaming or its final personal Bluetooth link; these rows are not Wi-Fi coverage evidence."
  },
  {
   "name": "system",
   "meaning": "Transmitter, installed system or signal path, including firmware where the source supplies it."
  },
  {
   "name": "setting",
   "meaning": "Venue and occupancy/environment as reported. Absence of event interference does not establish an audience count."
  },
  {
   "name": "distance_or_area",
   "meaning": "Original distance, dimensions, coverage band, seating extent or a statement that the extent is unknown. Units and qualifiers stay with the value. Room size is context, not a measured radio range."
  },
  {
   "name": "outcome",
   "meaning": "Source-attributed reception result or stated specification, including failures and qualifications. Hall grades are preserved here."
  },
  {
   "name": "receiver",
   "meaning": "Tested or specified receiver/device, firmware and assistant path where provided. A list means the source reports a shared result without separate measurements for each device."
  },
  {
   "name": "evidence_type",
   "meaning": "Distinguishes observations, measurements, subjective listening grades, specifications, estimates and trade-body reports; definitions below."
  },
  {
   "name": "test_date",
   "meaning": "Actual test date only: `YYYY-MM-DD`, `YYYY-MM`, `YYYY`, or `not reported`. Publication dates are never substituted."
  },
  {
   "name": "source_date",
   "meaning": "Date of the cited publication or document version, at its supported precision, or `undated`. A linked manual can have a different date from its library record's main page."
  },
  {
   "name": "source_date_basis",
   "meaning": "Identifies publication, issue, version, copyright, file metadata or upload-folder dates and known revision ambiguity."
  },
  {
   "name": "source_id",
   "meaning": "Library source identifiers supporting the row, separated by semicolons. Feature-specific and supporting-source columns retain their more precise roles."
  },
  {
   "name": "source_locator",
   "meaning": "Original page, section, table or model entry supporting the row; source names identify locations when several originals are used."
  },
  {
   "name": "funding_detail",
   "meaning": "Funding and producer context retained from the earlier compilation; the funding column carries the current source-record labels."
  },
  {
   "name": "conditions",
   "meaning": "Method, power, mounting, channel count, sample or other conditions supplied by the source."
  },
  {
   "name": "limitations",
   "meaning": "Row-specific interpretation limits and source-record reading limits. Missing information is not reported, never an inferred zero."
  },
  {
   "name": "source_summary_inclusion",
   "meaning": "`included` or `excluded` only for the Pro Audito hall workbook's overall evaluation; `not applicable` elsewhere. Both excluded scored pairs remain in the CSV."
  },
  {
   "name": "scope",
   "meaning": "`venue system`, `venue system; cellular streaming`, or `shared-path comparison`. The last category includes consumer/personal transmitters tested in the hall and the phone-to-hearing-aid link after a venue stream; it is evidence about a shared path."
  },
  {
   "name": "funding",
   "meaning": "Source-record funding labels. With multiple primary sources, each label is followed by its source id in brackets. Funding detail remains in funding_detail where supplied by the earlier compilation."
  }
 ],
 "row_count": 126,
 "sources": [
  "ampetronic-listen-2025-hlaa-presentation",
  "aph-2008-parliament-loop-audit",
  "auri-2025-coverage-guide",
  "bettear-rtx",
  "bihima-2026-auracast-live-theatre",
  "bluetooth-sig-2025-qr-paper",
  "bluetooth-sig-2025-range-handout",
  "bluetooth-sig-2026-bethel-profile",
  "graf-2026",
  "listen-2010-72-vs-216",
  "listen-2022-lt82-ir-manual",
  "london-assembly-2016-sensory-travel",
  "opus-2025-auragate-datasheet",
  "opus-2025-auraloop",
  "phonak-2026-eon-connectivity",
  "pro-audito-2025-compat",
  "pro-audito-2025-operator-guidance",
  "pro-audito-2025-pilatus-arena",
  "pro-audito-2025-theatre-aarau",
  "pro-audito-2026-outdoor",
  "pro-audito-2026-venucast-test",
  "sennheiser-szi-1015",
  "sig-ropetackle-profile",
  "williams-av-2024-ir-t3-manual",
  "williams-av-2025-digi-wave-400-manual",
  "williams-av-2026-infinium-manual"
 ],
 "codebook": "## Reading the results\n\nRows distinguish measurements, listening grades, field observations, manufacturer specifications and estimates, and trade-body accounts. Room size, seating extent, coverage percentage and transmitter-to-receiver distance are different quantities. Read each result with its conditions and evidence type; rows from the same test are not independent replications. The outdoor cellular-streaming observations do not measure Wi-Fi range. [@pro-audito-2025-compat; @aph-2008-parliament-loop-audit; @opus-2025-auraloop; @pro-audito-2026-outdoor]\n\n## Compilation and interpretation\n\n`range.csv` was compiled and independently audited on **2026-10-13** against 26 existing library records and their archived originals. It contains 126 rows: individual hall-test pairs and audited loop areas, field observations, explicit numerical product claims, expert estimates, and attributed venue accounts. The audit added supporting passages and corrected source details in existing records. No new source records or question pages were added.\n\nThe file is UTF-8, comma-separated, with one header row, quoted fields and LF line endings. Import fields as text to preserve partial dates, qualifiers and source identifiers. `not reported` means the source does not provide that item; it never means zero. `not applicable` is reserved for a field that does not apply. No formulas or unit conversions are embedded.\n\n\n### Evidence types\n\n| Value | Meaning |\n| --- | --- |\n| `field measurement` | Instrumented result in an installed venue; here, the Parliament House loop audit. |\n| `listening test` | Reception graded by listening to a test signal; here, the Pro Audito hall matrix. |\n| `field observation` | First-hand reception report without a numerical measurement protocol for spatial coverage. |\n| `manufacturer-reported measurement` | A maker explicitly reports a test or measurement, but the underlying protocol/data are unavailable. |\n| `manufacturer specification` | Maker's stated range or area without a published test establishing it. |\n| `manufacturer estimate` | Maker's predicted change under a stated configuration. |\n| `expert estimate` | Practical estimate in expert guidance without a reported measurement series. |\n| `trade-body claim` | Generic range statement from a trade body. |\n| `trade-body venue report` | A trade body's account of a demonstration or venue experience, without independent coverage measurements. |\n\n### Reading the results\n\n- Independent hearing-loss association Pro Audito's hall workbook contains **53 scored pairs**. The association reports no manufacturer funding; manufacturers lent test products without charge. Nine score 1, eight score 2, nine score 3, eleven score 4 and sixteen score 5. Excluding H8 and J9 as its authors do leaves **51 pairs**, with **16 scoring 1 or 2** and **26 scoring 4 or 5**. Blank cells and row/column averages are not results. Grades 1 and 2 permit some dropouts or artefacts; they do not mean uninterrupted reception. Grade descriptions give approximate symptom distances, not a measured maximum range for each pair. Device labels retain source spellings except the expanded Williams name, whitespace, unknown-firmware wording, and the shortened Starkey Edge model label. Exact cells identify the original names. [@pro-audito-2025-compat]\n- The Government audit by Parliament House's own staff has **31 area rows**: nine assigned to the 80-100% category, three to 20-80%, three below 20%, and sixteen with low base level and excessive attenuation. The last category has no numeric coverage percentage. The Cabinet room is among the nine top grades, but Appendix A31 says it was only partially tested with low-level pink noise and refers to earlier commissioning. Its grade is not a complete measured coverage result from this audit. The general procedure adjusted amplifiers before measurement. These are the audit's signal-coverage grades, not a complete assessment against the loop standard. Measurement dates are unstated; 2008 is the report year. [@aph-2008-parliament-loop-audit]\n- Hall dimensions, seating capacity, percent coverage and transmitter-to-receiver distance are different quantities. Do not convert a 22 x 80 m room into an 80 m range, infer a coverage radius from a seat count, or pool these rows into a technology average. Multiple rows often come from the same test and are not independent replications. [@pro-audito-2025-theatre-aarau], [@pro-audito-2025-compat], [@bluetooth-sig-2025-qr-paper]\n- The outdoor 5G result describes venue-wide internet reception with high delay. Its separate phone-to-hearing-aid row records interruptions after that stage. Neither row measures Wi-Fi range. No spatial Wi-Fi measurement was found in the reviewed library material. [@pro-audito-2026-outdoor]\n- Manufacturer Opus's AuraLoop product page gives a 3 m loop range while its linked manual gives 1.10 m. Both claims are retained; their methods and thresholds are not stated. [@opus-2025-auraloop]\n\nThe table excludes legal coverage requirements, recommended transmitter spacing, loop-design width limits, simulations, overspill outside the intended listening area, installation inventories, operational audits without spatial results, receiver/user capacity and speech scores measured in a room without a coverage test. Repeated generic claims are represented by the more specific primary product source where available. The research note records exclusions and remaining gaps. Refresh by checking the source record and its archived original, preserving earlier dated results when conditions or firmware differ.\n",
 "rows": [
  {
   "result_id": "pro-audito-2025-compat--b2",
   "technology": "Auracast",
   "system": "Starkey TV-Streamer FW: not reported",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!B2; transmitter B1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--c2",
   "technology": "Auracast",
   "system": "Opus Auragate FW:2.1.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!C2; transmitter C1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--d2",
   "technology": "Auracast",
   "system": "Moor Moer SoundLinker FW:5.2.2",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!D2; transmitter D1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--e2",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer Low Latency FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!E2; transmitter E1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--f2",
   "technology": "Auracast",
   "system": "GN TV-Streamer + FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!F2; transmitter F1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--g2",
   "technology": "Auracast",
   "system": "Bettear B-CASTER FW:1.0.3",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!G2; transmitter G1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--h2",
   "technology": "Auracast",
   "system": "Listen Auri TX2N FW:1.5",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!H2; transmitter H1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--i2",
   "technology": "Auracast",
   "system": "GN MultiMic+ FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!I2; transmitter I1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j2",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "Starkey Edge FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J2; transmitter J1; receiver A2; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--c3",
   "technology": "Auracast",
   "system": "Opus Auragate FW:2.1.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!C3; transmitter C1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--d3",
   "technology": "Auracast",
   "system": "Moor Moer SoundLinker FW:5.2.2",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!D3; transmitter D1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--e3",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer Low Latency FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!E3; transmitter E1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--f3",
   "technology": "Auracast",
   "system": "GN TV-Streamer + FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!F3; transmitter F1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--h3",
   "technology": "Auracast",
   "system": "Listen Auri TX2N FW:1.5",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!H3; transmitter H1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--i3",
   "technology": "Auracast",
   "system": "GN MultiMic+ FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!I3; transmitter I1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j3",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "JBL Tour Pro 3 FW:4.9.6",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J3; transmitter J1; receiver A3; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--b4",
   "technology": "Auracast",
   "system": "Starkey TV-Streamer FW: not reported",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!B4; transmitter B1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--c4",
   "technology": "Auracast",
   "system": "Opus Auragate FW:2.1.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!C4; transmitter C1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--d4",
   "technology": "Auracast",
   "system": "Moor Moer SoundLinker FW:5.2.2",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!D4; transmitter D1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--e4",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer Low Latency FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!E4; transmitter E1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--f4",
   "technology": "Auracast",
   "system": "GN TV-Streamer + FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!F4; transmitter F1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--g4",
   "technology": "Auracast",
   "system": "Bettear B-CASTER FW:1.0.3",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!G4; transmitter G1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--h4",
   "technology": "Auracast",
   "system": "Listen Auri TX2N FW:1.5",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!H4; transmitter H1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--i4",
   "technology": "Auracast",
   "system": "GN MultiMic+ FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!I4; transmitter I1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j4",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J4; transmitter J1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--k4",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer High Reliability FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "GN Resound Vivia FW:10.21.2.1 via App iPhone 12",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!K4; transmitter K1; receiver A4; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--b5",
   "technology": "Auracast",
   "system": "Starkey TV-Streamer FW: not reported",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!B5; transmitter B1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--c5",
   "technology": "Auracast",
   "system": "Opus Auragate FW:2.1.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!C5; transmitter C1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--d5",
   "technology": "Auracast",
   "system": "Moor Moer SoundLinker FW:5.2.2",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!D5; transmitter D1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--e5",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer Low Latency FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!E5; transmitter E1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--f5",
   "technology": "Auracast",
   "system": "GN TV-Streamer + FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!F5; transmitter F1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--g5",
   "technology": "Auracast",
   "system": "Bettear B-CASTER FW:1.0.3",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!G5; transmitter G1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--h5",
   "technology": "Auracast",
   "system": "Listen Auri TX2N FW:1.5",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!H5; transmitter H1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--i5",
   "technology": "Auracast",
   "system": "GN MultiMic+ FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!I5; transmitter I1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j5",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Moer Moor Duo #21 FW:3.7.0 via BT Menu on Samsung Galaxy Z Flip 5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J5; transmitter J1; receiver A5; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--c6",
   "technology": "Auracast",
   "system": "Opus Auragate FW:2.1.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!C6; transmitter C1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--d6",
   "technology": "Auracast",
   "system": "Moor Moer SoundLinker FW:5.2.2",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!D6; transmitter D1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--e6",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer Low Latency FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!E6; transmitter E1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--f6",
   "technology": "Auracast",
   "system": "GN TV-Streamer + FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!F6; transmitter F1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--g6",
   "technology": "Auracast",
   "system": "Bettear B-CASTER FW:1.0.3",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!G6; transmitter G1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--i6",
   "technology": "Auracast",
   "system": "GN MultiMic+ FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!I6; transmitter I1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j6",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Bettear RTX FW:1.0.1 & 1.0.3",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J6; transmitter J1; receiver A6; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--b7",
   "technology": "Auracast",
   "system": "Starkey TV-Streamer FW: not reported",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 2/5: reception throughout the hall with occasional dropouts or low audio artefacts or distortion.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!B7; transmitter B1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--c7",
   "technology": "Auracast",
   "system": "Opus Auragate FW:2.1.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!C7; transmitter C1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--d7",
   "technology": "Auracast",
   "system": "Moor Moer SoundLinker FW:5.2.2",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!D7; transmitter D1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--e7",
   "technology": "Auracast",
   "system": "Arendi TV-Streamer Low Latency FW:0.8.1",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 3/5: reception throughout the hall; occasional dropouts or slight jitter or distortion from about 10 m, increasing from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!E7; transmitter E1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--f7",
   "technology": "Auracast",
   "system": "GN TV-Streamer + FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!F7; transmitter F1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--g7",
   "technology": "Auracast",
   "system": "Bettear B-CASTER FW:1.0.3",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!G7; transmitter G1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--h7",
   "technology": "Auracast",
   "system": "Listen Auri TX2N FW:1.5",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!H7; transmitter H1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--i7",
   "technology": "Auracast",
   "system": "GN MultiMic+ FW:1.0.2.7",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!I7; transmitter I1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results. Consumer or personal transmitter included only as evidence about the shared Auracast reception path.",
   "source_summary_inclusion": "included",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j7",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 5/5: dropouts and audio artefacts or distortion from as early as 5 m; frequent dropouts and severe artefacts beyond that, with connection interruptions or extreme distortion or dropouts from around mid-hall.",
   "receiver": "Humantechnik earis MAX Headphone FW: 4.4.0",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J7; transmitter J1; receiver A7; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "included",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--h8",
   "technology": "Auracast",
   "system": "Listen Auri TX2N FW:1.5",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 1/5: reception throughout the hall with no or very few dropouts and minimal audio artefacts or distortion.",
   "receiver": "Listen Auri RX1 FW:1.5",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!H8; transmitter H1; receiver A8; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "excluded",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-compat--j9",
   "technology": "Auracast",
   "system": "Williams Infinium FW:1.4.0",
   "setting": "Indoor hall without significant event interference; BERNEXPO Stage, Bern; occupancy not quantified",
   "distance_or_area": "75 x 57 m hall; 18 m ceiling",
   "outcome": "Rating 4/5: reception throughout the hall; dropouts and audio artefacts or distortion from about 5-10 m, becoming frequent and significant around mid-hall (about 40 m); connection interruptions may require manual reconnection.",
   "receiver": "Williams Infinium Rx FW: not reported",
   "evidence_type": "listening test",
   "test_date": "2025-09-25",
   "source_date": "2025-10-06",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-compat",
   "source_locator": "original.xlsx: Signal Reception - Rating!J9; transmitter J1; receiver A9; scale A13:A17; Signal Reception - Test Setup!B2:B9",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; no manufacturer funding, test products lent free by manufacturers)",
   "conditions": "Analog pink-noise input from NTI MR-PRO; walk test monitoring dropouts, jitter and distortion; transmitter placed for greatest distance rather than central coverage; 53 scored pairs.",
   "limitations": "One hall and one deliberately distant transmitter position; subjective listening grades, not packet-loss measurements or measured maximum distances. Other rooms and firmware may give different results.",
   "source_summary_inclusion": "excluded",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a1",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Main committee room 1R0",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A1",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a2",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1R0 gallery",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "20-80% of area",
   "outcome": "Partial coverage grade: suitable signal level over 20-80% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A2",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a3",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1R1",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A3",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a4",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1R2",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A4",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a5",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1R3",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A5",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a6",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1R4",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "less than 20% of area",
   "outcome": "Marginal coverage grade: suitable signal level over less than 20% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A6",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a7",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 2R1",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "less than 20% of area",
   "outcome": "Marginal coverage grade: suitable signal level over less than 20% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A7",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a8",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 2R2",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A8",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a9",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 2R3",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A9",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a10",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1S2",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "less than 20% of area",
   "outcome": "Marginal coverage grade: suitable signal level over less than 20% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A10",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a11",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1S3",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A11",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a12",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 1S4",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A12",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a13",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 2S1",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A13",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a14",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 2S2",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A14",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a15",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Committee room 2S3",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A15",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a16",
   "technology": "Hearing loops",
   "system": "Installed induction loop: House of Representatives floor",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A16",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a17",
   "technology": "Hearing loops",
   "system": "Installed induction loop: House of Representatives gallery, second west",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A17",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a18",
   "technology": "Hearing loops",
   "system": "Installed induction loop: House of Representatives gallery, first west",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A18",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a19",
   "technology": "Hearing loops",
   "system": "Installed induction loop: House of Representatives gallery, first north",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A19",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a20",
   "technology": "Hearing loops",
   "system": "Installed induction loop: House of Representatives gallery, first south",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A20",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a21",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Senate gallery, second east",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A21",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a22",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Senate gallery, second north",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "20-80% of area",
   "outcome": "Partial coverage grade: suitable signal level over 20-80% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A22",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a23",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Senate gallery, second south",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A23",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a24",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Senate gallery, first east",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A24",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a25",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Senate gallery, first north",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A25",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a26",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Senate gallery, first south",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A26",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a27",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Theatre",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "20-80% of area",
   "outcome": "Partial coverage grade: suitable signal level over 20-80% of the area. Table 1 also ties its assessment to the indicated labelling.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A27",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a28",
   "technology": "Hearing loops",
   "system": "Installed induction loop: EPCR Blue Room",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% of area",
   "outcome": "Top coverage grade: suitable signal level over 80-100% of the area.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A28; Appendix A28, printed p. 39",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year. Appendix A28 reports above-normal hum from television studio lamps and mains wiring, rising sharply in the northeast corner.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a29",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Government party room",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A29",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a30",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Opposition party room",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "coverage percentage not reported",
   "outcome": "Lowest grade: low base signal level and excessive attenuation; the audit assigns no percentage to this grade.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A30",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31 areas in one building; amplifier adjusted before grid measurements; target 0 dB peak down to -6 dB, desired signal-to-noise 45 dB and minimum 25 dB.",
   "limitations": "First-draft in-house audit. Grades describe signal coverage after adjustment; they do not establish full performance against the loop standard. No frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "aph-2008-parliament-loop-audit--a31",
   "technology": "Hearing loops",
   "system": "Installed induction loop: Cabinet room",
   "setting": "Parliament House, Australia; occupancy during measurement not reported",
   "distance_or_area": "80-100% category in Table 1; room only partially tested",
   "outcome": "Table 1 assigns the top coverage grade, defined as 80-100%. Appendix A31 says the room was only partially tested and refers to earlier commissioning by T4.",
   "receiver": "LM Audio ILM12 calibrated induction loop monitor",
   "evidence_type": "field measurement",
   "test_date": "not reported",
   "source_date": "2008-12",
   "source_date_basis": "cover month; history also gives 2008-11-17",
   "source_id": "aph-2008-parliament-loop-audit",
   "source_locator": "PDF printed pp. 9-11, sections 3.1-3.5, Table 1 row A31; Appendix A31, printed p. 42",
   "funding_detail": "Government (an in-house audit by the Australian Parliament's Department of Parliamentary Services of the hearing loops it maintains in Parliament House, carried out by its own broadcasting support staff)",
   "conditions": "31-area audit. This room was only partially tested with low-level pink noise because of system integrity issues.",
   "limitations": "The top grade must not be treated as a complete measured coverage result from this audit. Appendix A31 refers to earlier commissioning by T4 without its date or measurements. No full frequency-response test is reported; background noise used C weighting. Measurement dates are not stated; 2008 is the report year.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "pro-audito-2025-theatre-aarau--all-seats",
   "technology": "Auracast",
   "system": "Listen Technologies Auri; one transmitter",
   "setting": "Theatre trial installation; Alte Reithalle, Bühne Aarau; audience count not reported",
   "distance_or_area": "about 22 x 80 m hall; all visitor seats",
   "outcome": "Reception reported at every visitor seat.",
   "receiver": "GN ReSound Nexia hearing aids and receivers with neckloops; no receiver-specific coverage map",
   "evidence_type": "field observation",
   "test_date": "not reported",
   "source_date": "2025-03-17",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-theatre-aarau",
   "source_locator": "Article: Das Ergebnis: Grundsätzlich positiv; Latenz",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Single transmitter in roof structure approximately at the centre of the room.",
   "limitations": "One room and one hearing-aid model. Occupied operation with hundreds of phones was not tested. Room dimensions are not a transmitter-to-receiver distance.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2025-pilatus-arena--match-visit",
   "technology": "Auracast",
   "system": "Four Listen Auri TX2N transmitters",
   "setting": "Occupied arena during a match; Pilatus Arena, Kriens; attendance not reported",
   "distance_or_area": "tested positions not mapped; distance and full-bowl coverage not reported",
   "outcome": "Testers judged reception, audio quality and intelligibility faultless with the tested personal devices and loan receivers.",
   "receiver": "Starkey Edge, GN ReSound Vivia, Oticon Intent; Humantechnik earisMAX, JBL Tour Pro 3; Auri RX1 loan receivers with neckloops",
   "evidence_type": "field observation",
   "test_date": "2025-11",
   "source_date": "2025-11-03",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2025-pilatus-arena",
   "source_locator": "Article introduction; Roaming; So verlief der Test",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; test devices were lent free by their manufacturers or owned by participants)",
   "conditions": "Three hearing-aid models, two headphone models and loan receivers; devices lent free by makers or personally owned. All four transmitters used one broadcast name.",
   "limitations": "One visit, no participant count, seat map or reception-rating criteria. Phones showed four identically named streams; only the system receivers were reported to switch automatically.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-venucast-test--short-range-test",
   "technology": "Auracast",
   "system": "Avantree Venucast Oasis Aura",
   "setting": "Short test; room and occupancy not reported",
   "distance_or_area": "not reported",
   "outcome": "Range judged comparable to professional transmitters.",
   "receiver": "AuraClip receivers and hearing aids in the test; no receiver-specific range results",
   "evidence_type": "field observation",
   "test_date": "not reported",
   "source_date": "2026-07-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-venucast-test",
   "source_locator": "Article introduction; Was uns gefallen hat",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association; test units supplied free by the manufacturer, Pro Audito not paid)",
   "conditions": "One transmitter and three AuraClip receivers supplied free by Avantree; unpaid test. Hearing-aid count and models not stated.",
   "limitations": "No distance, comparison models, range protocol or firmware given.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-outdoor--auracast-5m",
   "technology": "Auracast",
   "system": "Auracast transmitter; model not reported",
   "setting": "Outdoor crowd; Helvetiaplatz, Zurich; about 2,000 people",
   "distance_or_area": "up to about 5 m in front of transmitter",
   "outcome": "Reliable reception for virtually all tested receivers within this distance; this is not a maximum for every individual receiver.",
   "receiver": "Authors' hearing aids and receivers; models not reported",
   "evidence_type": "field observation",
   "test_date": "2026-05-02",
   "source_date": "2026-09-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-outdoor",
   "source_locator": "PDF p. 3, Finding paragraph",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Event area about 30 x 20 m; Auracast transmitter about 2 m high beside left main loudspeaker, facing front to back; buildings at some distance.",
   "limitations": "One event and transmitter position; hearing-aid and receiver models, receiver sample size, transmitter model, power and firmware not stated; translated report.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-outdoor--auracast-8m-body",
   "technology": "Auracast",
   "system": "Auracast transmitter; model not reported",
   "setting": "Outdoor crowd; Helvetiaplatz, Zurich; about 2,000 people; own body blocks line of sight",
   "distance_or_area": "about 8 m",
   "outcome": "No reception when the tester's body blocked the transmitter-to-receiver path.",
   "receiver": "Chest-worn receiver; model not reported",
   "evidence_type": "field observation",
   "test_date": "2026-05-02",
   "source_date": "2026-09-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-outdoor",
   "source_locator": "PDF p. 3, image description and result",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Event area about 30 x 20 m; Auracast transmitter about 2 m high beside left main loudspeaker, facing front to back; buildings at some distance.",
   "limitations": "One event and transmitter position; hearing-aid and receiver models, receiver sample size, transmitter model, power and firmware not stated; translated report.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-outdoor--auracast-empty",
   "technology": "Auracast",
   "system": "Auracast transmitter; model not reported",
   "setting": "Empty outdoor square; Helvetiaplatz, Zurich",
   "distance_or_area": "test distance not reported; event area about 30 x 20 m",
   "outcome": "The empty-space check did not reveal the later crowd limitation; receiver position at belt, chest or ears made no difference in that check.",
   "receiver": "Belt/chest receivers, hearing aids and headphones; models not reported",
   "evidence_type": "field observation",
   "test_date": "not reported",
   "source_date": "2026-09-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-outdoor",
   "source_locator": "PDF pp. 2-3, Lack of reflections and Finding",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Event area about 30 x 20 m; Auracast transmitter about 2 m high beside left main loudspeaker, facing front to back; buildings at some distance.",
   "limitations": "Pre-event functional check without a distance or mapped coverage; exact test date not stated.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-outdoor--fm",
   "technology": "RF/FM",
   "system": "Existing FM system; model not reported",
   "setting": "Outdoor crowd; Helvetiaplatz, Zurich; about 2,000 people",
   "distance_or_area": "tested extent not reported; event area about 30 x 20 m",
   "outcome": "Stable radio transmission; telecoil users heard magnetic interference from nearby tram overhead lines.",
   "receiver": "FM receivers with inductive neckloops",
   "evidence_type": "field observation",
   "test_date": "2026-05-02",
   "source_date": "2026-09-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-outdoor",
   "source_locator": "PDF p. 4, FM system",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Event area about 30 x 20 m; around 2,000 people; three systems operated in parallel.",
   "limitations": "One event; device models, receiver sample size and firmware not stated; translated report. No mapped coverage or device-specific reception results.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-outdoor--5g",
   "technology": "Shared",
   "system": "Accessify internet streaming over 5G",
   "setting": "Outdoor crowd; Helvetiaplatz, Zurich; about 2,000 people",
   "distance_or_area": "entire venue; about 30 x 20 m event area",
   "outcome": "Uninterrupted reception over the cellular internet path across the venue; measured delay about 360 ms.",
   "receiver": "Smartphones; models not reported",
   "evidence_type": "field observation",
   "test_date": "2026-05-02",
   "source_date": "2026-09-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-outdoor",
   "source_locator": "PDF p. 4, Accessify and latency table",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Event area about 30 x 20 m; around 2,000 people; three systems operated in parallel.",
   "limitations": "One event; device models, receiver sample size and firmware not stated; translated report. No mapped coverage or device-specific reception results.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system; cellular streaming",
   "funding": "Independent"
  },
  {
   "result_id": "pro-audito-2026-outdoor--phone-hearing-aid",
   "technology": "Shared",
   "system": "Phone-to-hearing-aid Bluetooth path after Accessify 5G reception",
   "setting": "Outdoor crowd; Helvetiaplatz, Zurich; about 2,000 people; phone in back pocket",
   "distance_or_area": "body-obstructed personal link; distance not reported",
   "outcome": "Occasional interruptions between smartphone and hearing aid despite stable internet reception; the reported problem did not occur with in-ear headphones.",
   "receiver": "Hearing aids compared with in-ear headphones; models not reported",
   "evidence_type": "field observation",
   "test_date": "2026-05-02",
   "source_date": "2026-09-16",
   "source_date_basis": "publication date",
   "source_id": "pro-audito-2026-outdoor",
   "source_locator": "PDF p. 4, Limitations in the device connection",
   "funding_detail": "Independent (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Event area about 30 x 20 m; around 2,000 people; three systems operated in parallel.",
   "limitations": "One event; device models, receiver sample size and firmware not stated; translated report. No mapped coverage or device-specific reception results.",
   "source_summary_inclusion": "not applicable",
   "scope": "shared-path comparison",
   "funding": "Independent"
  },
  {
   "result_id": "london-assembly-2016-sensory-travel--routemaster-seats",
   "technology": "Hearing loops",
   "system": "Installed loop on a new Routemaster bus; model not reported",
   "setting": "Occupied bus journey in London; passenger load not reported",
   "distance_or_area": "priority seats near middle door; no dimensions reported",
   "outcome": "Audible only in the priority seats nearest the middle door, not those across the aisle; unpleasant buzz particularly behind the driver's cab.",
   "receiver": "Two hearing-aid users; device models not reported",
   "evidence_type": "field observation",
   "test_date": "2016-02-25",
   "source_date": "2016-03-18",
   "source_date_basis": "publication date",
   "source_id": "london-assembly-2016-sensory-travel",
   "source_locator": "Report printed pp. 6-7 (site-visit sample) and p. 20 (observations); p. 27, Site visit (date)",
   "funding_detail": "Government (London Assembly, the elected body that scrutinises the Mayor of London and Transport for London)",
   "conditions": "Committee chair accompanied two hearing-aid users on one bus journey.",
   "limitations": "One observed journey with no field-strength measurements; findings cannot represent the bus network.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Government"
  },
  {
   "result_id": "auri-2025-coverage-guide--30-40m",
   "technology": "Auracast",
   "system": "Auri TX2N / TX2N-D",
   "setting": "not reported",
   "distance_or_area": "about 30-40 m in any direction",
   "outcome": "Listen Technologies and Ampetronic state this reach for received signal strength of -70 dBm.",
   "receiver": "Auri RX1",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2025-04-17",
   "source_date_basis": "printed document code 20250417 and PDF creation date",
   "source_id": "auri-2025-coverage-guide",
   "source_locator": "PDF p. 1, General Coverage",
   "funding_detail": "Manufacturer (Listen Technologies and Ampetronic)",
   "conditions": "Received signal-strength threshold stated; transmit power and test venue not reported.",
   "limitations": "Manufacturer estimate; layout and audience density affect performance. The guide's empty-room walk-test advice does not establish the conditions behind this range.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "opus-2025-auragate-datasheet--150m",
   "technology": "Auracast",
   "system": "Opus AuraGate",
   "setting": "Open range; occupancy not reported",
   "distance_or_area": "150 m",
   "outcome": "Opus labels this an open-range measurement.",
   "receiver": "not reported",
   "evidence_type": "manufacturer-reported measurement",
   "test_date": "not reported",
   "source_date": "2025-11",
   "source_date_basis": "upload-folder month; document undated",
   "source_id": "opus-2025-auragate-datasheet",
   "source_locator": "PDF technical specifications: Mesured range",
   "funding_detail": "Manufacturer (Opus Technologies)",
   "conditions": "not reported",
   "limitations": "No method, receiver, firmware, sample size or power variant identified; EU and US variants have different transmit powers.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "williams-av-2026-infinium-manual--100m",
   "technology": "Auracast",
   "system": "Williams AV Infinium BA T1",
   "setting": "Open space; occupancy not reported",
   "distance_or_area": "up to 100 m (328 ft)",
   "outcome": "Williams AV states this open-space range with its own receiver.",
   "receiver": "Williams AV Infinium BA R1",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2026",
   "source_date_basis": "manual copyright year",
   "source_id": "williams-av-2026-infinium-manual",
   "source_locator": "Manual: BA T1 Transmitter; Specifications: Range",
   "funding_detail": "Manufacturer (Williams AV)",
   "conditions": "not reported",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "phonak-2026-eon-connectivity--211m",
   "technology": "Auracast",
   "system": "Auracast transmitter; model not reported",
   "setting": "not reported",
   "distance_or_area": "up to 211 m",
   "outcome": "Phonak reports reception at this distance in its own testing.",
   "receiver": "Phonak Audéo EON",
   "evidence_type": "manufacturer-reported measurement",
   "test_date": "not reported",
   "source_date": "2026-09-17",
   "source_date_basis": "publication date; metadata modified 2026-09-21",
   "source_id": "phonak-2026-eon-connectivity",
   "source_locator": "Article: Auracast broadcast audio, paragraph beginning Range and compatibility",
   "funding_detail": "Manufacturer (Sonova / Phonak)",
   "conditions": "not reported",
   "limitations": "Unpublished manufacturer comparison with three unnamed hearing aids; no conditions, protocol, sample size, transmitter or firmware stated.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "bettear-rtx--50m",
   "technology": "Auracast",
   "system": "Bettear RTX in transmitter mode",
   "setting": "not reported",
   "distance_or_area": "up to 50 m",
   "outcome": "Bettear states this coverage at 20 dBm.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "undated",
   "source_date_basis": "undated source",
   "source_id": "bettear-rtx",
   "source_locator": "Product features: Wide-area coverage",
   "funding_detail": "Manufacturer (Bettear, maker of the RTX)",
   "conditions": "20 dBm stated; no receiver or test setting.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "ampetronic-listen-2025-hlaa-presentation--100m",
   "technology": "Auracast",
   "system": "Auracast; no model tied to the range statement",
   "setting": "not reported",
   "distance_or_area": "over 100 m",
   "outcome": "Ampetronic and Listen Technologies give this generic range in their presentation.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2025-12-03",
   "source_date_basis": "presentation file name and PDF creation date",
   "source_id": "ampetronic-listen-2025-hlaa-presentation",
   "source_locator": "Slide: What is Auracast?",
   "funding_detail": "Manufacturer (Ampetronic and Listen Technologies, both owned by Allvida, which between them sell hearing loops, the Auri Auracast system and RF, infrared and Wi-Fi systems; presented by Listen's chief of staff and its channel marketing director)",
   "conditions": "not reported",
   "limitations": "Manufacturer presentation with no method, room, receiver or power behind the number.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "bluetooth-sig-2025-range-handout--100m",
   "technology": "Auracast",
   "system": "Mains-powered public Auracast transmitter; model not reported",
   "setting": "not reported",
   "distance_or_area": "about 100 m",
   "outcome": "Bluetooth SIG states this approximate broadcast range.",
   "receiver": "not reported",
   "evidence_type": "trade-body claim",
   "test_date": "not reported",
   "source_date": "2025-07-28",
   "source_date_basis": "PDF creation date; handout undated",
   "source_id": "bluetooth-sig-2025-range-handout",
   "source_locator": "One-page handout: Auracast broadcast audio",
   "funding_detail": "Trade body (Bluetooth SIG marketing material; the SIG is an industry association funded by its member companies and owns the Auracast trademark)",
   "conditions": "not reported",
   "limitations": "No test conditions, receiver, power or room; the separate paired-audio comparison is outside this table.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "bluetooth-sig-2025-qr-paper--alice-tully",
   "technology": "Auracast",
   "system": "Single Auracast transmitter; model not reported",
   "setting": "Alice Tully Hall, Lincoln Center; occupancy not reported",
   "distance_or_area": "all 1,085 seats",
   "outcome": "Bluetooth SIG reports that one transmitter covered all seats at a demonstration.",
   "receiver": "not reported",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "2025-02-17",
   "source_date_basis": "printed revision date",
   "source_id": "bluetooth-sig-2025-qr-paper",
   "source_locator": "Paper: paragraph describing Lincoln Center / Alice Tully Hall",
   "funding_detail": "Trade body (Bluetooth SIG marketing material; the SIG is an industry association funded by its member companies and owns the Auracast trademark)",
   "conditions": "not reported",
   "limitations": "No method, distance, receiver, demonstration date or occupied coverage map.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "graf-2026--30m",
   "technology": "Auracast",
   "system": "Auracast transmitters in theatre and event practice",
   "setting": "Theatres and event venues; no specific test site",
   "distance_or_area": "about 30 m",
   "outcome": "Graf gives this practical range and says a full room with heavy Wi-Fi can shorten it considerably.",
   "receiver": "not reported",
   "evidence_type": "expert estimate",
   "test_date": "not reported",
   "source_date": "2026-09",
   "source_date_basis": "issue month",
   "source_id": "graf-2026",
   "source_locator": "Article: Reach and positioning",
   "funding_detail": "Nonprofit advocacy (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "not reported",
   "limitations": "Expert guidance without measurement method, individual devices or sample size.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Nonprofit advocacy"
  },
  {
   "result_id": "pro-audito-2025-operator-guidance--20-30m",
   "technology": "Auracast",
   "system": "Auracast transmitter rated at 20 dBm",
   "setting": "Extreme conditions; no measured site identified",
   "distance_or_area": "about 20-30 m",
   "outcome": "Pro Audito estimates that nominal 100 m range could shrink to this distance under extreme conditions.",
   "receiver": "not reported",
   "evidence_type": "expert estimate",
   "test_date": "not reported",
   "source_date": "2025-02-17",
   "source_date_basis": "displayed page date; later revisions undated",
   "source_id": "pro-audito-2025-operator-guidance",
   "source_locator": "Article: Installation und Positionierung von Auracast-Sendern",
   "funding_detail": "Nonprofit advocacy (Pro Audito Schweiz, Swiss hearing-loss association)",
   "conditions": "Estimate refers to data sheets for 20 dBm / 100 mW transmitters.",
   "limitations": "No controlled measurement; page has a displayed publication date but also later material without a revision date.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Nonprofit advocacy"
  },
  {
   "result_id": "opus-2025-auraloop--loop-page",
   "technology": "Hearing loops",
   "system": "Opus AuraLoop",
   "setting": "Desk/counter unit; test setting not reported",
   "distance_or_area": "3 m",
   "outcome": "Opus states this range on its product page.",
   "receiver": "Telecoil device; model not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2025-04-18",
   "source_date_basis": "page last-update date",
   "source_id": "opus-2025-auraloop",
   "source_locator": "Product page: Technical specifications",
   "funding_detail": "Manufacturer (Opus Technologies)",
   "conditions": "not reported",
   "limitations": "Manufacturer claim without protocol. For the loop path, the linked manual instead states 1.10 m.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "opus-2025-auraloop--auracast-page",
   "technology": "Auracast",
   "system": "Opus AuraLoop",
   "setting": "Free field; occupancy not reported",
   "distance_or_area": "30 m",
   "outcome": "Opus states this range on its product page.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2025-04-18",
   "source_date_basis": "page last-update date",
   "source_id": "opus-2025-auraloop",
   "source_locator": "Product page: Technical specifications",
   "funding_detail": "Manufacturer (Opus Technologies)",
   "conditions": "Product page lists Bluetooth transmit power of 3 dBm.",
   "limitations": "Manufacturer claim without a test protocol, receiver or reception threshold.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "opus-2025-auraloop--loop-manual",
   "technology": "Hearing loops",
   "system": "Opus AuraLoop",
   "setting": "Desk/counter unit; test setting not reported",
   "distance_or_area": "1.10 m",
   "outcome": "Opus states this magnetic-field range in its installation manual.",
   "receiver": "Telecoil device; model not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2025-03",
   "source_date_basis": "linked manual version month",
   "source_id": "opus-2025-auraloop",
   "source_locator": "Linked manual V1.0: printed p. 10, Portée du champ magnétique; version p. 20",
   "funding_detail": "Manufacturer (Opus Technologies)",
   "conditions": "Manual V1.0, March 2025, associated firmware v1.2.0.",
   "limitations": "No protocol or field-strength threshold at the quoted distance; product page instead states 3 m.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "williams-av-2024-ir-t3-manual--rx22-4",
   "technology": "Infrared",
   "system": "Williams AV IR T3",
   "setting": "Indoor coverage pattern; occupancy not reported",
   "distance_or_area": "up to 32,000 sq ft (2,972 m²)",
   "outcome": "Williams AV states this single-channel coverage.",
   "receiver": "Williams AV RX22-4 handheld",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2024-11-06",
   "source_date_basis": "PDF creation date; manual copyright 2024",
   "source_id": "williams-av-2024-ir-t3-manual",
   "source_locator": "Manual: Determine Coverage Area; Coverage Area specifications",
   "funding_detail": "Manufacturer (Williams AV, maker of the SoundPlus IR T3 transmitter described)",
   "conditions": "One channel; reflections, room construction and sunlight can change the pattern.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "williams-av-2024-ir-t3-manual--rx20",
   "technology": "Infrared",
   "system": "Williams AV IR T3",
   "setting": "Indoor coverage pattern; occupancy not reported",
   "distance_or_area": "up to 19,000 sq ft (1,765 m²)",
   "outcome": "Williams AV states this single-channel coverage.",
   "receiver": "Williams AV RX20 stethoset",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2024-11-06",
   "source_date_basis": "PDF creation date; manual copyright 2024",
   "source_id": "williams-av-2024-ir-t3-manual",
   "source_locator": "Manual: Determine Coverage Area; Coverage Area specifications",
   "funding_detail": "Manufacturer (Williams AV, maker of the SoundPlus IR T3 transmitter described)",
   "conditions": "One channel; reflections, room construction and sunlight can change the pattern.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2022-lt82-ir-manual--lr42-44-1ch",
   "technology": "Infrared",
   "system": "Listen LT-82 with one LA-140 radiator",
   "setting": "Line-of-sight coverage; occupancy not reported",
   "distance_or_area": "about 10,000 sq ft (929 m²)",
   "outcome": "Listen Technologies states this coverage for one channel.",
   "receiver": "Listen LR-42 / LR-44",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2022-09-26",
   "source_date_basis": "file name and PDF creation date",
   "source_id": "listen-2022-lt82-ir-manual",
   "source_locator": "Manual printed p. 7, Design Guide: Number of radiators and location",
   "funding_detail": "Manufacturer (Listen Technologies, maker of the ListenIR transmitter and radiator described)",
   "conditions": "One radiator; one channel; receiver family changes the stated area.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2022-lt82-ir-manual--lr42-44-2ch",
   "technology": "Infrared",
   "system": "Listen LT-82 with one LA-140 radiator",
   "setting": "Line-of-sight coverage; occupancy not reported",
   "distance_or_area": "about 5,000 sq ft (465 m²)",
   "outcome": "Listen Technologies states this coverage for two channels.",
   "receiver": "Listen LR-42 / LR-44",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2022-09-26",
   "source_date_basis": "file name and PDF creation date",
   "source_id": "listen-2022-lt82-ir-manual",
   "source_locator": "Manual printed p. 7, Design Guide: Number of radiators and location",
   "funding_detail": "Manufacturer (Listen Technologies, maker of the ListenIR transmitter and radiator described)",
   "conditions": "One radiator; two channels; receiver family changes the stated area.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2022-lt82-ir-manual--lr42-44-4ch",
   "technology": "Infrared",
   "system": "Listen LT-82 with one LA-140 radiator",
   "setting": "Line-of-sight coverage; occupancy not reported",
   "distance_or_area": "about 2,500 sq ft (232 m²)",
   "outcome": "Listen Technologies states this coverage for four channels.",
   "receiver": "Listen LR-42 / LR-44",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2022-09-26",
   "source_date_basis": "file name and PDF creation date",
   "source_id": "listen-2022-lt82-ir-manual",
   "source_locator": "Manual printed p. 7, Design Guide: Number of radiators and location",
   "funding_detail": "Manufacturer (Listen Technologies, maker of the ListenIR transmitter and radiator described)",
   "conditions": "One radiator; four channels; receiver family changes the stated area.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2022-lt82-ir-manual--lr4200-5200-1ch",
   "technology": "Infrared",
   "system": "Listen LT-82 with one LA-140 radiator",
   "setting": "Line-of-sight coverage; occupancy not reported",
   "distance_or_area": "about 40,000 sq ft (3,716 m²)",
   "outcome": "Listen Technologies states this coverage for one channel.",
   "receiver": "Listen LR-4200-IR / LR-5200-IR",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2022-09-26",
   "source_date_basis": "file name and PDF creation date",
   "source_id": "listen-2022-lt82-ir-manual",
   "source_locator": "Manual printed p. 7, Design Guide: Number of radiators and location",
   "funding_detail": "Manufacturer (Listen Technologies, maker of the ListenIR transmitter and radiator described)",
   "conditions": "One radiator; one channel; receiver family changes the stated area.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "sennheiser-szi-1015--400m2",
   "technology": "Infrared",
   "system": "Sennheiser SZI 1015",
   "setting": "not reported",
   "distance_or_area": "up to 400 m²",
   "outcome": "Sennheiser states this radiator coverage.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "undated",
   "source_date_basis": "undated source",
   "source_id": "sennheiser-szi-1015",
   "source_locator": "Product description and features",
   "funding_detail": "Manufacturer (Sennheiser, maker of the infrared radiator described)",
   "conditions": "2 W radiator; channel configuration for area figure not stated.",
   "limitations": "Manufacturer catalogue claim without test conditions. Archived page marks the product as no longer available.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2010-72-vs-216--72-stationary",
   "technology": "RF/FM",
   "system": "Listen stationary FM transmitter at 72 MHz",
   "setting": "not reported",
   "distance_or_area": "305 m (1,000 ft)",
   "outcome": "Listen Technologies gives this range for its own transmitter configuration.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2010-02-24",
   "source_date_basis": "publication date; metadata modified 2021-06-04",
   "source_id": "listen-2010-72-vs-216",
   "source_locator": "Article: Transmission Range; Cable Length for cable-loss example",
   "funding_detail": "Manufacturer (Listen Technologies, which sells the FM systems compared here as well as infrared, hearing loop, Wi-Fi and Auracast assistive listening products)",
   "conditions": "Dipole antenna.",
   "limitations": "No independent test data or receiver specified. The article says the stationary range doubles although its numerical examples triple it.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2010-72-vs-216--216-stationary",
   "technology": "RF/FM",
   "system": "Listen stationary FM transmitter at 216 MHz",
   "setting": "not reported",
   "distance_or_area": "up to 914 m (3,000 ft)",
   "outcome": "Listen Technologies gives this range for its own transmitter configuration.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2010-02-24",
   "source_date_basis": "publication date; metadata modified 2021-06-04",
   "source_id": "listen-2010-72-vs-216",
   "source_locator": "Article: Transmission Range; Cable Length for cable-loss example",
   "funding_detail": "Manufacturer (Listen Technologies, which sells the FM systems compared here as well as infrared, hearing loop, Wi-Fi and Auracast assistive listening products)",
   "conditions": "Dipole antenna; line of sight.",
   "limitations": "No independent test data or receiver specified. The article says the stationary range doubles although its numerical examples triple it.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2010-72-vs-216--72-portable",
   "technology": "RF/FM",
   "system": "Listen LT-700 portable FM transmitter at 72 MHz",
   "setting": "not reported",
   "distance_or_area": "45.7 m (150 ft)",
   "outcome": "Listen Technologies gives this range for its own transmitter configuration.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2010-02-24",
   "source_date_basis": "publication date; metadata modified 2021-06-04",
   "source_id": "listen-2010-72-vs-216",
   "source_locator": "Article: Transmission Range; Cable Length for cable-loss example",
   "funding_detail": "Manufacturer (Listen Technologies, which sells the FM systems compared here as well as infrared, hearing loop, Wi-Fi and Auracast assistive listening products)",
   "conditions": "Portable operation; antenna details not given.",
   "limitations": "No independent test data or receiver specified. The article says the stationary range doubles although its numerical examples triple it.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2010-72-vs-216--216-portable",
   "technology": "RF/FM",
   "system": "Listen LT-700 portable FM transmitter at 216 MHz",
   "setting": "not reported",
   "distance_or_area": "45.7 m (150 ft)",
   "outcome": "Listen Technologies gives this range for its own transmitter configuration.",
   "receiver": "not reported",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2010-02-24",
   "source_date_basis": "publication date; metadata modified 2021-06-04",
   "source_id": "listen-2010-72-vs-216",
   "source_locator": "Article: Transmission Range; Cable Length for cable-loss example",
   "funding_detail": "Manufacturer (Listen Technologies, which sells the FM systems compared here as well as infrared, hearing loop, Wi-Fi and Auracast assistive listening products)",
   "conditions": "Portable operation; antenna details not given.",
   "limitations": "No independent test data or receiver specified. The article says the stationary range doubles although its numerical examples triple it.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "listen-2010-72-vs-216--216-cable-loss",
   "technology": "RF/FM",
   "system": "Listen LT-800-216 stationary FM transmitter",
   "setting": "not reported",
   "distance_or_area": "1,500 ft after cable loss; 3,000 ft baseline",
   "outcome": "Listen Technologies gives this range for its own transmitter configuration.",
   "receiver": "not reported",
   "evidence_type": "manufacturer estimate",
   "test_date": "not reported",
   "source_date": "2010-02-24",
   "source_date_basis": "publication date; metadata modified 2021-06-04",
   "source_id": "listen-2010-72-vs-216",
   "source_locator": "Article: Transmission Range; Cable Length for cable-loss example",
   "funding_detail": "Manufacturer (Listen Technologies, which sells the FM systems compared here as well as infrared, hearing loop, Wi-Fi and Auracast assistive listening products)",
   "conditions": "100 ft RG-58 antenna cable; source describes an expected reduction.",
   "limitations": "No independent test data or receiver specified. The article says the stationary range doubles although its numerical examples triple it.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "williams-av-2025-digi-wave-400-manual--900ft",
   "technology": "RF/FM",
   "system": "Williams AV Digi-Wave 400 series",
   "setting": "not reported",
   "distance_or_area": "up to 900 ft (274 m)",
   "outcome": "Williams AV states this range depending on environmental conditions.",
   "receiver": "Digi-Wave 400 receivers/transceivers; no specific tested pair",
   "evidence_type": "manufacturer specification",
   "test_date": "not reported",
   "source_date": "2025",
   "source_date_basis": "copyright year; PDF created 2025-11-07",
   "source_id": "williams-av-2025-digi-wave-400-manual",
   "source_locator": "Manual: specifications, Range",
   "funding_detail": "Manufacturer (Williams AV, which sells the Digi-Wave system described as well as FM, infrared, hearing loop, Wi-Fi and Auracast assistive listening products)",
   "conditions": "Proprietary 2.4 GHz digital system; hearing-assistance mode among its uses.",
   "limitations": "No independent coverage measurement or occupied-room protocol reported.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Manufacturer"
  },
  {
   "result_id": "sig-ropetackle-profile--old",
   "technology": "Infrared",
   "system": "Ageing infrared installation; model not reported",
   "setting": "Ropetackle Arts Centre; 200-seat auditorium; occupancy during assessment not reported",
   "distance_or_area": "centre of auditorium; dimensions not reported",
   "outcome": "Bluetooth SIG reports that users had to sit centrally for reliable reception.",
   "receiver": "not reported",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "undated",
   "source_date_basis": "undated source",
   "source_id": "sig-ropetackle-profile",
   "source_locator": "Article: previous-system account and new-system benefits",
   "funding_detail": "Trade body (Bluetooth SIG marketing material; the SIG is an industry association funded by its member companies and owns the Auracast trademark)",
   "conditions": "Venue staff or patron account as reported by the trade body.",
   "limitations": "No measured map, test protocol, participant count or matched comparison conditions. This describes one installation, not every system of this technology.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "sig-ropetackle-profile--new",
   "technology": "Auracast",
   "system": "Two HomeSpot BA210v2 Auracast broadcasters",
   "setting": "Ropetackle Arts Centre; 200-seat auditorium; occupancy during assessment not reported",
   "distance_or_area": "previous seating restrictions removed; dimensions not reported",
   "outcome": "Bluetooth SIG reports that Auracast coverage removed the former seating limitations.",
   "receiver": "Four headphones in the trial kit; models not reported",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "undated",
   "source_date_basis": "undated source",
   "source_id": "sig-ropetackle-profile",
   "source_locator": "Article: previous-system account and new-system benefits",
   "funding_detail": "Trade body (Bluetooth SIG marketing material; the SIG is an industry association funded by its member companies and owns the Auracast trademark)",
   "conditions": "Venue staff or patron account as reported by the trade body.",
   "limitations": "No measured map, test protocol, participant count or matched comparison conditions. This describes one installation, not every system of this technology.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "bluetooth-sig-2026-bethel-profile--old",
   "technology": "RF/FM",
   "system": "Ageing FM installation; model not reported",
   "setting": "Bethel Evangelical Lutheran Church; nave and choir loft; occupancy during assessment not reported",
   "distance_or_area": "nave and choir loft; dimensions not reported",
   "outcome": "Bluetooth SIG reports uneven reception, static and dropouts.",
   "receiver": "not reported",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "undated",
   "source_date_basis": "archived page supplies no publication date",
   "source_id": "bluetooth-sig-2026-bethel-profile",
   "source_locator": "Article: previous-system account and new-system benefits",
   "funding_detail": "Trade body (Bluetooth SIG marketing material; the SIG is an industry association funded by its member companies and owns the Auracast trademark; the transmitters are HomeSpot products)",
   "conditions": "Venue staff or patron account as reported by the trade body.",
   "limitations": "No measured map, test protocol, participant count or matched comparison conditions. This describes one installation, not every system of this technology.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "bluetooth-sig-2026-bethel-profile--new",
   "technology": "Auracast",
   "system": "HomeSpot BA210 transmitters with a transmitter-receiver repeater",
   "setting": "Bethel Evangelical Lutheran Church; nave and choir loft; occupancy during assessment not reported",
   "distance_or_area": "worship space and beyond; dimensions not reported",
   "outcome": "Bluetooth SIG reports that the team extended coverage with a repeater and resolved minor interference by moving the transmitter.",
   "receiver": "Mixed loan receivers and direct hearing aids; no device-specific coverage results",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "undated",
   "source_date_basis": "archived page supplies no publication date",
   "source_id": "bluetooth-sig-2026-bethel-profile",
   "source_locator": "Article: previous-system account and new-system benefits",
   "funding_detail": "Trade body (Bluetooth SIG marketing material; the SIG is an industry association funded by its member companies and owns the Auracast trademark; the transmitters are HomeSpot products)",
   "conditions": "Venue staff or patron account as reported by the trade body.",
   "limitations": "No measured map, test protocol, participant count or matched comparison conditions. This describes one installation, not every system of this technology.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "bihima-2026-auracast-live-theatre--old",
   "technology": "Infrared",
   "system": "Ageing infrared installation; model not reported",
   "setting": "Everyman Theatre, Cheltenham; occupancy during assessment not reported",
   "distance_or_area": "some seats, especially under dress circle; dimensions not reported",
   "outcome": "BIHIMA reports inconsistent coverage with complete dropouts in some seats.",
   "receiver": "not reported",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "2026-04-02",
   "source_date_basis": "publication date",
   "source_id": "bihima-2026-auracast-live-theatre",
   "source_locator": "Article: previous-system account and new-system benefits",
   "funding_detail": "Trade body (BIHIMA, the association of hearing instrument manufacturers in the UK and Ireland; the feature quotes staff of two theatres using Ampetronic's Auri system and credits Ampetronic with guidance during funding and installation at one of them)",
   "conditions": "Venue staff or patron account as reported by the trade body.",
   "limitations": "No measured map, test protocol, participant count or matched comparison conditions. This describes one installation, not every system of this technology.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  },
  {
   "result_id": "bihima-2026-auracast-live-theatre--new",
   "technology": "Auracast",
   "system": "Ampetronic / Listen Technologies Auri",
   "setting": "Everyman Theatre, Cheltenham; occupancy during assessment not reported",
   "distance_or_area": "auditorium seating; dimensions not reported",
   "outcome": "BIHIMA reports that audiences can sit anywhere in the auditorium with the new system.",
   "receiver": "Direct Auracast devices and loan handheld receivers; no device-specific coverage results",
   "evidence_type": "trade-body venue report",
   "test_date": "not reported",
   "source_date": "2026-04-02",
   "source_date_basis": "publication date",
   "source_id": "bihima-2026-auracast-live-theatre",
   "source_locator": "Article: previous-system account and new-system benefits",
   "funding_detail": "Trade body (BIHIMA, the association of hearing instrument manufacturers in the UK and Ireland; the feature quotes staff of two theatres using Ampetronic's Auri system and credits Ampetronic with guidance during funding and installation at one of them)",
   "conditions": "Venue staff or patron account as reported by the trade body.",
   "limitations": "No measured map, test protocol, participant count or matched comparison conditions. This describes one installation, not every system of this technology.",
   "source_summary_inclusion": "not applicable",
   "scope": "venue system",
   "funding": "Trade body"
  }
 ]
}